    SETTING SERVICE DATA SHEET Type A with Run / Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient Operating Time Freezer Temperature Refrigerator Contact TID before replacing main control board. • Refer to Service Manual for additional information. Electrical 115 vac (127 vac max)
  • Electrolux E23BC79SPS | Timer Guide English - Page 2
    WHT/BRN WHT/BLU J1-3 J1-1 LED POWER BOARD 4 GRY 3 2 ORN 1 GRY 4 GRY 3 ORN 2 ORN 1 RG-9 LED RG-8 LED PTD LEDS J4-3 J4-4 ERF2500++ISO REFRIGERATOR CONTROL FREEZER LEDS 4 WHT/GRN 3 2 WHT/RED 1 WHT/GRN 4 WHT/GRN 3 WHT/RED 2 WHT/RED 1 LED FZ-2 LED FZ-1 TYPICAL LED CONNECTOR 1 AT1, IM1, MB1
  • 1
  • 2

SERVICE DATA SHEET
A06156001
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch
to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive
heat will distort the plastic liner.
POWER
ICE MAKER
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
THERMAL
CUT-OUT
HOLD
SWITCH
THERMOSTAT
SHUTOFF
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUNTING
PLATE
165 WATTS
MOTOR
NEUTRAL
BLK
BLK
BLK
BLU
C
C
C
NO
NO
NO
NC
NC
NC
YELLOW
BRN
RED
GRN / YEL
RED
RED
LT. BLUE
P-3
P-1
P-2
P-4
ICE MAKER
LT. BLUE
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
90 to 100%
100%
Freezer Temperature
-5° to 2°F
(-20° to -17°C)
-1° to 3°F
(-18° to -16°C)
Refrigerator Temperature
34° to 39°F
(1° to 4°C)
34° to 39°F
(1° to 4°C)
Low Side Pressure
-2 to 6 psig
(-14 to 41 kPa)
-2 to 6 psig
(-14 to 41 kPa)
High Side Pressure
(last 1/3 cycle)
85 to 105 psig
(586 to 724 kPa)
120 to 135 psig
(827 to 931 kPa)
Wattage (last 1/3 cycle)
30 to 50
50 to 70
Amps (running)
.4 to .8
.7 to .9
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size:
27’ & 28’ SD,
22’ CD
Thermal Cutout
Heater
Defrost
Thermistor
Termination
Cut-in
Cut-out
Watts
Ohms
Cut-out
Freezer
110°F
(43.3°C)
135°F
(57.2°C)
500
26.5
48°F
(8°C)
Fresh Food
Ice Maker
110°F
(43.3°C)
135°F
(57.2°C)
70
188.9
68°F
(20°C)
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage
115 vac
ERROR CODES
SPECIAL MODES
Display
Interpretation
Mode
Display
Activate
Deactivate
FZ
FF
FZ
FF
(press for up to 10 sec. simultaneously)
--
OP
Open FF Cavity
Thermistor
Manual Defrost
d
F
FF + and FF -
Same to deactivate
OP
--
Open FZ Cavity
Thermistor
Demo / Showroom
77
77
FZ + and FF -
Unplug to deactivate
--
SH
Shorted FF Cavity
Thermistor
Sabbath
Sb
Sb
FZ - and FF +
Same to deactivate
SH
--
Shorted FZ Cavity
Thermistor
System Diagnostic
No FF or FZ display,
all UI LEDs on
FZ + and FF -
Press and hold FF +
to deactivate
SY
CF
UI to Main Board
communication failure;
on start up
Current Air Temps
FZ Temp
FF Temp
FZ - and FF +
and Water
Automatically
after 10 sec
SY
CE
UI to Main Board
communication error; af-
ter a period in operation
FFIM Diagnostic
Numerical display of
first test
FZ + and FF +
Press and hold FF +
to deactivate
SY
EF
Freezer Evaporator
Fan Failure
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
FRESH FOOD ICE MAKER DIAGNOSTIC MODE
Activate:
Press
FZ UP
and
FF UP
temperature pads for up to 10 sec. simultaneously.
