Installation Instructions Remote Blower Assembly for Telescoping Downdraft Ventilation System (1600cfm) 316902918 (April 2012) - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 2
for domestic cooking ONLY. Thank you for choosing Electrolux, the new premium brand in home appliances. These Installation Instructions are part of our commitment to customer satisfaction and product quality throughout the service life of your new appliance. We view your purchase as the beginning - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 3
Instructions appearing in this guide are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when installing, maintaining or operating an appliance. ALWAYS contact your dealer, distributor, service Heating, Refrigeration and Air - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 4
and FH36DD50MSA only. Use of this blower assembly with any other product or in any other configuration is hazardous and voids the product warranty. NOTE • Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting. • Locate the cooking area for minimum - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 5
Remote Blower Shipping Pack 5 Mounting Hardware Instruction Manual - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 6
.2 cm) 4-3/4" (12.1 cm) Adjustable Discharge List of Included Parts for model EI16DDPRKS: • (1) Blower • (4) 1/4" Lag Bolts IMPORTANT Retain all packing and materials until the telescoping downdraft and all components have been installed. Hardware Needed (User Supplied) • 14 AWG Romex Cable (Min - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 7
installation of this appliance. Carefully check the location where the remote blower is to be installed Remote Blower can be installed in various locations. These Installation Instructions will cover some of with the lag bolts into solid structural support members. Local building codes must be - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 8
to the section drawings on the following pages to determine the proper mounting orientation for the Main Blower Housing. DO NOT install the unit so that the unit is supported by the Blower Cover. Damage to the Blower may occur. Blower Cover (16) Silver Hex Head Screws (3) Hex Head Screws Wire - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 9
unit to the main blower housing. DO NOT mount the main blower housing directly to sub-flooring or wall materials, this will not support the remote blower housing correctly. Before making any electrical connections, verify that the blower wheel spins freely. Make the required electrical connections - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 10
10 Installation on Floor Joists Romex or Metal Conduit Floor Joists Inlet Metal Duct Discharge Duct Main Blower Housing Lag Bolts must be attached to joists, studs or structural members. 1/4" Lag Bolts (4) Conduit / Romex Inlet Flooring Floor Joist 1/4" Lag Bolts (4) Discharge - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 11
Ceiling Joist Installation on Ceiling Joists 11 1/4" Lag Bolts (4) Discharge Conduit / Romex Inlet Ceiling - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 12
12 Installation on Wall Studs Conduit / Romex Inlet Discharge 1/4" Lag Bolts (4) Wall Wall Stud - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 13
Zinc Plated Phillips Screws Wall Stud Discharge 4 3/4" x 14" 1/4" Lag Bolts (4) Sealant Note: Minimum 18" from the ground. Refer to Outdoor Weather Kit Installation Instructions for specific installation details. 3-1/4" Duct 4" Duct 4-3/4" Duct Bottom Mouting Hole Vent Slide Hex Head Screws - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 14
14 Electrical Connections Before making any electrical connections, verify that the blower wheel spins freely. Make the required electrical connections according to the wiring diagram. Remote Blower Electrical Connection Loosen the 3 terminal block screws. Insert the leads from the Romex cable - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 15
the power supply at the circuit breaker. 3. Refer to the Telescoping Down Draft Installation Instructions for additional instructions on proper operation. DO NOT allow any objects to contact any moving parts or electrical connections while verifying blower operation. Replace the Cover Re-attach the - Electrolux EI16DDPRKS | Installation Instructions (English, Spanish, French) - Page 16
warranted by Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this
Installation Instructions
Remote Blower Assembly for Telescoping Downdraft Ventilation System
(1600cfm)
316902918 (April 2012)