    700G Series Pressure Gauge Users Manual November 2011 Rev. 1, 10/13 © 2011-2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Fluke 700GA6 | Product Manual - Page 2
    center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY
  • Fluke 700GA6 | Product Manual - Page 3
    Table of Contents Title Page Introduction ...1 How to Contact Fluke ...1 Standard Equipment...2 Safety Information ...2 Hazard Location Information/Approvals 3 Special Conditions for Safe Use 3 Symbols...4 Display and Buttons ...5 Operation ...7 How to Setup the Product 7 Engineering Units 7
  • Fluke 700GA6 | Product Manual - Page 4
    700G Series Users Manual Set Sample Rate 8 Set Tare ...8 Function Lock...8 Supervisory Mode ...8 Available Pressure Ranges 9 How to Set a Custom Engineering Unit or Scale 9 Battery Life ...9 Maintenance ...10 How
  • Fluke 700GA6 | Product Manual - Page 5
    List of Tables Table Title Page 1. Symbols...4 2. Display and Buttons ...5 iii
  • Fluke 700GA6 | Product Manual - Page 6
    700G Series Users Manual iv
  • Fluke 700GA6 | Product Manual - Page 7
    List of Figures Figure Title Page 1. The Product...5 2. Change the Batteries...11 v
  • Fluke 700GA6 | Product Manual - Page 8
    700G Series Users Manual vi
  • Fluke 700GA6 | Product Manual - Page 9
    . How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1- com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 1
  • Fluke 700GA6 | Product Manual - Page 10
    700G Series Users Manual Standard Equipment The Product ships with: • Protective Cover • Three AA Batteries (installed) • NPT/metric Adapter Safety Information A Warning identifies conditions and procedures that are dangerous
  • Fluke 700GA6 | Product Manual - Page 11
    Hazard Location Information/Approvals Ex Hazardous Areas An Ex-hazardous area as used in this manual refers to an area made hazardous by the potential presence of flammable or explosive vapors. These areas are also referred to as hazardous locations, see
  • Fluke 700GA6 | Product Manual - Page 12
    are explained in Table 1. Symbol Meaning Table 1. Symbols Symbol Meaning  Risk of danger. Important information. See manual.  Conforms to European Union directives.  Hazardous voltage. Risk of electrical shock.  Pressure  Conforms to relevant Australian standards.    Conforms
  • Fluke 700GA6 | Product Manual - Page 13
    Display and Buttons The Display and Buttons are shown in Figure 1. The Buttons are explained in Table 2. Pressure Gauge Display and Buttons 2 3 700G31 10K PSIG PRESSURE GAUGE 4 10K PSI 1 700 BAR Figure 1. The Product gsn001.eps 5
  • Fluke 700GA6 | Product Manual - Page 14
    700G Series Users Manual Item Table 2. Display and Buttons Function  Push to turn the Product on. Push again to turn it off.  Zeros the display. In Configure Mode, push
  • Fluke 700GA6 | Product Manual - Page 15
    Table 2. Display and Buttons (cont.) Item Function  MIN MAX records minimum and maximum pressure values and saves them in memory. Push  to show maximum (MAX) indication. Push again to show minimum (MIN) indication. After 2 seconds, the gauge goes back to live operation. To clear the MIN MAX
  • Fluke 700GA6 | Product Manual - Page 16
    700G Series Users Manual Operation The subsequent sections tell you how to operate the See the Specifications section for a list of available 8 engineering units. See the Supervisory Mode section for instructions to set up custom units. Set Auto Off Auto Off can be set in 1-minute increments from
  • Fluke 700GA6 | Product Manual - Page 17
    Set Sample Rate This function finds how often pressure is sampled and the display is updated. Selections are 0.5, 1, 3, and 10 samples/second. Note that 10/second gives the fastest response time. Set Tare Use this function to set a constant offset value which is then subtracted from the measured
  • Fluke 700GA6 | Product Manual - Page 18
    700G Series Users Manual each parameter. To move to the next parameter, push . You can access, lock, or unlock these functions: • Zero function (enable/disable) • Set pressure units (enable/
  • Fluke 700GA6 | Product Manual - Page 19
    Maintenance How to Clean the Product Clean the Product with a soft cloth dampened with water or water and weak soap. Caution To prevent possible damage to the Product, do not use solvents or abrasive cleansers. Caution For safe operation and maintenance of the product: • Repair the Product before
  • Fluke 700GA6 | Product Manual - Page 20
    700G Series Users Manual Accessories RS-232 Interface The Product includes an RS-232 interface. Remove the Product holster and the input jack is on the back of the
  • Fluke 700GA6 | Product Manual - Page 21
    Pressure Gauge Specifications Specifications Available Input Ranges See Ranges and Resolution table for available ranges in psi plus equivalent ranges and resolution for all engineering units. Accuracy 700G Ranges Positive Pressure 0.05 % FS Positive Pressure (700G01, 700G02 0.1 % FS Vacuum 0.1 %
  • Fluke 700GA6 | Product Manual - Page 22
    700G Series Users Manual Media Compatibility 700G01, 700G02, 700G04, 700G05, 700RG05 any clean dry non-corrosive gas All other ranges, 15 psi to 1000 psi any liquids or gases
  • Fluke 700GA6 | Product Manual - Page 23
    Pressure Gauge Specifications Mechanical Specifications Dimensions 11.4 x 12.7 (cm), depth = 3.7 cm (4.5 x 5 (in), depth= 1.5 in) Pressure Connection in NPT Male Housing Cast ZNAL Display 5-1/2 Digits, 16.53 mm (0.65 in) high 20-Segment bar graph, 0 to 100 % Power Battery three size AA alkaline
  • Fluke 700GA6 | Product Manual - Page 24
    700G Series Users Manual Ranges and Resolution Model Number Pressure Range (psi) Vacuum Range (psi) Burst Pressure (psi) Proof Pressure (psi) Engineering Unit psi bar mbar kPa MPa kg/
  • Fluke 700GA6 | Product Manual - Page 25
    Pressure Gauge Specifications Model Number Pressure Range (psi) Vacuum Range (psi) Burst Pressure (psi) Proof Pressure (psi) Engineering Unit mH2O @ 4°C mH2O @ 20°C inH2O @ 4°C inH2O @ 20°C inH2O @ 60°F ftH2O @ 4°C ftH2O @ 20°C ftH2O @ 60°F ft Sea Water m Sea Water Torr 700G01 700G02 700G04 700G05
  • Fluke 700GA6 | Product Manual - Page 26
    700G Series Users Manual Model Number 700GA4 700GA5 700GA6 700GA27 700RG05 700RG06 700RG07 700RG08 700RG29 700RG30 700RG31 Pressure Range (psi) 15 PSIA 30 PSIA 100 PSIA 300 PSIA 30 100 500 1000 3000 5000 10000 Vacuum Range (
  • Fluke 700GA6 | Product Manual - Page 27
    Pressure Gauge Specifications Model Number Pressure Range (psi) Vacuum Range (psi) Burst Pressure (psi) Proof Pressure (psi) 700GA4 700GA5 700GA6 700GA27 700RG05 700RG06 700RG07 700RG08 700RG29 700RG30 700RG31 15 PSIA 30 PSIA 100 PSIA 300 PSIA 30 100 500 1000 3000 5000 10000 0 PSIA 0 PSIA 0
  • Fluke 700GA6 | Product Manual - Page 28
    700G Series Users Manual 20
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

November 2011 Rev. 1, 10/13
© 2011-2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
700G Series
Pressure Gauge
Users Manual