SERVICE DATA SHEET
A17002106
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R600a
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
This concludes the hardware tests. The following tests correspond to firmware versions. Before each firmware version is displayed “--” will appear on screen
followed by each 8-digit string representing firmware version. After the string has been displayed, “--” will appear again before automatically proceeded to
the next 8-digit string. Press “+” to advance to the next string at any time
--
Software Version
Runs automatically scrolling through all digits
Press “+” button to skip to next test
Displays digit sequence related to software
loaded onto main power board; 8 digit sequence
Software version is able to be
recorded from display
--
Main Board
Firmware Version
Runs automatically scrolling through all digits
Press “+” button to skip to next test
Displays digit sequence related to firmware
loaded onto main power board; 8 digit sequence
Firmware version is able to be
recorded from display
--
In-Door UI
Firmware Version
Runs automatically scrolling through all digits
Press “+” button to skip to next test
Displays digit sequence related to firmware
loaded onto Jade UI (inside door UI); 8 digit
sequence
Firmware version is able to be
recorded from display
--
VCZ UI
Firmware Version
Runs automatically scrolling through all digits
Press “+” button to skip to next test
Displays digit sequence related to firmware
loaded onto Indigo UI (VCZ UI); 8 digit sequence
Firmware version is able to be
recorded from display
--
Dispenser UI
Firmware Version
Runs automatically scrolling through all digits
Press “+” button to skip to next test
Displays digit sequence related to firmware
loaded onto external 4 button dispenser UI; 8
digit sequence
Firmware version is able to be
recorded from display
--
Lifetime
Press + button to advance to next digit
Displays number of days the appliance has been
powered up, even not consecutively
Range is from 0-9999
Lifetime displays successfully
on display
After Lifetime is displayed, last display is a 1-second counting up timer (0, 1, 2, 3…) this communicates that Service Mode has come to an end
To return to normal operation, press and hold “+” and “-” for 10 seconds or plug/unplug the appliance
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING
Type A with Run / Start Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
70 to 90%
90 to 100%
Freezer Temp
-6° to 6°F (-21° to -14°C)
-6° to 6°F (-21° to -14°C)
Refrigerator Temp
34° to 44°F (1° to 7°C)
34° to 44°F (1° to 7°C)
VCZ Temperature
-6° to 45°F (-21° to 7°C)
-6° to 45°F (-21° to 7°C)
Low Side Pressure
-1 to 3 psig (98 to 124 kPa)
.8 to 3 psig (107 to 120 kPa)
High Side Pressure (last 1/3 cycle)
69 to 83 psig (577 to 672 kPa)
117 to 128 psig (907 to 982 kPa)
Wattage (last 1/3 cycle)
45 to 55
54 to 74
Amps (running)
.7 to .9
.8 to 1.1
Base Voltage
115 vac
(127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size:
22’ CD
Thermal Cutout
Heater
Defrost Thermistor
Termination
Cut-out
Watts
Ohms
Cut-out
FRZ
162°F
(72.2°C)
220 +/- 5
51.3 +/- 5
48°F (8°C)
FF
38°F (3°C)
FFIM
70 +/- 5
189 +/- 5
61°F (16°C)
Electronic Timer - (ADC) Defrost 34 minutes every 12-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
.75
1.25
1100 ± 100
40 L/S
.104 A Max (@12V
DC/20°C)
Nominal Input Power (W) @ 80% Duty
Max Input Power (W)
Speed (R/Min) *@80% Duty @ 100%
Air Flow in Free Air (0 Pa)
ERROR CODES
Display
Interpretation
1st message
2nd message
Er
t1
FZR Temp Sensor Open/Shorted
Er
t2
FZR Defrost Sensor Open/Shorted
Er
t3
FF Temp Sensor Open/Shorted
Er
t4
FF Defrost Sensor Open/Shorted
Er
t5
VCZ Temp Sensor Open/Shorted
Er
t6
FFIM Tray Sensor Open/Shorted
Er
CE
Communication Error UI to Main Board
No message - Dispenser UI will beep
and blink either Cube or Crush (which-
ever is selected at the time of the error)
Chute Flapper Not Closed
SPECIAL MODES
Mode
Display
Activate
Deactivate
Manual Defrost
dF
Hold
+
and
Air Filter
for 10 secs
---
Cube Size Menu
Setting will appear
on UI
Hold
Freeze Boost
and
Ice Maker
for 10 secs
After 10 secs of no activity
Demo /
Showroom
Demo Light On
Hold
-
and
Water Filter
for 10 secs
Hold - and Water Filter for 10 secs
Sabbath
Sb
Hold
-
and
Temp F-C
for 5 secs
Hold - and Temp F-C for 5 secs
Service
---
Hold
-
and
+
for 10 secs
Hold
-
and
+
for 10 secs, or after 10 mins of inactivity
°
F/
°
C Display
Look at UI
Press
Temp F-C
to alternate between °F and °C
---
Notes:
Always check for pin backouts, pinched or damaged wires before replacing components. Determine whether failure is caused by the compo-
nent, main control board or wiring.
