Dell S5296F-ON EMC Networking OS10 Enterprise Edition Switch Configuration Gui
Dell S5296F-ON Manual
View all Dell S5296F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell S5296F-ON manual content summary:
- Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 1
Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON Deploying S5148F-ON switches for a VxRail 4.5 cluster and S5200F-ON switches for a VxRail 4.7.0 cluster. Abstract This document provides Dell EMC Networking OS10 Enterprise - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 2
may be trademarks of their respective owners. Dell believes the information in this document is accurate as of its publication date. The information is subject to change without notice. 2 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 3
...6 1.1 Supported switches and operating systems...7 1.2 Typographical conventions...8 1.3 Attachments...8 2 Hardware overview...9 2.1 Dell EMC Networking S5248F-ON ...9 2.2 Dell EMC Networking S5232F-ON ...9 2.3 Dell EMC Networking S5148F-ON ...9 2.4 Dell EMC Networking S3048-ON ...9 2.5 Dell EMC - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 4
S5248F-ON and S5232F-ON using VxRail 4.7.0 47 B.1 Dell EMC Networking switches...47 B.2 DAC Cables ...47 B.3 VxRail E560 nodes ...47 B.4 VxRail appliance software ...48 4 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 5
port-groups for S5248F-ON ...50 D.2 Breakout interfaces for S5232F-ON ...51 D.3 Auto-breakout feature ...51 E Technical resources ...52 F Support and feedback ...53 5 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 6
• A single Dell Networking switch. This document provides switch topology options and configuration examples for a VxRail 4.5 cluster using nodes built on 14th generation (14G) PowerEdge servers. Nodes in these examples use 25GbE network adapters. Switches in this guide use Dell EMC Networking OS10 - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 7
provided in this deployment guide use VxRail 4.5 nodes connected to Dell EMC Networking S5148F-ON switches running Dell Networking OS10EE. This document also includes examples for S5248FON and S5232F-ON with VxRail 4.7.0. Dell EMC Networking supports the following switch and OS combinations for - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 8
document in .pdf format includes switch configuration file attachments. To access attachments in Adobe Acrobat Reader, click the icon in the left pane halfway down the page, then click the icon. 8 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 9
S5248F-ONs as leaf switches. 2.2 Dell EMC Networking S5248F-ON Dell EMC Networking S5232F-ON The S5232F-ON is a 1-RU, multilayer switch with 32x100GbE and 2x10GbE ports. This guide uses two S5232F-ONs as leaf switches. 2.3 Dell EMC Networking S5232F-ON Dell EMC Networking S5148F-ON The S5148F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 10
factor. 2.5.4 Dell EMC VxRail E Series node VxRail E Series nodes are best suited for remote office or entry workloads. E Series nodes support up to 40 only, max 8 nodes/cluster) 10 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 11
(iDRAC) for OOB management. Note: P, V, and S Series nodes support additional network adapters in PCIe slots. See the Dell EMC VxRail Network Guide for more information. 11 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 12
-free topology and eliminates STP-blocked ports • Optimizes the use of all available uplink bandwidth • Guarantees fast convergence if either a link or a device fails 12 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 13
Enterprise Edition User Guide Release 10.4.1.0. 3.1.2 Dual switch without VLT The configuration of a switch pair without VLT is supported, but it does n Rack 1 Dual switch topology without VLT 13 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F- - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 14
it is not recommended as the switch becomes a single point of failure. S5148F-ON 12 VxRail node 1 12 VxRail node 2 12 VxRail node n Rack 1 Single switch topology 25GbE connections 14 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 15
, connections between leafs and spines, and routing protocols, see the Dell EMC Networking Layer 3 Leaf-Spine Deployment and Best Practices with OS10EE document. 15 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 16
VxRail and end-user traffic. In-band connections are covered in Section 3. Devices on the OOB management network in this guide use the 100.67.0.0/16 IP address block. 16 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 17
. This example uses two networks for VM data traffic, VM Network A and VM Network B, with each on a separate VLAN. The actual number of VM data networks used is based on customer requirements. 17 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 18
