Dell S3048-ON EMC Solutions for Microsoft Azure Stack HCI Networking Guide
Dell S3048-ON Manual
View all Dell S3048-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell S3048-ON manual content summary:
- Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 1
Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide Abstract This guide provides Microsoft Azure Stack HCI networking deployment examples using Dell EMC Storage Spaces Direct Ready Nodes and Dell EMC Networking switches. May 2019 Dell EMC Configuration and Deployment Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 2
Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. Dell believes the information in this document is accurate as of its publication date. The information is subject to change without notice. 2 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 3
Verify license installation ...22 6.3 Factory default configuration ...23 7 Configure leaf switches ...24 7.1 General settings...25 7.2 Configure port-groups...25 7.3 Configure VLANs and VRRP...26 7.4 Configure storage interfaces ...27 7.5 Configure in-band management interfaces ...28 3 Dell EMC - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 4
...46 9.12 Create storage volumes ...46 9.13 Configure DCB on Ready Nodes...47 10 PowerShell validation commands and output ...48 10.1 Get-NetAdapter...48 10.2 Get-VMSwitch...48 10.3 Get-NetIPAddress ...49 10.4 Get-NetRoute...49 4 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 5
jumbo frame settings ...50 Dell EMC Networking Optics and Cables ...58 A.5 S2D Ready Node and management system software 58 B Port-groups...59 C Technical resources ...61 D Fabric Design Center ...62 E Support and feedback ...63 5 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 6
non-converged network). The examples in this document use a non-converged network. For more information, see the Dell EMC Solutions for Microsoft Azure Stack HCI Deployment Guide. Typographical conventions The CLI and GUI examples in this document use the following conventions: Monospace Text CLI - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 7
switch with 48xSFP28 25GbE ports, 2xQSFP28-DD ports (2x100GbE per port), and 4xQSFP28 100GbE ports. This guide uses two S5248F-ONs as leaf switches for in-band traffic. Section 2.5 contains a list of supported leaf switches for S2D. 2.2 Dell EMC Networking S5248F-ON Dell EMC Networking S3048-ON - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 8
, see Support Matrix for Dell EMC Solutions for Microsoft Azure Stack HCI. Note: Switch configuration steps in this deployment guide are specific to OS10EE. For switch configuration examples using OS9, see Sample Switch Configurations - Dell EMC Solutions for Microsoft Azure Stack HCI. 8 Dell EMC - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 9
, four S2D Ready Nodes are installed in a single rack along with two leaf switches and one OOB management switch. The devices are cabled as shown in Figure 5. S3048-ON OOB Mgmt S5248F-ON Leaf 1A 1 2 3 for the S2D environment 9 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 10
configuration is beyond the scope of this guide and is covered in Dell EMC Networking Layer 3 Leaf-Spine Deployment and Best Practices with OS10EE. Connections to leaf switches Each S5248F-ON switch has 48x25GbE ports to the leaf switches. S5248F-ON Stack ID Leaf 1A S5248F-ON Stack ID Leaf 1B GRN= - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 11
, Dell EMC part number XTY28, for each iDRAC connection. The S5248F-ON ports used for iDRAC connections must be in a port-group set to 10GbE with the mode eth 10g-4x command. See Appendix B for more information on port-groups. 11 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 12
ConnectX-4 Lx The Mellanox ConnectX-4 Lx is a dual port 25GbE network adapter that supports RoCEv2. If Mellanox ConnectX-4 adapters are used, DCB is not required. However, Dell EMC recommends using DCB if NVMe drives are in use. 12 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 13
named ProdSwitch in this example, configured for Switch Embedded Teaming (SET). SET allows between one and eight physical Ethernet network adapters to be grouped into one or more software-based .16.14.4 172.16.11.5 172.16.11.250 13 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 14
Menu page, select Device Settings. Device Settings menu item 5. On the Device Settings page, click the first network adapter port in the list to launch the Main Configuration Page for the port. First NIC port in the device list 14 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 15
, select BIOS Setup. 3. Reboot the server. 4. On the System Setup Main Menu, select Device Settings. 5. Click on the first QLogic QL41262 port to launch the Main Configuration Page for the port. QL41262 adapter Port 1 menu item 15 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 16
