    Instructions with owner. OWNER: Read your dishwasher Use and Care Guide. It contains important safety information for operating this appliance. It also has many suggestions for getting the best results from your dishwasher (See Step 4) All the parts can be found at local water supply. Review Figure 4
  • Electrolux EDW7505HSS | Installation Instructions - Page 2
    To prevent the possibility of damage to dishwasher, replace factory installed outer door screws with factory supplied wood panel screws, The EDW7505HSS & EDW7505HPS can be installed with a fully integrated, buyer supplied custom door panel. The custom panel should be 1/2" to 3/4" (19mm) thick. Items
  • 1
  • 2

Dishwasher
Installation
Instructions
Printed in U.S.A.
154744001
10/10
INSTALLER:
Leave
Installation
Instructions
with owner.
OWNER:
Read your dishwasher
Use and
Care
Guide.
It contains
important
safety information
for operating
this appliance.
It also has
many suggestions
for getting the best results from your dishwasher.
Read
all instructions
before
installing
dishwasher.
For your safety, please read and observe
all safety
instructions.
This
guide will help you anticipate
drain,
water,
and
electrical
connections,
and help you select
the
best
location
for
the
dishwasher.
Tip
Over
Hazard
Do not use dishwasher
until completely
installed.
Do not push down on open door.
Failure to
follow
this warning
can result in serious
injury.
Cut
Hazard
To prevent serious
injury
from
sharp
edges,
wear work
gloves when handling,
unpacking
or disassembling
unit.
Tools and Materials
Needed for
Installation
(Not
Included)
Drill, Electric
Drill Bit 118"
Driver, Socket
8/32",114",8118"
Flaring Tool/Tube
Cutter (for copper tubing)
Flashlight
Level
Pipe Joint Compound
(for iron pipe plumbing) or
Pipe Thread Tape (for sealing threads)
Pliers
Safety Glasses
Saw, Keyhole or Vf,
1_/2"to 2" Hole Cutters
Screw Drivers, Slotted and #2 Phillips
(magnetic tip
preferred)
Tape, Electrical
or Duct
Tape, Measuring
Wire Stripper or Utility Knife
Wrench,
Hex-end
Wrenches,
2 Adjustable
(for copper tubing)
or 2 Pipe wrenches
(for iron pipe plumbing)
Parts You Will Need*
(Not Included)
Drain Hose Clamp, 1W' Diameter
Brass Elbow,
90 ° with a 3/8"National Pipe Thread
• Conduit Connector
(UL Listed)
• Wire Nuts, three (3) for 12-14 gauge wire (UL Listed)
If required:
• "Y" Branch Tailpiece and
Connector
Kit (See Step 4)
• Air Gap Kit (See Step 4)
All the parts can be found at local hardware,
electrical
and
plumbing
supply stores.
Electric
Shock
Hazard
Disconnect
electrical
power at the
fuse
box or
circuit breaker box before
beginning
installation.
Failure to
follow
this warning
could result
in death
or serious
injury.
NOTE: Put unit on its back being careful not to pinch the
Water
Drain Hose.
1.
Remove two (2) screws at front of the kickplate assembly
using a
#2 Phillips screw driver.
2.
Tilt and pull forward to remove see figure 1.
NOTE:
It is not necessary
to remove the outer door for installation.
Outer
Door
Top Screws
Kickpiat_
Toeplate
Figure
1
Kickplate
Assembly
,
,
Locate water inlet valve behind kickplate on bottom left underside
of unit.See Figure
4. The valve has a V?' NPT female fitting.
Remove
Plug
Wrap 90 ° elbow (not included) with pipe thread tape (or apply
joint compound)
and thread it into water inlet valve.
When
tightened, elbow should point toward the left. To prevent bending
of bracket or breaking of valve, avoid overtightening.
See Figure
4.
Cabinet
Preparation:
As a precaution,
it is recommended,
but not required
that the
cabinets
enclosing
all sides of the dishwasher
(including
the
underside
of the countertop)
be sealed with an oil based
paint
or moisture-proof
polyurethane
to prevent possible steam/
moisture
damage.
Electric
Shock
Hazard
Observe all local codes and ordinances
for
electrical and plumbing connections.
All electrical
and plumbing work should be performed
by
qualified
persons. Failure to
follow
this warning
could result in death or serious
injury.
,
Make sure your location has the correct
drain, water, and
electrical
outlets to make the connections.
Do not install unit
under a
cooktop
range.
Damage
to tub or other
components
will
occur.
4%" max.
A
Figure 2
13/4"
Electricalwater
and
draidines
must
be confined
to shadedarea
Preferred
drain areas
(5/r
6"rain. clearance
required from unit to
underside of countertb
Front
*Heightonlyadjustable td N" max.when
installedin35tnax4tandardcabine#:utout
Left
_
245/8"_
//
/
,'
Doorin90
,,
open
position
\
waterinletandpowersu_pl_
location(middlebottomrear)
Figure
3
S
DIMENSIONS
DO
NOT
INCLUDE
INSLJ-ATION
-
INSLJ_ATION
BLANKET
MAY
BE COMPRESSED
UPON
INSTALLATION.
IMPORTANT:
For proper
operation
and appearance
of unit,
cabinet opening
should
have dimensions
as shown in Figure 2.
If unit is to be placed in a corner, there must be at least a 2-inch
side clearance to open door.
2.
Floor should be flat and free of any obstruction.
IMPORTANT:
Drain, water, and electrical
lines should
be
roughed-in
before
going any
further.
