Fluke 1625 FE 1625 Users Manual - Page 30

Warning, Attention, No voltage permissable to sockets, Do not open or close the instrument with force

Page 30 highlights

1625 Users Manual D "CHANGE ITEM" button to change the set point entry values. E "SELECT" button to select the digit to be changed. F Display unit, liquid crystal digits, 18 mm high with automatic decimal point as well as active illumination. G Connecting socket H (auxiliary earth electrode) (4 mm ø) also usable with safety measuring lead H Connecting socket G (probe) (4 mm ø) also usable with safety measuring lead. I Connecting socket for an ext. clip-on current transformer (optional). W Warning No voltage permissable to sockets EFGH. J Connecting socket F (earthing probe) (4 mm ø) also usable with safety measuring lead. Potential pick off with 4-pole earthing measurement. K Connecting socket E (earth electrode) (4 mm ø) also usable with safety measuring lead. W Attention Do not open or close the instrument with force! L Battery compartment for: 6 x IEC LR6 batteries or type AA batteries. W Warning Disconnect all leads before opening the instrument! M Screws to fasten the battery compartment 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

1625
Users Manual
22
D
"CHANGE ITEM" button to change the set point entry values.
E
"SELECT" button to select the digit to be changed.
F
Display unit, liquid crystal digits, 18 mm high with automatic decimal
point as well as active illumination.
G
Connecting socket
H
(auxiliary earth electrode) (4 mm ø) also usable
with safety measuring lead
H
Connecting socket
G
(probe) (4 mm ø) also usable with safety measuring
lead.
I
Connecting socket for an ext. clip-on current transformer (optional).
W
Warning
No voltage permissable to sockets
EFGH
.
J
Connecting socket
F
(earthing probe) (4 mm ø) also usable with safety
measuring lead. Potential pick off with 4-pole earthing measurement.
K
Connecting socket
E
(earth electrode) (4 mm ø) also usable with safety
measuring lead.
W
Attention
Do not open or close the instrument with force!
L
Battery compartment for: 6 x IEC LR6 batteries or type AA batteries.
W
Warning
Disconnect all leads before opening the instrument!
M
Screws to fasten the battery compartment