Dell S3048-ON EMC Networking Virtualization Overlay with BGP EVPN
Dell S3048-ON Manual
View all Dell S3048-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell S3048-ON manual content summary:
- Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 1
EVPN Deploying a BGP EPVN leaf-spine topology with VXLAN anycast gateways Abstract This guide covers the deployment of a physical Layer 3 leaf-spine underlay network and Layer 2 virtual network overlays with anycast gateways using VXLAN-based BGP EVPN. May 2019 Dell EMC Configuration and Deployment - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 2
of any software described in this publication requires an applicable software license. © 2019 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 3
(S4148U-ON only 20 6 Configure leaf switches ...21 6.1 Initial configuration settings ...21 6.2 VLT configuration...22 6.3 Virtual network configuration ...22 6.4 VLAN configuration...24 6.5 Downstream interface configuration ...25 6.6 Upstream interface configuration...26 3 Dell EMC Networking - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 4
l2vpn evpn ...43 8.4.5 show evpn mac-ip...45 9 Spine switch validation ...46 9.1 General commands ...46 9.1.1 show interface status...46 9.1.2 show lldp neighbors...46 9.2 Routing validation commands ...47 9.2.1 show bfd neighbors ...47 4 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 5
network interface configuration 63 A.4 Upstream interfaces ...63 A.5 Static routes to VNIs...63 B Validated components...64 B.1 Dell EMC PowerSwitches...64 B.2 PowerEdge R740xd Servers ...64 B.3 VMware software ...64 C Technical resources ...65 C.1 Dell EMC product manuals and technical guides 65 - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 6
maintaining a high standard of quality, consistency, and support. This guide provides a step-by-step deployment example of Border Gateway Protocol (BGP) Ethernet Virtual Private Network (EVPN) for Virtual Extensible LAN (VXLAN) using Dell EMC PowerSwitches and PowerEdge servers. BGP EVPN for VXLAN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 7
requiring connectivity for 25GbE and 10GbE compute and storage. This guide uses two S5248F-ONs as leaf switches. 2.2 Dell EMC PowerSwitch S5248F-ON Dell EMC PowerSwitch S4148U-ON The Dell EMC PowerSwitch S4148U-ON is a 1-RU, multilayer switch with twenty-four 10GbE ports, two 40GbE ports, four 10 - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 8
ports, or up to 128 10/25/40/50GbE ports using supported breakout cables. This guide uses two Z9264F-ONs as spine switches. 2.4 Dell EMC PowerSwitch Z9264F-ON Dell EMC PowerSwitch S3048-ON The Dell EMC PowerSwitch S3048-ON is a 1-RU switch with forty-eight 1GbE BASE-T ports and four 10GbE SFP - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 9
VPNs like Virtual Private LAN Service (VPLS). Some of its key features are: • Support for multi-tenancy • Layer VNI B Anycast gateway VNI C Indirect gateway This deployment guide demonstrates the following: VTE P Leaf VLT Leaf Border Leafs Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 10
a result, all switches in the underlay (physical) network must be configured to support an MTU of switch interfaces are set to their maximum supported MTU size of 9216 bytes. VTEPs handle VXLAN encapsulation and de-encapsulation. In this implementation, the leaf switches are the VTEPs. 10 Dell EMC - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 11
leaf switches. As of OS10EE version 10.4.3.1, Dell EMC PowerSwitches support asymmetric IRB. This means that overlay routing, also known as RIOT, occurs on ingress leaf switches. gateway to access the Internet by configuring static routes. 11 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 12
as spines and two leaf switches per rack, this topology will scale to 32 racks. For additional leaf-spine network information, refer to Dell EMC PowerSwitch Layer 3 Leaf-Spine Deployment and Best Practices with OS10. There are some BGP configuration differences in this guide to enable the BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 13
ASNs) and router IDs used for the leaf and spine switches in this guide. Spine switches share a common ASN and each pair of leaf switches shares a common ASN. ASNs should follow a logical pattern 2 JK L Leaf 3a VOLTi Leaf 3b Rack n 13 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 14
192.168.3.2/31 192.168.3.4/31 Note: As with all examples in this guide, any valid IP address scheme can be used. The example point-topoint addresses above use a 31-bit mask to save address space. This is optional and covered in RFC 3021. 14 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 15
port). This requires two QSFP28-DD DAC cables. However, QSFP28-DD ports are not available on S4148U-ONs also used as leaf switches in this guide. For this deployment example, all six leafs use two QSFP28 ports per switch for the VLTi. 15 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 16
