    EPSON PRODUCT SUPPORT BULLETIN Date: 8/30/2007 Originator: DS PSB #: PSB.2007.08.001 Authorization: Reference: N/A Total Pages: 1 Product(s): Epson Projectors with an HD-15 VGA Analog/Component Input Subject: Elmo HV-110XG Document Camera and Projector to an Epson projector. Problem: When
  • 1

Page 1 of 1
EPSON
P
RODUCT
S
UPPORT
B
ULLETIN
Date:
8/30/2007
Originator:
DS
PSB #:
PSB.2007.08.001
Authorization:
Reference:
N/A
Total Pages:
1
Product(s):
Epson Projectors with an HD-15 VGA Analog/Component Input
Subject:
Elmo HV-110XG Document Camera and Projector Compatibility
This bulletin was created to inform you of an operational issue with the Elmo HV-110XG
Document Camera when initially connected to an Epson projector.
Problem:
When attempting to use the Elmo HV-110XG Document Camera connected via the VGA HD15
connection to display content from its document bed.
When connected to the projector, the
projector displays only the
Blue Screen - No Signal
message and will blink off and on or
display just the Blue Screen - No Signal message.
When a computer is connected to the Elmo
HV-110XG Document Camera and switched to Pass-Through mode, the computer image is
displayed correctly by the projector.
When switching back to the document table source of the
Elmo HV-110XG Document Camera, the problem returns. The Elmo HV-110XG Document
Camera puts out a Progressive Scan 20fps signal to the projector's VGA Analog port.
This
signal is detected at 15 kHz Vertical and 291.8 kHz Horizontal frequencies which are beyond
projector sync specifications.
Solution:
With the Elmo HV-110XG Document Camera powered on and connected to the projector via
the VGA computer cable, access the
Computer1/Computer2
setting in the projector menu
system and select the
Component
setting within the appropriate connection. This will allow
the Elmo HV-110XG Document Camera and projector to sync and the projector to display the
image of the document camera bed and its contents.
However, the image will have a pink
cast.
To eliminate the pink cast, change the projector setting from Component to
RGB
then to
Auto
and exit from the menu
.
The projected image will now look normal.
This will now allow
the Elmo HV-110XG Document Camera to sync and display the image properly to any other
connected Epson projector without having to change the projector settings.