Electric
Shock
Hazard
Electrical,
water, and drain lines
must
be confined
to shaded areas in Figure
2.
Electric conductors,
water, and drain could be
damaged.
Failure to
follow
these instructions
could
result in
fire
or electric shock.
NOTE:
If dishwasher
is installed at end of a cabinet, sides and
back must be
fully
enclosed.
NOTE:
Cabinet
Seal
Kit
(Kit # 154662101).
This
kit
provides a
seal between the unit and cabinets once installation
is
complete.
(The Installation
Instructions
are located in the Kit)
Weight
Keep children
away
from
the
front
of the dishwasher
so
that they are not accidentally
hit by the door during
loading or unloading
or if door should
unexpectedly
open.
The weight of the door can cause injury.
Locating
the Connections
1.
Review dimensions
in Figure
2 to locate dishwasher's
drain,
water, and electrical
connections.
2.
All utilities
must be routed in shaded area in the
Figure
2.
IMPORTANT:
Disconnect
power
before
starting
installation.
Note: Locate the electrical
supply and dishwasher's
electrical
junction
box on right underside of unit behind kickplate
assembly.
See Figure
4. Determine where you will connect
to hot water supply.
Review
Figure
4 and note the location of
water inlet valve. Determine where you will connect the drain
hose.
3.
Cut access
holes for the Electrical,
Water and Drain hoses in the
shaded areas as shown in Figure
2.
4.
The dishwasher
operates on a 120 volt, 60 Hz electrical
supply.
Provide a separate
circuit with a fuse or circuit breaker rated for
at least 15 amps (20 amps if connected
with disposer)
but not
more than 20 amps.
5.
Pull electrical
cable through hole into installation area.
6.
Be sure water inlet valve is protected from freezing.
Ifvalve
freezes and ruptures, flooding may occur.
7.
Determine amount of tubing needed to connect hot water supply
to the unit's water inlet valve.
Extra hose length
is necessary.
High-pressure
and high-temperature
Stainless Flexible hose with
a minimum
inner diameter of V4"may be used. A shut-off valve
installed outside
dishwasher
cabinet is best.
8.
Route water supply line into installation
area.
9.
Stand dishwasher
back upright for further installation.
IMPORTANT:
Incoming
hot water
temperature
should
be at
least
120°F (49°C).
Water
pressure
should
be between
20-90
psi.
Water Line
Brass Elbow
Electrical Line
(Not Included)
(Not Included)
Figure
4
Property Damage
Do not use the
furnished
drain hose or a rubber garden hose
for
the water supply line. Either of these hoses can burst.
Flooding
may occur and cause property damage.
'::::::
DrainH0seC0nnect
Or
2
k
EndStorageLocation
NOTE:
Pull the hose from "End Storage Location"
side.
See images below to connect the Drain Hose.
L
Take drain Hose out of dishwasher and find the end that
doesn't have the black rubber material.
2.
Use only the spring clamp that is provided in the accessory
kit, place spring clamp over one of the hoses. See Image
Below.
Hose Attached
To Dishwasher
Remove
Plastic
End
Plug
Of Hose
Clamp
Hose Shipped
Inside Dishwasher
3.
Take the plastic side of the drain hose and insert it into the
hose that is already attached to the dishwasher
make sure
hose ends are flush against each other.
See image
below.
4.
Secure the spring clamp 1/8" from large end of black hose to
the plastic side that was inserted for best sealing results.
See Image
Below.
Plastic
Ends
of
Hoses
Flush
Hose
Attached
to
Dishwasher
Tighten
Spring
Clamp
,
Measure height of cabinet opening from underside of countertop
to floor. Check chart for height opening and suggested
adjustment.
Leg Leveler Adjustment
Chart
Height of
Number of Turns to
Cabinet Opening
Adjust Levelers
34" (86.4cm)
0
34W' (86.7cm)
2
348h?' (87.2cm)
6
34Vf (87.6cm)
9
2.
Move dishwasher
to front of installation area.
3.
Loosen the rear leveling legs by turning counterclockwise.
Refer
to chart for number of turns.
Dishwasher
Anchoring
4.
Install the Cabinet
Seal Kit (Instructions
included in Kit)
5.
Choose one of the methods of attachment
below to secure unit,
holes need to be pre-drilled
using a #5 drill bit regardless
of
the option chosen:
a. Side Mount Cabinet Clips (Preferred
Method of attachment)
b. Top Mount Cabinet Clips (to be used when Side Mount
is not an available
option)
CAUTION:
Use extreme
care
in mounting
the dishwasher
as to not
scratch,
bump
or otherwise
damage
the console
or tub.
To install
the Side
Mounting
Clips.
Depending
on space allowed in cabinet the Side Mounting
Clips can be installed with the holes for the screw up (preferred
method) or down as shown in the illustrations
below.
(Use extreme
caution when the clips are in the down position while installing
the dishwasher).
NOTE: Install
Side
Mount
Brackets
before
unit is installed
into
the cabinet.
Insert
screws
into the front
holes of the
mounting
clips
only.
(See image
below)
Use
if
measures
34V8"
to
35"
screw
Use
if
measures
34" to 34V8"
screw
To
install
using Top Mount Cabinet Clips:
Depending on the depth of cabinet, the Top Mount
Clip have a break off point that can be removed
if
necessary.
NOTE:
Install
Top
Mount
Clips
before
unit is installed
into the
cabinet.
Screw
clips
firmly
to top brace using
screws
provided
in the literature
pack. (See
image
below)
/////////////////////
!I