R740xd-1 VM VM R740xd-2 VM VTEP 10.222.222.2 S4148U-2a VLTi S4148U-2b 172.16.14.253 172.16.15.253 VLT VM 1616. All VNIs are configured all on six leaf switches. However, only VNIs 1614 and 1615 are configured with anycast gateways. Because Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 17
, and other devices. It is also used to carry heartbeat messages sent between leaf switches configured as VLT peers. Dell EMC recommends using at least one S3048-ON switch per 42-RU rack for OOB management network connections. Each S3048-ON has forty-eight 1GbE Base-T ports for connections to - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 18
an OOB management switch with its factory default settings, or it may be configured as needed for your environment. By default, all ports are in switchport mode, in VLAN 1, administratively up, and rapid per-VLAN spanning tree plus (RPVST+) is enabled. At a minimum, Dell EMC recommends changing the - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 19
instructions are provided in the OS10 Enterprise Edition User Guide Release 10.4.3.0 OS10# show license status System Information Vendor Name : Dell EMC Product Name : S5248F-ON Hardware Version : A01 Platform Name : x86_64-dellemc_s5248f_c3538-r0 PPID : CN046MRJCES0089K0004 Service - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 20
are both admin. Dell EMC recommends changing the admin password to a complex password during the first login. Configure switch port profile (S4148U-ON only) Note: This section is specific to the S4148U-ON switches used as examples in this guide. Port profiles are currently supported on the S4148-ON - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 21
S4148U-ON switches are set to switch-port-profile 3 as described in Section 5.4. The leaf switch configuration tree protocol type supported by the switch is acceptable. This example uses RSTP. The first leaf in the pair is configured as the Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 22
delay-restore 120 discovery-interface ethernet 1/1/55 discovery-interface ethernet 1/1/56 vlt-mac 00:00:01:02:03:01 Note: The remaining leaf switches are configured in the same manner. Dell EMC recommends using at least two high-bandwidth ports for the VLTi. Port numbers used will vary depending on - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 23
this example, VNI 1616 uses an indirect gateway and does not use a virtual router address. 7. Configure the anycast gateway MAC address using the ip virtual-router mac-address command. The same MAC address is ip address 172.16.15.242/24 23 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 24
-network 1616 no shutdown interface vlan4000 ip address 192.168.3.0/31 interface vlan4000 ip address 192.168.3.1/31 Note: The remaining leaf switches are configured in the same manner. VRF tenant1 is created on all six leaf switches. 24 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 25
active Note: Leaf switches 2a and 2b are configured in the same manner, with VLT port channels going to Server 3 and Server 4. Leaf switches 3a and 3b are connected to the switch acting as an external gateway/firewall via a single VLT port channel. 25 Dell EMC Networking Virtualization Overlay - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 26
.168.2.3/31 mtu 9216 no shutdown Note: The remaining leaf switches are configured in the same manner. S4148U-ON leaf switches use different ports, ethernet 1/1/25-1/1/26, for the 100GbE . This range includes all VTEP IP addresses. 26 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 27
downstream ethernet1/1/54 enable Note: The remaining leaf switches are configured in the same manner. Upstream ports are the 3b. S4148U-ON leaf switches use different downstream ports, ethernet 1/1/251/1/26, for the 100GbE connections to the spines. 27 Dell EMC Networking Virtualization - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 28
eBGP maximum paths to 2 since there are two paths (one through each spine switch). 6. Enable graceful restart. 7. Configure the neighbors that share routes to the VTEPs: a. Specify the neighbor by its as 65101 address-family ipv4 unicast 28 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 29
neighbor 192.168.3.1 remote-as 65201 no shutdown neighbor 192.168.3.0 remote-as 65201 no shutdown Note: The remaining leaf switches are configured in the same manner. AS numbering and IP addressing is done per Figure 9 and Table 1. 29 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 30
0.0.0.0/0 172.16.16.253 Leaf1b ip route vrf tenant1 0.0.0.0/0 172.16.16.253 end write memory end write memory Note: The remaining leaf switches are configured with identical settings to those shown above in this deployment example. 30 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 31
protocol as a precaution against loops. Any spanning tree protocol type supported by the switch is acceptable. This example uses RSTP. 5. Enable BFD. Initial configuration settings Spine1 configure terminal Spine2 configure terminal hostname Spine1 interface mgmt 1/1/1 no ip address ip address - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 32
