Dell S5296F-ON EMC PowerSwitch S5200-ON Series BMC User Guide March 2021
Dell S5296F-ON Manual
View all Dell S5296F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell S5296F-ON manual content summary:
- Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 1
Dell EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 March 2021 Rev. A03 - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 2
Copyright © 2018 - 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 3
Contents Chapter 1: About this guide...4 Information symbols...4 Document revision history...5 Chapter 2: Hardware and software support 6 Chapter 3: Configuration methods 7 Configurations...9 Date ipmiutil package...38 Chapter 9: Access FRU data...39 Chapter 10: Dell EMC support...41 Contents 3 - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 4
this guide before you install and power on this equipment. This equipment contains two power cables. Disconnect both power cables before servicing. NOTE: This guide may contain language that is not consistent with the current guidelines. Dell EMC plans to update the guide over subsequent releases - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 5
. Updated document to current IDD standards. Added language note. Updated the Default configuration restore section. Added the ipmi commands section. Fixed incorrect link. About this guide 5 - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 6
2 Hardware and software support For the most current BMC update information, see the S5200-ON The BMC out-of-band (OOB) network or LAN is not enabled for Trade Agreement Act-qualified (TAA) switches. The BMC OOB is enabled for non-TAA-qualified switches. Required drivers In Linux, the baseboard - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 7
The diagnostic operating software (DIAG OS) running on the local processor has ipmitool installed by default. You can use the ipmitool both at the switch and remotely. Accessing BMC from the host does not require user name or password. The general syntax for using ipmitool is: NOTE: -I and -H are - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 8
INTER_5.0V_volt | 4.900 INTER_3.3V_volt | 3.300 FPGA_1.0V_volt | 0.990 FPGA_1.2V_volt | 1.190 FPGA_1.8V_volt | 1.780 FPGA_3.3V_volt | 3.200 BMC_2.5V_volt | 2.400 BMC_1.15V_volt | 1.150 BMC_1.2V_volt | 1.210 SWITCH_6.8V_volt| 7.000 SWITCH_3.3V_volt| 3.300 SWITCH_1.8V_volt| 1.790 USB_5. - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 9
die.net/man/1/ipmitool. NOTE: Throughout this user guide, Intelligent Platform Management Interface Specification Second Generation v2.0.pdf Parameters. In addition to setting IP addresses, use ipmitool to set the network mask, MAC address, default gateway IP and MAC addresses, and so forth - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 10
# ipmitool lan set 1 ipaddr You can also add the BMC IP address from the BIOS. For more information, see the BIOS manual at www.dell.com/support. DNS configuration Use these commands to set and get domain name server (DNS)-related settings, for example hostname, domain setting, and DNS - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 11
To override the date and time that is used in the system event log (SEL) log, use the following command: root@dellemc-diag-os:~# ipmitool sel time get 08/01/2018 15:10:46 root@dellemc-diag-os:~# ipmitool sel time set usage: sel time set "mm/dd/yyyy hh:mm:ss" root@dellemc-diag-os:~# For ipmiutil/ - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 12
, see the IPMI Specification v2.0 chapter 17.11 Alert Policy Table and chapter 30.3 Set PEF Configuration Parameters Command (parameter 9). LAN destinations BMC supports SNMP alert destinations. These are SNMP traps. When you set a LAN destination for alerts, the BMC sends an SNMP trap to the set - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 13
The following output using the ipmitool lan alert print command shows the configuration was successful: root@dellemc-diag-os:~# ipmitool lan alert print 1 1 Alert Destination : 1 Alert Acknowledge : Unacknowledged Destination Type : PET Trap Retry Interval : 0 Number of Retries : 0 Alert - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 14
Device (ID 0) Board Mfg Date : Mon Feb 12 08:00:00 2018 Board Mfg : Dell Board Product : Board Serial : CNCES0082C0002 Board Part Number : 0G1T60X01 Product Manufacturer : Dell Product Name : Product Version : 00 Product Serial : X1 14 Configuration methods - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 15