Contact TID before replacing main control board.
Refer to Service Manual for additional information.
SYSTEM DIAGNOSTIC MODE
Activate:
Press and hold + and - buttons for 10 secs.
Navigate through tests with +/- buttons
Deactivate:
Press and hold + and - buttons for 10 secs.
Display
Test
Activation/Deactivation
Display
Passing result
--
First Screen
--
Turn on all LEDS on main UI, VCZ UI, and external dispenser UI
---
--
Second Screen
--
Turn off all LEDS on main UI, VCZ UI, and external dispenser UI
---
2
FZR Defrost Heater
Press FREEZE BOOST to change status of load
Heater on when display reads “on”, off when “oF”
FRZ Evap Defrost sensor temp is flashed on display, watch for increase in temperature. May
take up to max 5 min for evap to warm up or 45°C sensor threshold
Defrost heater shows temp increase before 5 min have passed or
reaches 45°C cutout
8
Main Water Valve
Press FREEZE BOOST to change status of load
Main valve is activated when “on”, stops when “oF”
Valve is able to turn on and off
11
Cube/Crush Solenoid
Press FREEZE BOOST to change status of load
Solenoid activated when “on”, deactivated when “oF”
DO NOT LEAVE SOLENOID ACTIVATED FOR MORE THAN 1 MINUTE
Solenoid is able to turn on and off
53
Water Valve Dispenser + Main
Valve
Press FREEZE BOOST to change status of load
Water dispenses when “on”; stops when “oF”
Be prepared to collect water at dispenser
Water is dispensed successfully at dispenser
56
IM Water Valve + Main Valve
Press FREEZE BOOST to change status of load
Remove ice tray to collect water into a container to measure water fill
If collecting water into ice tray, perform test 50 first to empty tray.
Water flows in the tray when “on”, test is correspondent to Ice tray water fill setting;
automatically goes to “oF” state once configured time has elapsed
Water is dispensed at ice tray for configured time setting
71
FF Defrost Heater
Press FREEZE BOOST to change status of load
Heater on when display reads “on”, off when “oF”
FF Evap Defrost sensor temp is flashed on display, watch for increase in temperature. May
take up to max 5 min for evap to warm up or 45°C sensor threshold
Defrost heater shows temp increase before 5 min have passed or
reaches 45°C cutout
72
FFIM Defrost Heater +
Fill Tube Heater
Press FREEZE BOOST to change status of load
Heater on when display reads “on”, off when “oF”
FFIM Evap Defrost sensor temp is flashed on display, watch for increase in temperature. May
take up to max 5 min for evap to warm up or 45°C sensor threshold
Defrost heater shows temp increase before 5 min have passed or
reaches 45°C cutout
74
VCZ Balance Heater
Press FREEZE BOOST to change status of load
Heater on when “on”, off when “oF”; Maximum of 5 minutes on continuous
Defrost heater is successfully turned on and off; temperature increase is
noted in VCZ compartment
91
FRZ IM Fill Tube Heater
Press FREEZE BOOST to change status of load
Heater on when “on”, off when “oF”; Maximum of 5 minutes on continuous
Defrost heater is successfully turned on and off; temperature increase is
noted in fill tube area
10
Auger Motor
Press FREEZE BOOST to change status of load
FF DOOR MUST BE CLOSED
Motor running when “on”, motor stopped when “oF”
Auger motor is successfully activated
13
FF Light
Press FREEZE BOOST to change status of load
Fresh Food lights come on when “on”, lights turn off when “oF”
All FF lights come on
14
VCZ Light
Press FREEZE BOOST to change status of load
VCZ light come on when “on”, light turn off when “oF”
VCZ light turns on
15
FRZ Evaporator Fan Motor
Press FREEZE BOOST to change status of load
Fan runs at 3 speeds; Max speed “on”, medium speed “Mi”, stopped “oF”
Locked rotor will show “Lc”
