Fisher and Paykel DD24DCTW9 N Installation Guide

Fisher and Paykel DD24DCTW9 N Manual

Fisher and Paykel DD24DCTW9 N manual content summary:

  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 1
    DOUBLE DISHDRAWER™ DISHWASHER DD24DA & DD24DCT models INSTALLATION GUIDE US CA 591153C 05.19
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 2
    be installed to allow for future removal from the enclosure if service is required. O The switched power outlet must be outside the could result in injury or cuts. IMPORTANT! SAVE THESE INSTRUCTIONS The models shown in this installation guide may not be available in all markets and are subject
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 3
    2 PARTS SUPPLIED Drain hose support (1) Drain hose joiner (1) Wire clip (2) (for securing Drain hose joiner) Clamp to be used as a guide on how to install a DishDrawer™ yourself. https://vimeo.com/325297597 If the Drain hoses supplied are not long enough to reach your services, you must use a
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 4
    3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-A REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 3-B REMOVE THE ACCESS COVER & REMOVE POWER CORD 3 3 1 2 4" (
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 5
    3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-C TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS 12 8 9 13 14 11 IMPORTANT! Ensure the mains wires are routed UNDERNEATH all other harness 10 wiring from the electronics module. 8 Fit a suitable cable clamp for the conduit
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 6
    H K I J G FRONT B D E O PLAN 5 4 PRODUCT DIMENSIONS C A F L M PROFILE N DD24DA PRODUCT DIMENSIONS INCHES (MM) A Overall height of product1 32 5/16 - 34 5/8" (820-880)2 B Overall width of product 23 9/16" (599) C Overall depth of product 22 9/16" (573) D Depth of chassis (to back
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 7
    5 CABINETRY DIMENSIONS Q R Bracket slots CABINETRY DIMENSIONS P Inside height of cavity* Q Inside width of cavity R Inside depth of cavity S Recommended height of adjacent cabinet space T Height of toekick space* * depending on adjustment of leveling feet PLAN DD24DA INCHES (MM) min. 32 5/16"
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 8
    450 mm) Max 1/4" (5mm) Max distance between hole edge and rear inner face Hoses Power cord Max 1/2" (10mm) Max distance between hole edge and floor Service Holes Can be located either side of dishwasher, close to the rear face and the floor, as illustrated, for access to the water supply, drain
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 9
    7 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE Drain hoses - 78 1/2" (2000 mm) Inlet hose - 64 3/4" (1650 mm) Power cord (excl.plug) - 29 1/2" (750 mm) RIGHT HAND SIDE Drain hoses - 70 1/2" (1800 mm) Inlet hose - 49" (1250 mm) Power cord (excl.plug) - 27 1/2" (700 mm) 8
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 10
    NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 8 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 9-A ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed B screwdriver.
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 11
    !1-A SECURE TO THE CABINETRY ON THE SIDES 1 Open the drawer halfway. Using a flat bladed screwdriver, prise the gray rubber plug out of the trim moulding. 2 Replace the gray rubber plug back into the trim moulding and ensure the trim seal is facing forward. 3 !2-A OPTIONALLY SECURE TO THE
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 12
    8 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL 9-B PULL THROUGH HOSES & PUSH INTO THE CAVITY optionally attach the two top mounting brackets (x2) Initially level the product You can raise or lower the product by twisting the feet. Then take care when pushing the product into the cavity that
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 13
    !1-B SECURE TO THE CABINETRY ON THE SIDES For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend leveling feet up to required distance by hand. !2-B OPTIONALLY SECURE TO THE CABINETRY ABOVE (x2) The top mounting brackets will only bend upwards a maximum
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 14
    !4-B FIT THE SUPPLIED TOEKICK PANEL Where the toekick meets the bottom 3 of the tub is the cut-off point 1 Lay the toekick face down on a chopping board or similiar 2 Mark this point on the toekick with a pencil 4 19 Score along the marked cutoff line with a knife 5 19 Turn the toekick over
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 15
    to back wall at correct height. If space is limited for fixing, push hose through drain hose support 2 to required height. max. 4 3/4" (120 mm) 29 1/2"-34 3/4" (750-883 mm) 1 Ø1 1/2" (38 mm) step 16 min. R 8" (200 mm) min. 19 11/16" (500 mm) 29 1/2 -
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 16
    commercially available Dual (Double) Air Gap/Break Kit. This provides totally separate draining for each drawer and eliminates possible "cross draining" problems Drain hose Drain hose 2 Secure both drain hoses to a Dual Air Gap/Break IMPORTANT! Ensure that drain connection will comply with local
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 17
    to back wall at correct height. If space is limited for fixing, push hose through drain hose support 2 to required height. 29 1/2"-34 3/4" (750-883 mm) Supplied drain hose joiner to suit Ø 3/4" (19 mm) waste tee 3 1 min. 19 11/16" (500 mm) 29 1/2 -
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 18
    section 'If there is a fault' in the User guide for further information and instructions. O No program indicator lights up when the drawer problem occurs, consult the 'Troubleshooting' section of the User guide. O If after checking these points you still need assistance, please refer to the Service
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 19
    and drain connection has been made. The drain hose joiner must not support the weight of excess hose material. Keep drain hose as fully extended the water hardness of the area. See the Quick start guide and section 'Water softener' in the User guide. Turn on the power and water supplies, then open