Press
FF UP
or
FF DOWN
to move forward or backward through tests.
Deactivate:
Press
FF UP
for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
NOTE: Silence alarm.
Test
To activate test
Passing Result
52C
Ice Maker Thermistor
Activates
automatically
FZ display shows temperature sensed by Ice Maker Thermistor.
“OP” if open; “SH” if short
55C
Water Valve
Press power
on-off
Remove ice tray to collect water into a measuring container to measure water
fill. If collecting water into ice tray, first perform test 63C to empty ice tray.
57C
Evaporator Fan (FFIM)
Press power
on-off
“On” on FZ display when fan activated, “OFF” when deactivated.
58C
Ice Level Sensor
Activates
automatically
Remove ice bucket.
Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position.
Hold bail arm up. Pass if alarm sounds when tray returns to “home” position.
This test runs continuously until another test is selected.
63C
Twist Tray
Press power
on-off
Remove ice bucket.
FZ display shows “1” and “GOOD”.
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
SYSTEM DIAGNOSTIC MODE
Activate:
Press
FZ UP
and
FZ DOWN
for up to 10 sec. simultaneously. Press
FF UP
to advance through tests.
Deactivate:
Press
FF UP
for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
Passing result
--
First Screen
--
All LEDs on UI illuminated, except digit displays.
--
Second Screen
--
All segments of UI digit displays illuminated.
--
Third Screen
--
Blank UI display, no LEDs illuminated.
28
Dispenser Paddle
Press disp. paddle
“on” on UI when depressed; “off” when released
34
Ambient Thermistor
@ UI
Activates automatically
UI shows temperature sensed at UI; Pass if within +20˚F/-10˚F of tem
-
perature measure with gauge at UI location. “OP” if open; “SH” if short.
46
Humidity Sensor
Activates automatically
“OP” if open, “SH” if short. AC Heater System: Displays %RH. DC Heater Sys-
tem: “HI” - heater should be on. “Lo” - heater should be off. %RH is displayed
when humidity is between “Lo” and “HI” values; heater could be on or off.
2
Freezer Defrost
Heater
Press power on-off
Freezer defrost heater on when “on”; off when “off”. Evaporator thermistor
temperature is flashed. Watch for temp increase with the heater on. It may
take a few minutes for the evaporator to heat up.
3
FF Lights powered by
external board
Press power on-off
FF lights on when “on”; off when “off”
8
Water Valve
(Dispenser)
Press power on-off
FF door must be closed.
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”
10
Auger Motor
Press power on-off
FF door must be closed. Motor running when “on”; motor stopped when “off”
11
Cube/Crush Solenoid
Press power on-off
FF door must be closed.
Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”.
12
Condenser Fan
Press power on-off
Fan running when “on”; stopped when “off”
41
Perfect Temp Drawer
(PTD)
Press power on-off
PTD UI illuminated when “on”, off when “off”
43
Mullion Anticondensa-
tion Heater
Press power on-off
Flip mullion heater and dispenser pocket heater on when “on”; off when “off”
38
VCC Compressor
Press power on-off
Compressor running when “on”; off when “off”
15
Freezer Evapora-
tor Fan
Press power on-off
Press to toggle between “off”, “LO” and “HI”. A current sensor reading is flashed
(units are not mA). OFF reading should be around 2. “LO” speed reading should
settle down to around 9. “HI” speed reading should settle down above 40.
20
FZ Lights
Press power on-off
FZ lights on when “on”, off when “off”
22
Damper
Press power on-off
Perform test 15 and set fan to “HI”. Then check for air flow when open
“OP”; and no air leaks when closed “CL”
36
Ice Chute Door
Depress ice chute door
or press power on-off
“OP” on UI when manually opened; “CL” when closed. Or using “Power On-
Off,” “OP” on UI when solenoid activated; “CL” when deactivated.