Board Mfg Date : Fri Jan 12 18:47:00 2018 Board Mfg : DELL Board Product : PWR SPLY,495W,RDNT,DELTA Board Serial : CNDED0081G01GL Board Part Privilege Limit. This determines the maximum privilege level that the user can to switch to on the specified channel. ■ 0h-reserved ■ 1h-Callback ■ 2h- - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 16
those bytes return as 0s. ● Response data byte 1-Completion code Set User Password Command ● Request data byte 1-User ID. For IPMI v20, the BMC supports 20-byte passwords (keys) for all user IDs that have configurable passwords. The BMC maintains an internal tag indicating if the password is set as - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 17
1-parameter selector ● Request data Byte 2-State selector ● Request data Byte 3:N-Configuration parameter data ● Response data Byte 1-Completion code ○ 80h-Parameter not supported ○ 81h-Invalid time (start/stop time) ○ 82h-Attempt to write read-only parameter ○ 83h-Attempt to access HTTP Port 80 To - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 18
Table 3. Firewall parameters (continued) Parameter # Add the Pv4 port number range rule 3 Remove the IPv4 address rule 4 Remove the range of IPv4 addresses rule 5 Remove the IPv4 port number rule 6 Remove the IPv4 port range rule 7 18 Configuration methods Parameter data ● 1 = UDP ● 2 - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 19
Table 3. Firewall parameters (continued) Parameter # Flush IPv4 and IPv6 iptable 8 Drop all 9 Remove drop all rule 10 Add IPv4 address with timeout rule 11 Add IPv4 range of addresses with 12 timeout rule Parameter data Flush all the rules set using iptables and ip6tables. Add iptables - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 20
Table 3. Firewall parameters (continued) Parameter # Add the IPv4 port number with timeout 13 rule Add the IPv4 port range with timeout 14 rule 20 Configuration methods Parameter data ● LS-byte first if little endian system. Two-byte data required to form year. Data 1-Protocol TCP and UDP ● - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 21
Table 3. Firewall parameters (continued) Parameter # Remove the IPv4 address with timeout 15 rule Remove the range IPv4 address with 16 timeout rule Remove the IPv4 port number with 17 timeout rule Parameter data Data 1:4-IP address ● MS-byte first. The IPv4 address type blocked or - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 22
Table 3. Firewall parameters (continued) Parameter # Remove the IPv4 port number range 18 with timeout rule Drop all IPv4 or IPv6 with timeout rule 19 22 Configuration methods Parameter data ● 6-month ● 7-date ● 8-hour ● 9-minute ● Date 10-15-stop time ● [10:11]-Year ● LS-byte first if - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 23
Table 3. Firewall parameters (continued) Parameter # Remove drop all Ipv4 or IPv6 with 20 timeout rule Add IPv6 address with timeout rule 21 Parameter data ● 7-minute ● Date 8:13-Stop time ● [8:9]-Year ● LS-byte first if little endian system. Two-byte data required to form year. ● 10-month ● - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 24
Table 3. Firewall parameters (continued) Parameter # Add IPv6 address range with timeout 22 rule Remove the IPv6 address with timeout 23 rule Remove the Ipv6 address range with 24 timeout rule 24 Configuration methods Parameter data Data 1:16-IPv6 address range ● [1:16]-Port number from - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 25
Table 3. Firewall parameters (continued) Parameter # Add the IPv6 port number with timeout 25 rule Add the IPv6 port number range with 26 timeout rule Parameter data ● 35-month ● 36-date ● 37-hour ● 38-minute ● Date 39:44-stop time ● [39:40]-Year ● LS-byte first if little endian system. Two- - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 26
Table 3. Firewall parameters (continued) Parameter # Remove the IPv6 port number with 27 timeout rule Remove the IPv6 port range with 28 timeout rule 26 Configuration methods Parameter data ● Date 12-17-stop time ● [12:13]-Year ● LS-byte first if little endian system. Two-byte data - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 27
Table 3. Firewall parameters (continued) Parameter # Add the IPv6 address rule 29 Add the IPv6 address range rule 30 Remove the IPv6 address rule 31 Remove the IPv6 address range rule 32 Add the IPv6 port number rule 33 Add the IPv6 port number range rule 34 Remove the IPv6 port - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 28