address Platform Services Controller hostname Platform Services Controller IP address Customer Supplied Platform Services Controller ( .16.11.254 Dell!234 P3ll!234 172.16.12.1 172.16.12.40 255.255.255.0 18 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 19
.local 172.16.11.3 vxhost04.dell.local 172.16.11.4 vxvcenter.dell.local 172.16.11.100 vxpsc.dell.local 172.16.11.101 vxman.dell.local 172.16.11.102 vxinsight.dell.local 172.16.11.103 19 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 20
jump box also provides DNS and NTP services for the VxRail cluster. It is connected to both leaf switches for redundancy using Microsoft Windows NIC teaming (switch-independent load balancing). 20 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 21
# show version S5148F-ON# show version Dell EMC Networking OS10-Enterprise Copyright (c) 1999-2018 by Dell Inc. All Rights Reserved. OS Version: 10.4.1.1 Build Version: 10.4.1.1.507 Note: Figure 1 at the beginning of this guide lists supported switches and operating systems for VxRail deployments - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 22
IP address via DHCP. The default username and password are both admin. Dell EMC recommends changing the admin password to a complex password during the first login. 22 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 23
using the spanning-tree rstp priority 0 command and S5148F-Leaf1B as the secondary RSTP root bridge using the spanning-tree rstp priority 4096 command. 23 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 24
. LLDP is useful for troubleshooting and validation. Dell EMC recommends leaving it enabled. General settings - dual switch with VLT S5148F-Leaf1A configure vlan1615 interface vlan1615 24 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 25
DNS and NTP services as covered in Section 5.4. If these services are located on other devices, ensure the switch interfaces connected to these services are configured in access vlan 1611 25 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 26
/1/53 description VLTi no switchport no shutdown interface ethernet1/1/54 description VLTi no switchport interface ethernet1/1/54 description VLTi no switchport 26 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 27
in the order shown. All commands are provided in the file attachments named S5148F-1A-no-vlt.txt and S5148F-1B-no-vlt.txt. 27 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 28
is useful for troubleshooting and validation. Dell EMC recommends leaving it enabled. General settings - dual switch without VLT S5148F- vlan1612 description vMotion no shutdown 28 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 29
DNS and NTP services as covered in Section 5.4. If these services are located on other devices, ensure the switch interfaces connected to these services are configured in access vlan 1611 29 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 30
-group 127 mode active command. When the configuration is complete, exit configuration mode and save the configuration with the end and write memory commands. 30 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 31
in the following sections are run to complete the switch configuration. The port numbers used in the configuration commands correspond to those shown in Figure 16. 31 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 32
on the in-band management network. Enable RSTP as a precaution against loops. Note: In OS10EE, LLDP is enabled on each interface and globally by default. LLDP is useful for troubleshooting and validation. Dell EMC recommends leaving it enabled. General settings - single switch S5148F-ON configure - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 33
and NTP services as covered in Section 5.4. If these services are located on other devices, ensure the switch interfaces connected to these services are configured /1/17 description Node1_Port1 33 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 34
switchport mode trunk switchport access vlan 1611 switchport trunk allowed vlan 1612-1615 spanning-tree port type edge flowcontrol receive on flowcontrol transmit on 34 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 35
vlan 1611 switchport trunk allowed vlan 1612-1615 spanning-tree port type edge flowcontrol receive on flowcontrol transmit on no shutdown end write memory 35 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 36
active U - Up (port-channel) F - Fallback Activated Group Port-Channel Type Protocol Member Ports 1000 port-channel1000 Eth STATIC 1/1/53(P) 1/1/54(P) 36 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 37