23
FF Door
Open/Close FF door
“CL” on UI when door closed; “OP” when open
24
FZ Door
Open/Close FZ door
“CL” on UI when door closed; “OP” when open
26
Ice Maker Defrost
Heater
Activates automatically
Heater is turned on automatically. The ice maker evaporator thermistor
temperature is flashed. Watch for temp increase with the heater on. It may
take a few minutes for the evaporator to heat up.
29
FF Thermistor
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of tempera-
ture measured with gauge at FF thermistor location. “OP” if open; “SH” if short
30
FZ Thermistor
Activates automatically
UI shows temperature sensed by FZ thermistor; pass if within 10°F of tempera-
ture measured with gauge at FZ thermistor location.“OP” if open; “SH” if short
33
Ambient Thermistor
@ Main Board
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/-10°F of tem-
perature measured with gauge at main board location. “OP” if open; “SH” if short
39
Freezer Evaporator
Thermistor
Activates automatically
UI shows temperature sensed by freezer evaporator thermistor; pass if
within 10°F of temperature measured with gauge at evaporator thermistor
location.“OP” if open; “SH” if short
45
Ice Maker Mold
Thermistor
Activates automatically
UI shows temperature sensed at ice maker; pass if within +20°F/-10°F of tem-
perature measured with gauge at ice maker mold. “OP” if open; “SH” if short
68
Ice Maker Evaporator
Thermistor
Activates automatically
UI shows temperature sensed by evaporator thermistor; pass if within 10°F
of temperature measured with gauge at evaporator thermistor location.
“OP¯” if open; “SH¯” if short
0-
Firmware Parameters
Press power on-off
Displays digit sequence; record
1-
Main Board Firmware
Press power on-off
Displays digit sequence; record
3-
UI Firmware
Press power on-off
Displays digit sequence; record
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not
attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling:
Remove cover by inserting screwdriver in notch at bot-
tom and prying cover from housing. Use screwdriver to rotate motor
gear counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.
Water Fill Volume:
The water fill adjustment screw will change
the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is
102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill
volume must be checked.
Service Mode For Perfect Temp™ Drawer
Activation
This mode is acces-
sible only when the
drawer is in OFF mode.
Press and hold the
temperature decrease
key (–) and the tem
-
perature increase key
(+) for 5 seconds.
Deactivation
Press and hold the
temperature (+) key
for 5 seconds, or no
keys pressed in 5 min-
utes returns to the OFF
mode of operation.
Test Operation
The up/down buttons
will be used to navigate
through the tests and
the ON/OFF button will
be used to initiate the
displayed test.
Fan Test
Display shows “F1” for fan
on or “F0” for fan off.
Heater Test
Display shows “H1” for heater
ON or “H0” for heater OFF.
Damper Test
Display shows “d1”
for damper open,
or “d0” for damper
closed. Damper
movement may take
30 seconds.
To Test Damper
1. Remove drawer.
2. Start damper test.
3. Observe damper
moving open
and closed.
4. Exit damper test.
Report NTC Temperature
Test
Display shows “b1” for
chamber sensor
test. The UI display will show
—°F until the main board
responds with associated
sensor temperature reading.
Display Test
“L0” for display test. The display
test will cycle through all the
display segments with a minimal
on time for each segment.
Fault Codes Listed on Diagram Sheet
FRESH FOOD ICE MAKER FILL TIME ADJUSTMENT MODE
NOTE: First consider water filter condition before adjusting fill time.
Activate:
Press and hold the
Water
and
Crush
pads for up to 10 seconds.
Press
FF +
or
FF -
to adjust between the 3 fill settings.
Deactivate:
Exits automatically after 10 seconds, or press any button other than + or -.
Display
Description
FZ
FF
ICE
Min Fill Time (default)
=
Mid Fill Time
=
Max Fill Time
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
VCC COMPRESSOR MOTOR RESISTANCE CHECK