Dell S3048-ON EMC PowerSwitch Installation Guide March 2022

Dell S3048-ON Manual

Dell S3048-ON manual content summary:

  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 1
    Dell EMC PowerSwitch S3048-ON Installation Guide March 2022 March 2022 Rev. A10
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 2
    data and tells you how to avoid the problem. NOTE: A WARNING indicates a potential for property damage, personal injury, or death. © 2014 - 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 3
    the S3048-ON 14 Unpack ...14 Unpacking steps...14 Rack or cabinet hardware installation...15 ReadyRails system installation...15 Switch installation...18 1U front-rack installation...18 Ground cable...20 Optics installation...20 Optics removal...20 Switch power-up...20 Chapter 6: Power supplies
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 4
    installing the switch...26 Chapter 8: Management ports...27 RS-232 console port access...27 USB storage mount...28 Before you install an OS...28 ONIE service discovery...29 Chapter Electromagnetic compatibility ...35 Product recycling and disposal...35 Chapter 10: Dell EMC support...37 4 Contents
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 5
    the S3048-ON switch, see the following documentation: ● Dell Networking S3048-Open Networking (ON) Getting Started Guide ● Dell Networking S3048-Open Networking (ON) Release Notes ● Dell Open Networking Troubleshooting Guide NOTE: For the most recent documentation, see the Dell EMC support: www.dell
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 6
    40 Gbps switching fabric in the core. Figure 2. S3048-ON I/O-side view 1. Forty-eight 10/100/1000BAse-T RJ-45 ports 2. Four SFP+ ports 3. Serial console port 4. USB 2.0 port 5. Management port Figure 3. S3048-ON PSU-side view 1. Three fan modules 2. Two power supply units 6 The S3048-ON switch
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 7
    time clock (RTC) support ● Hot-plug redundant power supply ● Power management monitoring ● Removable fans ● Standard 1U chassis Physical dimensions The S3048-ON has the following physical dimensions: ● 434 x 320 x 44 mm (W x D x H) ● 17.09 x 12.60 x 1.73 inches (W x D x H) Switch status You can view
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 8
    ● Solid Green-Normal ● Solid yellow-POST is in process ● Blinking yellow-Power supply failed ● Off-Switch is in Stacking Slave mode ● Solid green-System is in Stacking Master or Standalone mode ● Solid green-Fan powered and running at the expected RPM ● Solid yellow-Fan failed including incompatible
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 9
    rack or cabinet Switch configurations You can order the S3048-ON switch in several different configurations. You can order the following supported hardware components: ● S3048-ON AC Normal Airflow: Forty-eight 10/100/1000Base-T RJ-45 ports with four SFP+ 10 G ports, one AC power supply, and three
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 10
    Switch ground • Fans and airflow • Power • Storing components Site selection Install Dell EMC equipment in restricted access areas. A restricted access area is one in which service your S3048-ON switch meets the following safety requirements: ● Near an adequate power source. Connect the switch to
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 11
    point the power service in your area uses. The ground path must be permanent. Switch ground Dell EMC recommends you ground your switch. Use the S3048-ON in a common bond network (CBN). Connect the grounding cables as described in Install the S3048-ON. Fans and airflow The S3048-ON fans support two
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 12
    NOTE: ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S3048-ON and its accessories. After you remove the original packaging, place the S3048-ON and its components on an anti-static surface. 12 Site preparations
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 13
    (NEBS) compliant, you must follow the instructions detailed in this section. To be NEBS compliant, orient your switch in the rack so that the air inlet interfaces metallically to OSP wiring. WARNING: If you install and connect the S3048-ON to a commercial AC power source, you must connect the switch
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 14
    Rack or cabinet hardware installation 3. Switch installation 4. Optics installation 5. Power up the switch NOTE: ESD damage can occur if -specific power cord ● Dell Networking S3048-Open Networking (ON) Getting Started Guide ● Safety and Regulatory Information ● Warranty and Support Information
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 15
    , for example: use of power strips. ● Do not mount the equipment with the rear panel facing in the downward position. ReadyRails system installation The ReadyRails rack mounting system is provided to easily configure your rack for installation of your S3048-ON switch. You can install the ReadyRails
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 16
    item 1. To remove the two screws from each front flange ear on the switch side of the rail and remove each casting, use a Torx screwdriver. Retain 6. Two-post flush-mount configuration 2. Attach one rail to the front post flange with two user-supplied screws, item 2. 16 Install the S3048-ON
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 17
    the post. Secure it to the post flange with two user-supplied screws, to item 2. 3. Repeat this procedure for the second rail. Four-post threaded installation 1. For this configuration, remove the flange ear castings from each end of the ReadyRails assemblies. To remove the two screws from each
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 18
    and rear flanges to the post flanges with two user-supplied screws at each end, item 2. Switch installation You can mount the switch in the 1U front-rack or 1U flush or center two-post configurations. The following is an example of a front-rack configuration: For the 1U flush or center two-post
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 19
    in until it is flush with front of rack. About three inches before you fully insert your switch, the rail locking feature engages to keep the switch from inadvertently sliding out of the rack and falling. Figure 10. Front rack installation NOTE: Do not the use the mounted ReadyRails as a shelf