T Eth1/1/17-1/1/20 T Po1000 1614 Active VM_Network_A T Eth1/1/17-1/1/20 T Po1000 1615 Active VM_Network_B T Eth1/1/17-1/1/20 T Po1000 4094 Active T Po1000 37 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 38
topology, the output is identical to the above. For the single switch topology, the output includes all eight node-connected ports, and ports 1/1/53-54 are not used. 38 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 39
the backup link over the OOB management network. The Destination is the management IP address of the peer. The Peer HeartBeat status must be Up. S5148F-Leaf1A#show vlt 127 backup-link 39 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 40
-Leaf1A#show vlt 127 mismatch VLT-MAC mismatch: No mismatch Peer-routing mismatch: No mismatch VLAN mismatch: No mismatch VLT VLAN mismatch: No mismatch 40 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 41
NTP server. It may be connected to both leaf switches for redundancy using NIC teaming. Figure 18 shows a single connection from a jump box to a leaf switch for clarity. 41 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 42
to https://192.168.10.200 and deploy VxRail using the planning data in Table 3. Note: VxRail installation steps are beyond the scope of this guide. 42 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 43
allowed vlan 16121615,3939 interface ethernet1/1/19 switchport trunk allowed vlan 16121615,3939 interface ethernet1/1/20 switchport trunk allowed vlan 16121615,3939 43 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 44
configurations for single ToR switch, leaf switches in VLT and leaf switches in port channel. Note: To configure breakouts on S5248F-ON port groups or 5232F-ON interfaces, see Appendix D. 44 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 45
and firmware used to configure and validate the examples in this guide. Dell EMC Networking Switches Switches and OS versions Qty Item 2 Dell EMC Networking S5148F-ON leaf switches 1 Dell EMC Networking S3048-ON management switch OS Version 10.4.1.1 10.4.1.1 DAC Cables DAC cables used to - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 46
1 Patch 36, build 7388607 VMware vCenter Server Appliance 6.5 Update 1e, build 7515524 VMware vSAN 6.6.1 Patch 02 VMware vRealize Log Insight 4.3, build 5084751 46 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 47
the examples in this guide. Dell EMC Networking switches Switches and operating systems versions Qty Item 2 Dell EMC Networking S5248F-ON leaf switches 2 Dell EMC Networking S5232F-ON leaf switches 1 Dell EMC Networking S3048-ON management switch operating systems version 10.4.2.0 10 - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 48
ESXi 6.7.0 build 10302608 VMware vCenter Server Appliance 6.7.0 build 10244857 VMware vSAN vSAN 6.7 Update 1 VMware vRealize Log Insight 4.6.0, build 8080673 48 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 49
must allow this traffic. Not explicitly configured on Dell EMC Networking switches. Note: For additional VxRail nodes and rNDC configurations, see the Dell EMC VxRail Network Guide. 49 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 50
-pg-1/1/2)# do show port-group Port-group Mode Ports FEM port-group1/1/1 Eth 25g-4x 1 2 3 4 - port-group1/1/2 Eth 10g-4x 5 6 7 8 - ---Output Truncated--- 50 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 51
pluggable media and provide the needed breakouts, globally enable the autobreakout feature using the following command: S5248F-Leaf1A(config)# feature auto-breakout 51 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 52
for Dell EMC Networking S5148F-ON Manuals and documentation for Dell EMC Networking S5248F-ON Manuals and documentation for Dell EMC Networking S5232F-ON Dell EMC Networking Layer 3 Leaf-Spine Deployment and Best Practices with OS10EE Dell EMC VxRail Network Guide Dell EMC VxRail support and - Dell S5296F-ON | EMC Networking OS10 Enterprise Edition Switch Configuration Gui - Page 53
.com/support Telephone: USA: 1-800-945-3355 Feedback for this document We encourage readers to provide feedback on the quality and usefulness of this publication by sending an email to [email protected]. 53 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide
Dell EMC Configuration and Deployment Guide
Dell EMC Networking OS10 Enterprise Edition
Switch Configuration Guide for VxRail featuring
S5248F-ON, S5232F-ON and S5148F-ON
Deploying S5148F-ON switches for a VxRail 4.5 cluster and
S5200F-ON switches for a VxRail 4.7.0 cluster.
Abstract
This document provides Dell EMC Networking OS10 Enterprise Edition
switch configuration examples and topology options for a VxRail 4.5
cluster deployment using S5148F-ON. The document also includes a
VxRail 4.7.0 cluster deployment using S5248F-ON and S5232F-ON.
November 2018