Virtualization Mode is set to None. Virtualization Mode set to None 8. Click the Back button to return to the Main Configuration Page. 9. On the Main Configuration Page, click NIC Configuration. NIC Configuration menu item 16 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 17
f. Virtual LAN ID - 1 QLogic NIC port settings configured 11. Click the Back button to return to the Main Configuration Page. 12. On the Main Configuration Page, click Data Center Bridging (DCB) Settings. DCB Settings menu item 17 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 18
for S2D deployments. ETS and PFC settings are configured manually on the switch and the network adapter later in this guide. 14. Click Back > Finish adapter port. 15. When complete, exit System Setup and reboot the system. 18 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 19
Settings. 5. Click on the first Mellanox ConnectX-4 adapter port to launch the Main Configuration Page for the port. Mellanox adapter Port 1 highlighted 6. On the Main Configuration Page, click NIC Configuration. NIC Configuration highlighted 19 Dell EMC Solutions for Microsoft Azure Stack - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 20
None b. Virtual LAN Mode - Disabled NIC Configuration 8. Click the Back button to return to the Main Configuration Page. 9. On the Main Configuration Page, click Device Level Configuration. Device Level Configuration highlighted 20 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 21
> Yes (to save the changes if applicable) > OK (to acknowledge the change success message if applicable). Repeat steps 5-11 above for the 2nd Mellanox adapter port. 12. When complete, exit System Setup and reboot the system. 21 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 22
EMC are available for download on Dell Digital Locker. Installation instructions are provided in the OS10 Enterprise Edition User Guide Release 10.4.2.0. OS10# show license status System Information Vendor Name : Dell EMC Product Name : S5248F-ON Hardware Version: A01 Platform Name - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 23
enabled, and the OOB management interface configured to get its IP address via DHCP. The default username and password are both admin. Dell EMC recommends changing the admin password to a complex password during the first login. 23 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 24
ON leaf switches. The switches start at their factory default settings per Section 6.3. The commands in the sections that follow should be entered in the order shown. Note: S5248F-Leaf1A and S5248F-Leaf1B switch running-configuration files, with and without DCB, are provided as text file attachments - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 25
Set the mode to 10GbE. Change port groups from 25GbE to 10GbE S5248F-Leaf1A S5248F-Leaf1B port-group 1/1/6 mode eth 10g-4x port-group 1/1/6 mode eth 10g-4x port-group 1/1/8 mode eth 10g-4x port-group 1/1/8 mode eth 10g-4x 25 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 26
is the OS10EE default value for VRRP priority. When set to 100, as is done on Leaf1B below, the VRRP priority will not appear in the output of the show running-configuration command. The vlan1614 description Storage_2 no shutdown 26 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 27
commands in the DCB configuration section of this guide, Section 7.7, will turn flow control off if it has been enabled. 6. Configure ports directly connected to nodes, servers, or other endpoints as STP edge ports. Storage interface configuration S5248F-Leaf1A interface ethernet1/1/1 description - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 28
ethernet1/1/31:1 description Mgmt_1-1 no shutdown switchport access vlan 1611 spanning-tree port type edge interface ethernet1/1/31:1 description Mgmt_1-2 no shutdown switchport access vlan 1611 spanning-tree port type edge 28 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 29
7.6 Configure VLT The QSFP28-DD ports on the S5248F-ON are used for the VLTi between the two leaf switches as shown in Figure 5. The two physical QSFP28-DD ports provide four 100GbE interfaces, 1/1/49-1/1/52. Configure the VLTi interfaces as follows: 1. Provide an interface description. 2. Remove - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 30
. ETS and PFC settings are configured manually on both the switch and the NIC. 3. Enter system QoS mode. 4. Configure the system to trust incoming dot1p values. 5. Exit system QoS mode. Global DCB configuration S5248F-Leaf1A configure terminal S5248F-Leaf1B configure terminal no dcbx enable - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 31
class-map type network-qos HB match qos-group 5 policy-map type network-qos pfc-policy class SMB pause pfc-cos 3 class HB pause pfc-cos 5 policy-map type network-qos pfc-policy class SMB pause pfc-cos 3 class HB pause pfc-cos 5 31 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 32