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 20
    to ensure it is seated properly. Do not jerk or tug repeatedly on the tab. Switch power-up Supply power to the S3048-ON after it is mounted in a rack or cabinet. Dell EMC recommends reinspecting your switch before powering up. Verify the following: ● The equipment is properly secured to the rack and
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 21
    for powering up an AC power supply. You must order all other power cables separately. NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S3048-ON switch and its components. Power up sequence When the switch powers up
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 22
    with one AC power supply. Dell EMC recommends purchasing a second power supply. The S3048-ON supports AC power supplies with two air-flow directions-from the I/O side to the PSU side and from the PSU side to the I/O side. Two PSUs are required for full redundancy, but the switch can operate with
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 23
    , Dell EMC recommends installing the power supply in the first slot (PSU1) and installing a blank plate in the second slot (PSU2). 1. Remove the PSU slot cover from the S3048-ON using a small #1 Phillips screwdriver. 2. Remove the PSU from the electro-static bag. 3. Insert the PSU into the switch
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 24
    the S3048-ON chassis. NOTE: If a PSU fails, you must replace the entire unit. There are no field serviceable components in the PSU. NOTE: If you use a single PSU, install a blank plate in the other PSU slot. If you are only using one power supply, Dell EMC recommends installing the power supply in
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 25
    each slot either as part of the PSU or as an independent fan module, the switch shuts down in one minute. In addition to the power supply modules, you can order and install fan modules separately. The S3048-ON supports two airflow direction options. Do not mix airflow types in a chassis; you can use
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 26
    2 and 3 within one minute or the switch powers down. 1. Slide the fan module out of the bay. 2. Slide the replacement module into the bay. After installing the switch After you have securely installed and powered on the S3048-ON, to configure your switch, see your ONIE-compatible operating system
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 27
    S3048-ON switch provides several ports for management and storage. Topics: • RS-232 console port access • Before you install an OS • ONIE service discovery RS-232 console port access The RS-232 console port is on the I/O-side of the S3048 Keep the default terminal settings on the console as follows:
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 28
    supports 512 = 8225280 bytes Device Boot /dev/sda1 Start 1 End 1925 Blocks Id System 15458303+ ee EFI GPT For USB defaults,rw,errors=remount-ro 0 1 /dev/sdb /mnt/usb vfat defaults 0 1 ONIE:/ # mount -a Before you install an OS After powering on the S3048-ON switch, it goes through a power
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 29
    manually ONIE: Uninstall OS Restore to factory defaults erases any installed OS ONIE: Update ONIE For downloading and updating ONIE from a URL ONIE: Embed ONIE For downloading and updating ONIE from a URL and erases any installed OS ONIE: Diag ONIE Run Diagnostic package for S3048-ON Dell
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 30
    RX bytes:1152 (1.1 KiB) TX bytes:6864 (6.7 KiB) Interrupt:21 Memory:ff300000-ff320000 To assign an IP address to the management interface, eth0, and verify network connectivity, use the ifconfig eth0 command, as shown. ONIE:/ # ifconfig eth0 10.11.53.33/16 Verify the network
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 31
    Specifications This chapter lists the S3048-ON specifications. CAUTION: Operate battery. Dispose of the batteries according to the manufacturer's instructions. NOTE: For RoHS information, see Restricted Material Compliance. Width Depth Chassis Weight with Factory-Installed Components Rack Clearance
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 32
    power requirements Parameter Power Supply Maximum Current Draw Per System PSU Maximum Power Capability PSU Maximum Power Capability, North America Only Typical Power 1,154,397 hours IEEE Standards The S3048-ON complies with the following IEEE to the instructions, it may limits. Dell Networking is
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 33
    -recommended modification of this product, including the fitting of non-Dell EMC option cards. This product has been tested and found , you may be required to take adequate measures. European Community Contact Dell EMC, EMEA - Central Dahlienweg 19 66265 Heusweiler Germany http://www.force10networks
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 34
    used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. NOTE: Use the AC power cords with Dell EMC equipment only. Do not use Dell Force10 AC power cords with any unauthorized hardware. Figure 17. Japan Warning Label
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 35
    User's Guide ● services in several countries to assist equipment owners in recycling their IT products. Waste Electrical and Electronic Equipment (WEEE) Directive for Recovery, Recycle and Reuse of IT and Telecommunications Products Dell EMC switches end of life per this Directive. Specifications 35
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 36
    collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE information on Dell EMC product recycling offerings, see the WEEE Recycling instructions on Support. For more information, contact the Dell EMC Technical
  • Dell S3048-ON | EMC PowerSwitch Installation Guide March 2022 - Page 37
    tag or express service code, pull out the tag or enter the show chassis command from the CLI. ● To receive more technical support, click Contact Us. On the Contact Information web page, click Technical Support. To access switch documentation, go to www.dell.com/manuals/. To search for drivers
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

Dell EMC PowerSwitch S3048-ON
Installation Guide
March 2022
March 2022
Rev. A10