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 20
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 21
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 22
    SINGLE DISHDRAWER™ DISHWASHER DD24SA & DD24SCT models INSTALLATION GUIDE US CA 591153C 05.19
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 23
    be installed to allow for future removal from the enclosure if service is required. O The switched power outlet must be outside the could result in injury or cuts. IMPORTANT! SAVE THESE INSTRUCTIONS The models shown in this installation guide may not be available in all markets and are subject
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 24
    2 PARTS SUPPLIED Drain hose support (1) Drain hose joiner (1) Wire clip (1) (for securing Drain hose joiner) Clamp to be used as a guide on how to install a DishDrawer™ yourself. https://vimeo.com/325297597 If the Drain hoses supplied are not long enough to reach your services, you must use a
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 25
    3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-A REMOVE THE DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 1 3 4 Push drawer 2 runners back in on either side. Sit the drawer
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 26
    3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-C TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS 12 8 9 13 14 11 IMPORTANT! Ensure the mains wires are routed UNDERNEATH all other harness 10 wiring from the electronics module. 8 Fit a suitable cable clamp for the conduit
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 27
    F FRONT B E PLAN 5 4 PRODUCT DIMENSIONS C H A I G PROFILE PRODUCT DIMENSIONS A Overall height of product1 D B Overall width of product C Overall depth of product D Depth of chassis (to back of front drawer panel) E Depth of drawer front panel F Height of drawer front panel G Height of
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 28
    5 CABINETRY DIMENSIONS CABINETRY DIMENSIONS K Inside height of cavity L Inside width of cavity M Inside depth of cavity L K M Bracket slots PLAN DD24SA INCHES (MM) min. 16 1/4" (412) 23 5/8" (600) min. 22 1/16" (560) DD24SCT INCHES (MM) min. 18" (456) 23 5/8" (600) min. 22 1/16" (560)
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 29
    11/16" (450 mm) Max 1/4" (5 mm) Max distance between hole edge and rear inner face Max 1/2" (10 mm) Max distance between hole edge and shelf Service Holes Can be located either side of dishwasher, close to the rear face and the shelf, as illustrated. O If the hole is through wood, make
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 30
    7 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE Drain hose - 78 1/2" (2000 mm) Inlet hose - 64 3/4" (1650 mm) Power cord (excl.plug) - 78 1/2" (2000 mm) RIGHT HAND SIDE Drain hose - 70 1/2" (1800 mm) Inlet hose - 49" (1250 mm) Power cord (excl.plug) - 78 1/2" (2000 mm) 8
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 31
    NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 8 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 9-A B ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver.
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 32
    !1-A SECURE TO THE CABINETRY ON THE SIDES 1 Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. 2 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry. Do not damage the
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 33
    8 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL 9-B PULL THROUGH HOSES & PUSH INTO THE CAVITY As you push product in, pull through hoses and cord, ensuring they don't get kinked or twisted. IMPORTANT! If product cannot be pushed in far enough, pull out again and rearrange hoses and cord. Do not
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 34
    !1-B SECURE TO THE CABINETRY ON THE SIDES The product has three pairs of fixing points: Ensure the sound insulation is repositioned correctly. two pairs of formed brackets on either side of the chassis (use 5/8" (16mm) screws) 2 Before refitting the drawer, ensure the hoses are not twisted and
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 35
    to back wall at correct height. If space is limited for fixing, push hose through drain 2 hose support to required height. max. 4 3/4" (120mm) 29 1/2" - 34 3/4" (750 - 883 mm) min. 19 11/16" (500mm) 29 1/2 - 34 3/4" (750 - 883mm) 1 1 1/2" (38 mm) step 14 IMPORTANT! Ensure
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 36
    DRAINAGE OPTION 2 Dishwasher using Air Break with Drain Hose Joiner Secure drain hose to drain hose joiner and secure to Air Break 2 IMPORTANT! Ensure that drain connection will comply with local plumbing regulations. 1 step 14 min. R 8" (200mm) 37 3/8" (950mm) Max. height to top of Air Break (
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 37
    ) DRAINAGE OPTION 3 Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall at correct height. If space is limited for fixing, push hose through drain hose support 2 to required height. 1 step 14 Supplied drain hose joiner to suit Ø 3/4" (19 mm) waste tee
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 38
    !4 CONNECT INLET HOSE TO HOT WATER Ensure the supplied rubber washer is fitted inside the coupling. 1 180o No leaks! Tighten coupling with spanner. 2 !5 SWITCH PRODUCT ON 16
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 39
    section 'If there is a fault' in the User guide for further information and instructions. O No program indicator lights up when the drawer problem occurs, consult the 'Troubleshooting' section of the User guide. O If after checking these points you still need assistance, please refer to the Service
  • Fisher and Paykel DD24DCTW9 N | Installation Guide - Page 40
    and drain connection has been made. The drain hose joiner must not support the weight of excess hose material. Keep drain hose as fully extended the water hardness of the area. See the Quick start guide and section 'Water softener' in the User guide. Turn on the power and water supplies, then open
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14