No PWM signal will show “Ns” when fan is stopped (“oF”)
No 12V signal or ground will show “Np” when fan is “on” or “Mi”
Fan will cycle through all 3 speeds and “Lc” or “Ns” or “Np” is not displayed
17
VCZ Fan Motor
Press FREEZE BOOST to change status of load
Fan runs at 3 speeds; Max speed “on”, medium speed “Mi”, stopped “oF”
Fan will cycle through all 3 speeds successfully
18
Condenser Fan
Press FREEZE BOOST to change status of load
Fan runs at 3 speeds; Max speed “on”, medium speed “Mi”, stopped “oF”
Locked rotor will show “LC”
No PWM signal will show “nS” when fan is stopped (“oF”)
No 12V signal or ground will show “nP” when fan is “on” or “Mi”
Fan will cycle through all 3 speeds and “LC” or “nS” or “nP” is not displayed
20
FRZ Light
Press FREEZE BOOST to change status of load
FRZ light comes on when “on”, light turns off when “oF”
FRZ light turns on
38
VCC Compressor
Press FREEZE BOOST to change status of load
Compressor is running at max speed when “on”, stopped when “oF”
Compressor successfully turns on
47
Ice Chute Heater
Press FREEZE BOOST to change status of load
Chute heater is activated when “on”, deactivated when “oF”
Heater turns on successfully and difference in temperature is felt around
dispenser ice chute
62
FFIM Evap Fan Motor
Press FREEZE BOOST to change status of load
Evap fan motor is activated when “on”, deactivated when “oF”
Fan turns on successfully
63
Flipper Mullion DC Heater
Press FREEZE BOOST to change status of load
Flipper mullion heater is activated when “on”, deactivated when “oF”
Heater turns on successfully and difference in temperature is felt around
along flipper mullion
66
Dispenser Light
Press FREEZE BOOST to change status of load
Dispenser pocket light turns on when “on”, light turns off when “oF”
Dispenser pocket light turns on successfully
70
FF Evap Fan Motor
Press FREEZE BOOST to change status of load
Fan runs at 3 speeds; Max speed “on”, medium speed “Mi”, stopped “oF”
Locked rotor will show “LC”
No PWM signal will show “nS” when fan is stopped (“oF”)
No 12V signal or ground will show “nP” when fan is “on” or “Mi”
Fan will cycle through all 3 speeds and “LC” or “nS” or “nP” is not displayed
76
VCZ Damper Heater
Press FREEZE BOOST to change status of load
VCZ damper heater activated when “on”, deactivated when “oF”
Heater turns on successfully and difference in temperature is felt around
along VCZ damper
77
VCZ Damper Motor
Press FREEZE BOOST to change status of load
FRZ EVAP FAN WILL TURN ON AT MAX SPEED
Damper is open when “OP”, closed when “CL”
Check for airflow when damper is fully open (“OP”) and no air flow when fully closed (“CL”)
Screen will blink “1” during damper movement
Any FRZ evap fan motor errors will display alternatively of damper status during test
Damper opens and closes successfully and no air flow is felt when
damper is in closed (“CL”) position
36
Ice Chute Door/Flapper Motor
Press FREEZE BOOST to change status of load
When flapper is closed, shows “CL”, when open “OP”
During movement of flapper, screen will blink “1”
Flapper will open/close for 3 cycles and will show “Er” if any failues are detected
Flapper door opens and closes successfully, “Er” does not show on display
50
FFIM Twist Tray Harvest Test
Press FREEZE BOOST to change status of load
REMOVE ICE BUCKET IN ORDER TO SEE ROTATION OF TRAY
Display will show “Go” when tray is in home position (horizontal)
During rotation, screen will blink “1”
In case of failure at end of twisting operation, will show “Er”
Tray twists successfully and “Er” is not displayed at the end of the cycle
78
FFIM Bail Arm/Ice Level Bucket
Press FREEZE BOOST to change status of load
REMOVE ICE BUCKET IN ORDER TO SEE STATUS OF IM BAIL ARM