Table 3. Firewall parameters (continued) Parameter # Remove the IPv6 port number range rule 36 Parameter data ● [2:3]-Port number from the ports blocked or unblocked based on the state. Data 1-Protocol TCP and UDP ● 0 = TCP ● 1 = UDP ● 2 = both TCP and UDP ● Data 2:5-port number ● [2:3]-Port - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 29
● Netfn-0x32 ● Command-0x68 Audit log configuration ● Request data byte 1-Cmd ○ [7:2] Reserved ○ [1:0] 01h-Audit log ● Request data byte 1-Status ○ [7:2] Reserved ○ [1:0] 01h-Disabled ○ 01h-Enable local ● Response data byte 1-00h-success ○ CCh=invalid data field ○ FFh=unspecified error ● - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 30
a switch restore. Table 4. Default settings after a switch restore -TAA and disabled for TAA BMC supports unique password Yes BMC OOB username/ network time protocol (NTP) ○ [2]-1b: Backup IPMI. 0b: Do not backup IPMI ○ [1]-1b: Backup NETWORK And SERVICES. 0b: Do not backup NETWORK And SERVICES - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 31
The following are host power control commands: ● Power Off-the ipmitool powers off ● Power On-the ipmitool powers on ● Power Cycle-the ipmitool power cycles ● Hard Reset-the ipmitool power resets 4 Host power control Host power control 31 - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 32
5 Firmware update To update the firmware from a remote machine, use the BMC LAN interface. You can also update the firmware in the local host OS using the USB interface. The USB interface is between the BMC and the microprocessor. When using the USB, the BMC simulates a virtual USB device, then - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 33
6 Access system health sensors To check sensor information, use the following command: root@dellemc-diag-os:~# ipmitool sensor list To change the sensor threshold, see the IPMI Specification v2.0 chapter 35.8 Set Sensor Thresholds Command. ● Request data byte 1-Sensor number, FFH=reserved ● Request - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 34
FAN3_prsnt | 0x0 FAN4_prsnt | 0x0 FAN1_Rear_stat | 0x0 FAN2_Rear_stat | 0x0 FAN3_Rear_stat | 0x0 FAN4_Rear_stat | 0x0 FAN1_Front_stat | 0x0 FAN2_Front_stat | 0x0 FAN3_Front_stat | 0x0 FAN4_Front_stat | 0x0 INTER_5.0V_volt | 4.900 INTER_3.3V_volt | 3.300 FPGA_1.0V_volt | 0.990 FPGA_1. - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 35
● ipmi chassis bootdev bios ● ipmi event ● ipmi event file ● ipmi event event [event_dir] ● ipmi mc reset ● ipmi mc guid ● ipmi mc info ● ipmi mc watchdog get ● ipmi mc watchdog reset IPMI commands 35 - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 36
● ipmi mc watchdog off ● ipmi mc selftest ● ipmi mc getenables ● ipmi mc getenabled ● ipmi mc getsysinfo system_fw_version ● ipmi mc getsysinfo primary_os_name ● ipmi mc getsysinfo os_name ● ipmi mc getsysinfo system_nam ● ipmi mc - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 37
● ipmi sol payload [channel][userid] ● ipmi sol activate [][instance=] ● ipmi sol deactivate [instance=] ● ipmi sol looptest [[[]]] ● ipmi user summary [] ● ipmi user list - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 38
BMC. ○ ipmiutil hpm (ihpm)-hardware platform management (HPM) firmware update manager extensions ○ ipmiutil lan (ilan)-show and configure the local area network (LAN) port and platform event filter (PEF) table to generate BMC LAN alerts using the firmware events. ○ ipmiutil picmg (ipicmg)-discover - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 39
implements as a device on a shared bus. ○ Software can elect to retry the operation after a minimum of 30 milliseconds if the code returns. Dell Technologies recommends that the management controllers incorporate built-in retry mechanisms. Generic IPMI does not take advantage of this completion code - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 40
Board Part Number : 07R5RFX01FRU Device Description : FAN4_fru (ID 6) Board Mfg Date : Mon Jan 1 00:00:00 1996 Board Serial : CN07R5RFCES0084N0082 Board Part Number : 07R5RFX01 40 Access FRU data - Dell S5296F-ON | EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 41
network outages. Through the support site you can obtain technical information, access software upgrades and patches, download available management software, and manage your open cases. The Dell EMC support site provides integrated, secure access to these services. To access the Dell EMC support
Dell EMC PowerSwitch S5200-ON Series
BMC User Guide
March 2021
March 2021
Rev. A03