2. Configure a loopback interface to be used as the BGP router ID and IP address for BGP EVPN peering per Figure 9. ID" ip address 10.2.1.1/32 no shutdown interface loopback 1 description "Router ID" ip address 10.2.1.2/32 no shutdown 32 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 33
maximum paths to 2 since there are two paths (one through each spine switch). 6. Enable graceful restart. 7. Configure the neighbors that share routes to the VTEPs: a. Specify the neighbor by family and activate the EVPN address family. 33 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 34
with the end and write memory commands. BGP configuration Spine1 router bgp 65101 bfd all-neighbors interval 200 min_rx 200 multiplier 3 role 168.2.9 advertisement-interval 5 bfd fall-over remote-as 65203 address-family ipv4 unicast 34 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 35
ipv4 unicast no activate address-family l2vpn evpn activate neighbor 10.2.2.4 ebgp-multihop 2 remote-as 65202 send-community extended update-source loopback1 no shutdown 35 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 36
-as 65203 send-community extended update-source loopback1 no shutdown address-family ipv4 unicast no activate address-family l2vpn evpn activate end write memory 36 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 37
configuration. This section provides a list of common commands and their output for this topology. Note: The commands and output shown below are for Leaf1a. The output for the other leaf switches Active T Po1000 4094 Active T Po1000 37 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 38
neighbors command is useful for identifying connected switches by port. The items listed as UFD group. The status should be Enabled,up. Since UFD is configured in reverse, the VLT port channels connected to the servers, Po Eth 1/1/54(Up) 38 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 39
include incompatible VLT configuration settings and VLAN differences. Any mismatches reported should be resolved before proceeding. S5248F-Leaf1A# show vlt 127 mismatch VLT-MAC mismatch: No mismatch Peer-routing mismatch: No mismatch VLAN mismatch: 39 Dell EMC Networking Virtualization Overlay - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 40
status will be down until LAGs are configured on the connected hosts. This is covered in Section 10.9 of this guide. The * in the command output -Channel Status Configured ports Active ports 1 port-channel101 down 1 1 * 2 port-channel101 down 1 1 40 Dell EMC Networking Virtualization - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 41
0/0 04:38:08 C 192.168.2.0/31 via 192.168.2.1 ethernet1/1/54 0/0 04:38:08 C 192.168.3.0/31 via 192.168.3.0 vlan4000 0/0 02:39:37 41 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 42
, VNI 1615 Route-Distinguisher : 1:10.222.222.1:1615 Route-Targets : 0:1615:1615 both Inclusive Multicast : 10.222.222.2, 10.222.222.3 IRB : Enabled(tenant1) 42 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 43
0 65101 65203 ? *> Route distinguisher: 10.222.222.1:1614 VNI:1614 [2]:[0]:[48]:[e4:f0:04:81:40:98]:[0]:[0.0.0.0]/280 10.222.222.3 0 100 0 65101 65203 ? 43 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 44
.222.1 10.222.222.1 10.222.222.1 10.222.222.3 10.222.222.3 10.222.222.3 10.222.222.3 10.222.222.1 (output truncated) 44 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 45
.222.2 10.222.222.3 10.222.222.3 virtual-network1616 10.222.222.3 10.222.222.2 10.222.222.2 10.222.222.3 10.222.222.3 45 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 46
9 Spine switch validation After connected devices are configured, many commands are available to validate the network configuration. This section provides a list of the most common commands and Leaf3b ethernet1/1/25 e4:f0:04:81:3f:cc 46 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 47
.222.2/32 via 192.168.1.5 20/0 00:52:16 via 192.168.1.7 B EX 10.222.222.3/32 via 192.168.1.9 20/0 00:52:17 47 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 48
:05:54 10.2.2.5 65203 89 123 01:05:53 10.2.2.6 65203 90 119 01:05:54 State/Pfx 24 24 16 16 16 16 48 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 49
configured in the preceding sections if ESXi and vCenter are used in the environment. 10.1 VMware ESXi download and installation Install VMware ESXi 6.7 Update 1 or later on each PowerEdge server. Dell EMC recommends using the latest Dell EMC customized ESXi .iso image available on support.dell - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 50
10.4 Create VMs and install guest operating systems To create VMs and install supported guest operating systems on hosts running VMware ESXi, see vSphere 6.7 Virtual Machine . It is not assigned to a virtual network in this example. 50 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 51
switches are configured in the vSphere Web Client, and the configuration is populated across all hosts associated with the switch. A VDS is used for connectivity to the production network in this guide. Distributed Switches . 3. Click OK. 51 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 52