receive off flowcontrol transmit off service-policy input type network-qos pfc-policy priority-flow-control mode on service-policy output type queuing ets-policy ets mode on qos-map traffic-class queue-map end write memory 32 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 33
VLTi. VLAN ID 4094 is reserved as an internal control VLAN for the VLT domain, and it is not user configurable. S5248F-Leaf1A# show vlan Codes: * - Default VLAN, M - Management VLAN, R - Remote Port Mirroring VLANs, @ - Attached to Virtual Network Q: A - Access (Untagged), T - Tagged NUM Status - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 34
value, shown in the Priority column, is the VRRP master. S5248F-Leaf1A# show vrrp brief Interface Group Priority Prempt State Version Master addr(s) Virtual addr vlan1611 IPv4 11 150 true master 2 172.16.11.252 172.16.11.254 34 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 35
HeartBeat status must be Up. S5248F-Leaf1A# show vlt 127 backup-link VLT Backup Link Destination : 100.67.168.31 Peer Heartbeat status : Up Heartbeat interval : 30 Heartbeat timeout : 90 Destination VRF : default 35 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 36
configuration issues between VLT peers. Mismatch examples include incompatible VLT configuration settings and VLAN differences. Any mismatches reported should be resolved before proceeding. S5248F-Leaf1A# show vlt 127 mismatch VLT 36 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 37
validated for this guide. • The latest Windows updates are installed on each system. • All device firmware and drivers on the Ready Nodes are up-to-date and are at the same or later versions as those listed in the Support Matrix for Dell EMC Solutions for Microsoft Azure Stack HCI. Note: The - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 38
only configured on the QLogic or Mellanox adapters for this deployment. Dell EMC set to Disabled as shown in Figure 23. DCB disabled on X710 network adapter port 4. Repeat steps 2-3 for the second Intel Ethernet 10G X710 port. 38 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 39
examples are listed in Chapter 10. Note: On WS2016, the default SET load balancing method is Dynamic. On WS2019, the default SET load balancing method is Hyper-V Port. Default load balancing methods are used in the examples in this guide. 1. In PowerShell, run the New-VMSwitch cmdlet on each Ready - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 40
addresses shown are specific to Ready Node 1. PS> New-NetIPAddress -InterfaceAlias 'SLOT 2 PORT 1' -IPAddress 172.16.13.1 PrefixLength 24 PS> New-NetIPAddress -InterfaceAlias 'SLOT 2 PORT 2' -IPAddress 172.16.14.1 PrefixLength 24 40 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 41
depending on the Windows Server version installed as shown below. To set the RDMA mode to iWARP on ports with the command: PS> Set-NetAdapterAdvancedProperty -Name 'SLOT 2*' -RegistryKeyword '*JumboPacket' -RegistryValue '9014' 41 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 42
Spaces Direct cluster. Note: Connecting to AD services using the host management network may require routing Add-Computer -DomainName dell.lab -Credential $credential -Restart 9.7 Note: Substitute dell.lab in the Ready Nodes in this deployment. The Dell BOSS drive displays False in the CanPool - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 43
Set-Disk -isreadonly:$true $_ | Set-Disk -isoffline:$true } Get-Disk | Where Number -Ne $Null | Where IsBoot -Ne $True | Where IsSystem -Ne $True | Where PartitionStyle -Eq RAW | Group storage-03 storage-03 storage-04 storage-04 43 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 44
02, storage-03, storage-04 - Include 'Storage Spaces Direct', 'Inventory', 'Network', 'System Configuration' Note: Replace the node names in the command above with the names used in your environment. .01.29 At 16.00.10.htm Name 44 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 45
/2014/03/31/configuring-a-fileshare-witness-on-a-scale-out-file-server. For information about configuring a cloud-based witness, see https://docs.microsoft.com/en-us/windows-server/failover-clustering/deploy-cloud-witness. 45 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 46
configuration steps as they are executed on the screen. The above command will fail if run from the management system because the Cluster Service [L] No to All [S] Suspend [?] Help (default is "Y"): 2. Answer Y to proceed. When Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 47
'Host in charge' PS> Set-NetAdapterAdvancedProperty -Name 'SLOT 2 PORT 2' -DisplayName 'Dcbxmode' -DisplayValue 'Host in charge' DCB configuration on the server is verified with the Get- cmdlets shown in Section 10.11. 47 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 48
