SERVICE DATA SHEET
A01544501
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
POWER
ICE MAKER
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
THERMAL
CUT-OUT
HOLD
SWITCH
THERMOSTAT
SHUTOFF
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUNTING
PLATE
165 WATTS
MOTOR
NEUTRAL
BLK
BLK
BLK
BLU
C
C
C
NO
NO
NO
NC
NC
NC
YELLOW
BRN
RED
GRN / YEL
RED
RED
LT. BLUE
P-3
P-1
P-2
P-4
ICE MAKER
LT. BLUE
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position and
properly secured.
SYSTEM DIAGNOSTIC MODE
Activate:
Press
FZ
UP
and
FZ
DOWN
for up to 10 sec. simultaneously. Press
FF
UP
to advance through tests.
Deactivate:
Press
FF
UP
for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
Passing result
--
First Screen
--
Blank UI display, no lights illuminated.
--
Second Screen
--
All LED lights on UI illuminated.
--
Third Screen
--
Blank UI display, no lights illuminated.
2
Defrost Heater
Press power on-off
Defrost heater on when “on”; off when “off”.
3*
FF Light
(Incandescent Models)
Press power on-off
FF lights on when “on”; off when “off”
9*
FZ Light
Press power on-off
With FZ door open, FZ lights on when “on”, off when “off”
12
VCC Condenser Fan
Press power on-off
Fan running when “on”; stopped when “off”
41*
Perfect Temp
Drawer (PTD)
Press power on-off
PTD UI illuminated when “on”; off when “off”
13*
FF Light (LED Models)
Press power on-off
FF lights on when “on”; off when “off”
38
VCC Compressor
Press power on-off
Compressor running when “on”; stopped when “off”
15
Evaporator Fan
Press power on-off
Stopped when “off”. Listen for speed change from “LO” to “HI”.
20*
FZ Light (LED Models)
Press power on-off
FZ lights on when “on”, off when “off”
22
Damper
Press power on-off
With inspection mirror, observe damper open when “OP”; closed when “CL”
23
FF Door
Open/close FF door
“CL” on UI when door closed; “OP” when open
24
FZ Door
Open/close FZ door
“CL” on UI when door closed; “OP” when open
29
FF Thermistor
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at FF thermistor location.
“OP” if open; “SH” if short
30
FZ Thermistor
Activates automatically
UI shows temperature sensed by FZ thermistor; pass if within 10°F of
temperature measured with gauge at FZ thermistor location.
“OP” if open; “SH” if short
33
Ambient Thermistor
@ Main Board
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/-10°F
of temperature measured with gauge at main board location.
“OP” if open; “SH” if short
39
Evaporator
Thermistor
Activates automatically
UI shows temperature sensed by evaporator thermistor; pass if within
10°F of temperature measured with gauge at evaporator thermistor
location. “OP” if open; “SH” if short
34*
Ambient Thermistor
@ UI
Activates automatically
UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem-
perature measured with gauge at UI location. “OP” if open; “SH” if short
0-
Firmware
Parameters
Press power on-off
Displays digit sequence; record
2-
Main Board
Firmware
Press power on-off
Displays digit sequence; record
4-
UI Firmware
Press power on-off
Displays digit sequence; record
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
Replace Inverter Board
Check at Inverter Board on
Compressor
(BLK and RED wires)
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
Check at Main Control Board
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
no
Check at the connector from the power cord
harness into the inverter board, located in
the machine
compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
Check voltage supply.
Check and repair power
cord harness wiring and
connections.
no
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
yes
Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
shown.
Is resistance across all winding
pairs equal?
Replace Compressor and
Inverter Board.
no
Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
yes
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
no
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Replace Main Control Board.
no
yes
yes
yes
ERROR CODES
SPECIAL MODES
Display
Interpretation
Mode
Display
Activate/Deactivate
(press for up to 10 sec. simultaneously)
FZ
FF
FZ
FF
--
OP
Open FF Thermistor
Manual Defrost
d
F
FF
UP
and FF DOWN / same to deactivate
OP
--
Open FZ Thermistor
Display / Showroom
77
77
FZ UP and FF DOWN /
Power-on-Reset (POR)
--
SH
Shorted FF Thermistor
Sabbath
Sb
Sb
FZ DOWN and
FF
UP
/ same to deactivate
SH
--
Shorted FZ Thermistor
System Diagnostic
No FF or FZ
display, all UI
LEDs on.
FZ UP and FZ DOWN /
FF
UP
to deactivate
SY
CF
UI to Main Control Board
communication failure;
on start up
Notes:
• Always check for pin back-outs, pinched or damaged wires before
replacing components.
• Determine whether failure is caused by the component, main control board or wir-
ing.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
SY
CE
UI to Main Control
Board
communication error;
after a period in operation
SY
EF
Evaporator Fan Failure
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
90 to 100%
100%
Freezer Temperature
-5° to 2°F
(-20° to -17°C)
-1° to 3°F
(-18° to -16°C)
Refrigerator Temperature
34° to 39°F
(1° to 4°C)
34° to 39°F
(1° to 4°C)
Low Side Pressure
-2 to 6 psig
(-14 to 41 kPa)
-2 to 6 psig
(-14 to 41 kPa)
High Side Pressure
(last 1/3 cycle)
85 to 105 psig
(586 to 724 kPa)
120 to 135 psig
(827 to 931 kPa)
Wattage (last 1/3 cycle)
30 to 50
50 to 70
Amps (running)
.4 to .8
.7 to .9
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size:
27’ & 28’ SD, 22’ CD
Thermal Cutout
Heater
Defrost
Heater
Termination
Cut-in
Cut-out
Watts
Ohms
Cut-out
110°F
(43.3°C)
135°F
(57.2°C)
500
26.5
39°F
(4°C)
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage
115 vac
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation;
it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling:
Remove cover by inserting screwdriver in notch at
bottom and prying cover from housing. Use
screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of
ice maker should function to complete the cycle.
Water Fill Volume:
The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.).
The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked.