    DENON AVR control protocol Application model :ɹTU-604CI Application terminal: RS-232C/ Ethernet Connector specification ɹᶗ. RS-232C Connector type: DB-9pin female type, slave straight connection (DCE type) ( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
  • Denon TU-604CI | Serial Protocol - Page 2
    ᶘ. Ethernet Connector type ɿ RJ-45(10BASE-T/100BASE-TX) Communication format ɿ ɹɹɹɹ Communication system ɹɹɹɹ Communication speed ɹɹɹɹ Communication port ɹɹɹɹ Communication data length : A half duplex : 10Mbps/100Mbps : TCP port 23 (telnet) : 135bytes (maximum) ɹ 29.May.2008 2/17
  • Denon TU-604CI | Serial Protocol - Page 3
    Option Setup > RS-232C Power " (3)Set parameters described below. "ON" --- Use this setting when using the TU-604CI connected in a network. ɹ "OFF"--- Use this setting when not using the TU-604CI connected in a network. This setting is reducing the power consumption in the standby mode. 29.May
  • Denon TU-604CI | Serial Protocol - Page 4
    AVR) if the 'request command' ( COMMAND+? +CR (0x0D)) has came from a controller. The RESPONSE should be sent within 200ms of receiving the COMMAND . *The form of RESPONSE presupposes that it is the same as that of EVENT . Basic specification . SI : Select Input source MS : surround Mode Setting
  • Denon TU-604CI | Serial Protocol - Page 5
    the meaning of 0x0D. SIDVD : Select Input source DVD MSSTEREO : surround Mode Set to STEREO MVUP : Master Volume UP PWON : system PoWer ON PWSTANDBY : system PoWer STANDBY SI? : Request command for now playing input source >> Return RESPONSE 'SI***' 29.May.2008
  • Denon TU-604CI | Serial Protocol - Page 6
    29.May.2008 Others A) COMMAND is receivable also during transmission of EVENT . B) Since CHANNEL described in B) ) returns as EVENT . E) When SURROUND MODE is the same in between INPUT source change before and after, EVENT of SURROUND MODE and CHANNEL VOLUME does NOT return. F) Although EVENT
  • Denon TU-604CI | Serial Protocol - Page 7
    ON change STANDBY Each Tuner STANDBY change ? Return PW Status S*:Slot-1=>S1 *mark is Target slot No. COMMAND SI TU1 TU2 TU3 TU4 TU5 TU6 ? PARAMETER function Select source (Change Display) Return SI Status example PWON PWSTANDBY PW? example PWS*ON PWS*STANDBY
  • Denon TU-604CI | Serial Protocol - Page 8
    COMMAND PARAMETER SY REMOTE LOCK ON REMOTE LOCK OFF REMOTE LOCK ? PANEL LOCK ON PANEL LOCK OFF PANEL LOCK ? ˞Tuner Type Check COMMAND TU S* ? ? PARAMETER "Cursor Up" Control "Cursor Down" Control "Cursor Left" Control "Cursor Right" Control "Enter" Control "RETURN" Control "GUI Menu
  • Denon TU-604CI | Serial Protocol - Page 9
    TM Status ANAUTO ---Tuning mode set to AUTO mode ANMANUAL ---Tuning mode set to MANUAL mode AN S* ? Return RDS Status - PS NAMEɺPTY TF, TP, TM COMMAND : '*' parameters can NOT operate when INPUT source isn't TUNER. 29.May.2008 example TFS*ANUP TFS*ANDOWN TFS*AN105000 (1050
  • Denon TU-604CI | Serial Protocol - Page 10
    ˞XM Control(North America model only) COMMAND PARAMETER TF S* XMUP XMDOWN XM*** (3 digits) XM? TP S* XMUP XMDOWN XM**(PRESET No.) XM? XMMEM XM S* ? function XM Channel UP XM Channel DOWN --- ***:XM CH No. Return TFXM Status XM PRESET CH UP XM PRESET CH DOWN XM PRESET CH direct change
  • Denon TU-604CI | Serial Protocol - Page 11
    ---Tuning mode set to AUTO mode TMS*HDAUTO ---Tuning mode set to MANUAL mode TMS*HDMANUAL Return HD Status HDS*? ---BAND, STATION NAME, STATION LONG NAME, MULTI CAST CURRENT, MULTI CAST PROGRAM, SIGNAL LEVEL,ARTIST, TITLE,ALBUM, GENRE, PROGRAM TYPE, NA ✓ ✓ ✓ PRESET EU
  • Denon TU-604CI | Serial Protocol - Page 12
    ˞DAB Control(Europe model only) COMMAND PARAMETER TF S* DAUP DADOWN DA? TP S* DAUP DADOWN DA**(PRESET No.) DA? DAMEM TM S* DAENS DAALPHA DAAS DAFS DA? DA S* ? 29.May.2008 function example NA DAB Channel UP TFS*DAUP DAB Channel DOWN TFS*DADOWN Return TFDAB Status
  • Denon TU-604CI | Serial Protocol - Page 13
    TU1 TU2 TU3 TU4 TU5 TU6 PARAMETER function Select source (Change Display) ˞Tuner Type Check EVENT PARAMETER TU S* AN S* XM S* HD S* DA S* NO function Tuner-Type is ANALOG TUNER Tuner-Type is XM Tuner-Type is HD RADIO Tuner-Type is DAB Tuner-Type is NONE 29.May.2008 example PWON
  • Denon TU-604CI | Serial Protocol - Page 14
    Frequency change kHz at AM band ****.** MHz at FM band TUNER PRESET change to No.** TUNER BAND change---Band set to AM TUNER BAND change---Band set to FM TUNER MODE change---Tuning mode set to AUTO mode TUNER MODE change---Tuning mode set to MANUAL mode RDS PS NAME RDS Program Type 29.May.2008
  • Denon TU-604CI | Serial Protocol - Page 15
    ˞XM Control(North America model only) EVENT PARAMETER TF S* XM*** (3 digits) XMCMP TP S* XM**(PRESET No.) XM S* CH NAME ******** (8 digit) ARTIST (16 digit) TITLE (16 digit) XMID ******** (8 SIGNAL GOOD SIGNAL WEAK SIGNAL MARGINAL SIGNAL NOSIGNAL --- ***:XM CH No. function
  • Denon TU-604CI | Serial Protocol - Page 16
    MHz at FM band (
  • Denon TU-604CI | Serial Protocol - Page 17
    (MONO/STEREO) change DAB MODE(MONO/STEREO) change DAB SIGNAL QUALITY change DAB TIME display (only when request("DAB?") is received) DAB DATE display(only when request("DAB?") is received) example TFS*DA5A ɺTFDA12C TFS*DACMP TPS*DAA1 (PRESET No."A1") TMS*DAENS TMS*DAALPHA
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

29.May.2008
DENON AVR control protocol
Ver.
5
.
6
.0
Application model : TU-604CI
Application terminal: RS-232C/ Ethernet
Connector specification
. RS-232C
Connector type:
DB-9pin female type, slave straight connection (DCE type)
( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
Communication format:
Synchronous system
: Tone step synchronization
Communication system
: A half duplex
Communication speed
: 9600bps
Character length
: 8 bits
Parity control
: None
Start bit
: 1 bit
Stop bit
: 1 bit
Communication procedure
: Non procedural
Communication data length
: 135 bytes (maximum)
1/17