to validate the configuration. Note: Some SET load balancing method used determines the vEthernet (Management) link speed shown in the output above. On WS2019, the default SET load balancing method is Hyper-V Port. With Hyper-V Port Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 49
Port 1 172.16.13.1 SLOT 2 Port 2 172.16.14.1 Loopback Pseudo-Interface 1 127.0.0.1 10.4 Get-NetRoute The Get-NetRoute cmdlet is used to verify the default gateway configured on the Ready Node. The default gateway is configured Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 50
-V Virtual Ethernet SLOT 2 Port 1 Mellanox ConnectX-4 Lx E SLOT 2 Port 2 Mellanox ConnectX-4 Lx QLogic adapters are set to iWARP. The command syntax varies depending on the version of Windows Server installed. iWARP is {1514} 50 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 51
Journal 894.25 GB ATA MZ7KM960H SSD False OK Healthy Journal 894.25 GB ATA ST4000NM0 HDD False OK Healthy Auto-Select 3.64 TB 51 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 52
: All Precedence : 127 Template : Cluster JobObject : PriorityValue : 5 Name : SMB Owner : Group Policy (Machine) NetworkProfile : All Precedence : 127 JobObject : NetDirectPort : 445 PriorityValue : 3 52 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 53
parameters. Verify the OperationalTrafficClasses bandwidth and priorities match those configured on the switch, shown in Table 11, and OperationalFlowControl : Protocol Port/Type Priority Default 0 NetDirect 445 3 53 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 54
is configured to Name ---[Default] SMB Port 1 SLOT 2 Port 2 DisplayName ----------DcbxMode DcbxMode DisplayValue -----------Host in Charge Host in Charge RegistryKeyword RegistryValue DcbxMode {0} DcbxMode {0} 54 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 55
help verify DCB is configured correctly. The commands and output shown are for S5248F-Leaf1A. The output of its peer, S5248F-Leaf1B, is similar. 0 0 0 1 0 0 2 0 0 3 287 20 4 0 0 5 287 0 6 0 0 7 0 0 55 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 56
: For the current list of supported firmware and driver versions, see the Support Matrix for Dell EMC Solutions for Microsoft Azure Stack HCI. A cluster of four PowerEdge R740xd S2D Ready Nodes was used to validate the examples in this guide. The nodes were each configured as shown in Table 15 for - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 57
system used in this guide is a PowerEdge R640 configured as shown in the table below. PowerEdge R640 management system components with WS2019 Qty Item Firmware 1 Intel Xeon Gold .26.22 Driver 6.604.6.0 7.13.57.103 - 57 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 58
A.4 A.5 Dell EMC Networking Optics and Cables The optics and cables in the table below were used to validate the examples in this guide. Optics and cables Qty Item 16 SFP28-25G-SR or SFP28-25G-SR-NOF optical transceiver 20 10G SFP+ SR optical transceiver 18 LC/LC OM3 MMF patch cable 2 - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 59
number. In this example, changing interfaces eth1/1/21-1/1/24 and 1/1/31 to 10GbE also changes the interface names to eth1/1/21:1- 1/1/24:1 and 1/1/31:1. Port-group configuration options for the S5248F-ON are shown in Table 19. 59 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 60
S5248F-ON port-group configuration options Port group number Native physical interface Native speed Other supported speeds Non-native logical interface Eth 1/1/x:n Eth 1/1/x:n Eth 1/1/x:n Eth 1/1/x:n Eth 1/1/x:n Eth 1/1/x:n 60 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 61
User Guide Release 10.4.2.0 Manuals and documentation for Dell EMC Networking S3048-ON Manuals and documentation for Dell EMC Networking S5248F-ON Dell EMC Solutions for Microsoft Azure Stack HCI page Dell EMC Solutions for Microsoft Azure Stack HCI Deployment Guide Support Matrix for Dell EMC - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 62
for turnkey solutions and automation based on validated deployment guides. FDC allows design customization and flexibility to go beyond validated deployment guides. For additional information, visit the Dell EMC Fabric Design Center. 62 Dell EMC Solutions for Microsoft Azure Stack HCI Networking - Dell S3048-ON | EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 63
.dell.com/support Telephone: USA: 1-800-945-3355 Feedback for this document We encourage readers to provide feedback on the quality and usefulness of this publication by sending an email to [email protected]. 63 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide
Dell EMC Configuration and Deployment Guide
Dell EMC Solutions for Microsoft Azure Stack HCI
Networking Guide
Abstract
This guide provides Microsoft Azure Stack HCI networking deployment
examples using Dell EMC Storage Spaces Direct Ready Nodes and Dell
EMC Networking switches.
May 2019