Distributed port groups created 10.8 Create LACP LAGs Since VLT port channels are configured on the leaf switches, LACP LAGs are configured on the VDS. To enable LACP on Mgmt-VDS: 1. In the vSphere default values as shown in Figure 17. 52 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 53
LAG configuration d. Click OK to close the dialog box. This creates lag1 on the VDS. The refresh icon ( ) at the top of the screen may need to be clicked for the lag to appear in the table as shown in Figure 18. Lag1 created on Mgmt-VDS 53 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 54
the leaf switches. This can be determined by going to Home > Hosts and Clusters and selecting the host in the Navigator pane. In the center pane, select Configure > page, Overall impact status should indicate . g. Click Next > Finish. 54 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 55
in Figure 19. LAGs configured on Mgmt-VDS This configuration brings up the VLT port channels on the leaf switches. This is confirmed by Port-Channel Status Configured ports Active ports 1 port-channel101 up 1 1 * 2 port-channel101 up 1 1 55 Dell EMC Networking Virtualization - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 56
network adapter on the VM is now connected to VLAN/VNI 1614. Repeat steps 2-7 for remaining VMs, placing them on the appropriate VLAN/VNI. 56 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 57
leaf switches. Virtual machine locations and IP addressing Virtual machine name VLAN/VNI IP Address VM-1614-x 1614 172.16.14.x/24 VM-1615-x 1615 172.16.15.x/24 VM-1616-x 1616 172.16.16.x/24 Gateway 172.16.14.253 172.16.15.253 172.16.16.253 57 Dell EMC Networking - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 58
11 Validate connectivity The switches in this guide were configured to allow all -1614-1 R740xd-1 VM-1616-1 R740xd-2 VTEP 10.222.222.2 S4148U-2a VLTi S4148U-2b 172.16.14.253 172.16.15.253 VLT VM-1614-3 R740xd-3 VM is shown in Figure 23. 58 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 59
Rack 1 and Rack 2 respectively. The second red box shows the packet sent from VM-1614-1 is encapsulated with VXLAN on VNI 1615. This is 59 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 60
pair in Rack 1. Its default gateway is the indirect gateway, 172.16.16.253. The Gateway/Firewall switch is connected to the third leaf pair in Rack 3 as shown in Figure 22. A packet capture a ping request selected is shown in Figure 26. 60 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 61
and packets travel to their destination on the destination VNI with asymmetric IRB. The third red box shows the source and destination IP addresses. 61 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 62
.254 spanning-tree mode rstp Indirect gateway configuration 1. Configure VLAN 1. 2. Specify the IP address used as the indirect gateway. Gateway configuration Gateway/firewall switch interface vlan1 no shutdown ip address 172.16.16.253/24 62 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 63
network. Loopback interface configuration Gateway/firewall switch interface loopback0 description testlo0 switch ip route 172.16.14.0/24 172.16.16.245 ip route 172.16.14.0/24 172.16.16.246 ip route 172.16.15.0/24 172.16.16.245 ip route 172.16.15.0/24 172.16.16.246 end write memory 63 Dell EMC - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 64
used to configure and validate the examples in this guide. Dell EMC PowerSwitches Switches and OS versions Qty Item 2 Dell EMC PowerSwitch S5248F-ON leaf switch 4 Dell EMC PowerSwitch S4148U-ON leaf switch 2 Dell EMC PowerSwitch Z9264-ON spine switch 1 Dell EMC PowerSwitch S3048-ON - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 65
S3048-ON Manuals and documentation for Dell EMC PowerSwitch S4148U-ON Manuals and documentation for Dell EMC PowerSwitch S5248F-ON Manuals and documentation for Dell EMC PowerSwitch Z9264F-ON Manuals and documentation for Dell EMC PowerEdge R740xd VMware product manuals and technical guides VMware - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 66
for turnkey solutions and automation based on validated deployment guides. FDC allows design customization and flexibility to go beyond validated deployment guides. For additional information, visit the Dell EMC Fabric Design Center. 66 Dell EMC Networking Virtualization Overlay with BGP EVPN - Dell S3048-ON | EMC Networking Virtualization Overlay with BGP EVPN - Page 67
Support Support Contact Information Web: http://www.dell.com/support Telephone: USA: 1-800-945-3355 Feedback for this document We encourage readers to provide feedback on the quality and usefulness of this publication by sending an email to [email protected]. 67 Dell EMC
Dell EMC Configuration and Deployment Guide
Dell EMC Networking Virtualization Overlay with
BGP EVPN
Deploying a BGP EPVN leaf-spine topology with VXLAN anycast
gateways
Abstract
This guide covers the deployment of a physical Layer 3 leaf-spine
underlay network and Layer 2 virtual network overlays with anycast
gateways using VXLAN-based BGP EVPN.
May 2019