Fluke 116 Fluke 116 Digital Multimeter Datasheet

Fluke 116 Manual

Fluke 116 manual content summary:

  • Fluke 116 | Fluke 116 Digital Multimeter Datasheet - Page 1
    Fluke 116 HVAC Multimeter with Temperature and Microamps Technical Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp
  • Fluke 116 | Fluke 116 Digital Multimeter Datasheet - Page 2
    % + 2 1.9 % + 2 5 % + 20 10 % + 2 typical 1 % + 102 1 % + 182 Ordering information Fluke-116 HVAC Multimeter with Temperature and Microamps Included TL75 Test Leads, 80BK Integrated Temperature Probe, holster, User's manual and 9V battery (installed). AC µamps true-rms (45 Hz to 500 Hz) 600
  • 1
  • 2

Technical Data
Fluke 116
HVAC Multimeter
with Temperature and Microamps
Features include:
Built in thermometer for HVAC applications
Microamps to test flame sensors
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
Resistance, continuity, frequency and capacitance
Min/Max/Average with elapsed time to record signal
fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak
)
CAT III 600 V safety rated
Compact true-rms meter for
HVAC troubleshooting
The Fluke 116 was specifically designed
for the HVAC professional. It has every-
thing needed in an HVAC meter including
temperature and microamp measure-
ments to quickly troubleshoot problems
with HVAC equipment and flame sensors.
General specifications
Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, with relative humidity at
0 % to 95 %.
The accuracy specifications take the form of:
± ( [ % of reading ] + [ counts ] )
Maximum voltage between any
terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 V
CAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4/sec
Bar graph
33 segments, updates 32/sec
Operating temperature
-10 °C to + 50 °C
Storage temperature
-40 °C to + 60 °C
Battery
9 volt Alkaline, NEDA 1604A/
IEC 6LR61
Battery life
400 hours typical, without backlight
N10140
R
Actual size