Allow bail arm to drop freely, “Em” (empty) will show when tray returns home
Hold bail arm up by hand, “Fu” (full) will show when tray returns home
In case of failure at end of twisting operation, will show “Er”; Screen will blink “1” during rotation
Bail arm successfully completes test and “Er” is not displayed at the end
of each cycle
61
Stepper Motor Valve
Press FREEZE BOOST to change status of load
COMPRESSOR WILL AUTOMATICALLY RUN AT MAX SPEED
Valve can cycle through 4 states:
1. “03” - Open position
2. “00” - Close position
3. “01” - IM/FZ position
4. “02” - FF/IM/FZ position
FFIM Evap temp is flashed during 00 and 01 to check if temp is increasing/decreasing in FFIM evap
FF Evap temp is flashed during steps 03 and 02 to see if temp is increasing/decreasing in FF evap
During movement
Valve successfully cycles through all 4 positions; evap temps are increas-
ing/decreasing as described
23
FF Door
Open/Close FF Door
Display shows “CL” when door is closed, “OP” when open
Display reads correctly when door is opened/closed
24
FRZ Door
Open/Close FRZ Door
Display shows “CL” when door is closed, “OP” when open
Display reads correctly when door is opened/closed
25
VCZ Door
Open/Close VCZ Door
Display shows “CL” when door is closed, “OP” when open
Display reads correctly when door is opened/closed
28
Dispenser Paddle
Press paddle
Display shows “oF” when paddle is not pressed or released; shows “on” when paddle is pressed
Display shows “oF” when paddle is not pressed and “on” when paddle
is pressed
29
FF Temp Sensor
Activates automatically
Display will show compartment temperature in either °C or °F depending on mode
Display will read “OP” if open circuit, “SH” if short circuit
Temperature is displayed and does not show “OP” or “SH”
30
FRZ Temp Sensor
Activates automatically
Display will show compartment temperature in either °C or °F depending on mode
Display will read “OP” if open circuit, “SH” if short circuit
Temperature is displayed and does not show “OP” or “SH”
31
FF Evaporator Temp Sensor
Activates automatically
Display will show FF evaporator temperature in either °C or °F depending on mode
Display will read “OP” if open circuit, “SH” if short circuit
Temperature is displayed and does not show “OP” or “SH”
32
VCZ Temp Sensor
Activates automatically
Display will show compartment temperature in either °C or °F depending on mode
Display will read “OP” if open circuit, “SH” if short circuit
Temperature is displayed and does not show “OP” or “SH”
33
Ambient Temp Sensor
Activates automatically
Display will show ambient temperature in either °C or °F depending on mode
Display will read “OP” if open circuit, “SH” if short circuit
Temperature is displayed and does not show “OP” or “SH”
39
FRZ Evaporator Temp Sensor
Activates automatically
Display will show FRZ evaporator temperature in either °C or °F depending on mode
Display will read “OP” if open circuit, “SH” if short circuit
Temperature is displayed and does not show “OP” or “SH”
45
FFIM Tray Temp Sensor
Activates automatically
Display will show FFIM tray temperature in either °C or °F depending on mode
Display will read “OP” if open circuit, “SH” if short circuit
Temperature is displayed and does not show “OP” or “SH”
68
FFIM Evaporator Temp Sensor
Activates automatically
Display will show FFIM evaporator temperature in either °C or °F depending on mode
Display will read “OP” if open circuit, “SH” if short circuit
Temperature is displayed and does not show “OP” or “SH”
64
Humidity Sensor
Activates automatically
Display will show relative humidity sensed by H&T sensor in %
Display will read “OP” if open circuit, “SH” if short circuit
Humidity is displayed and does not show “OP” or “SH”