Fluke 985 Fluke 985 - Airborne Particle Counter - Manual
Fluke 985 Manual
View all Fluke 985 manuals
Add to My Manuals
Save this manual to your list of manuals |
Fluke 985 manual content summary:
- Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 1
985 Airborne Particle Counter Users Manual March 2012 © 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 2
Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 3
Table of Contents Title Page Introduction ...1 How to Contact Fluke ...1 Applications ...1 Safety Information ...2 Battery...3 Product Overview ...3 The Buttons ...5 Product Connections 6 Charge Base Connections 7 Operation ...8 Power On/Off...8 Product Test ...8 How to Purge the Product Sensor - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 4
985 Users Manual Sample Screen Menu 10 Buffered Data Menu 11 Setup Menus...11 Sample Setup Submenus 13 Alarm Setup Submenu 13 Data Display Setup Submenu 13 Setting the Method of Counting Data 14 Location Setup Submenu 14 Communication Setup Submenus 15 Communication Setup - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 5
List of Tables Table Title Page 1. Symbols...3 2. Product Components...5 3. Buttons ...5 4. Product Connections ...6 5. Charge Base Connections...7 6. Main Menu Icons ...9 7. Sample Options ...12 8. Sample Setup Submenus...13 9. Location Submenu Icons ...14 10. Communication Submenu Icons 15 - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 6
985 Users Manual iv - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 7
List of Figures Figure Title Page 1. Product Components...4 2. Product Connections ...6 3. Charge Base Connections...7 4. Sample Screen ...10 5. Exported Data ...20 v - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 8
985 Users Manual vi - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 9
your product, visit http://register.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Applications The Particle Counter can be used to: • Monitor cleanrooms • Investigate indoor air quality • Monitor gowning rooms • Test filter seals - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 10
985 Users Manual Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies disassemble this Product, it contains no user-serviceable parts. • Do not use, and disable the Product if it is damaged. • Use the Product only as specified or - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 11
be disposed of by a qualified recycler or hazardous materials handler per local regulations. Contact your authorized Fluke Service Center for recycling information. Airborne Particle Counter Battery Battery A rechargeable Lithium-ion battery powers the Product. After you unpack and examine the - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 12
2 3 4 1 10 6 7 9 8 5 Figure 1. Product Components 11 12 gud003.eps 4 - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 13
International Power Plug Adapters 985 Getting Started 985 User Manual CD Product Carrying Case Airborne Particle Counter Product Overview The Buttons See submenus. Enter/Select- Push to select a menu option. Also use to start and stop a sample when in the Sample Screen. Navigation- - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 14
985 Users Manual Product Connections Power and data connections are on the bottom of the Product and on the rear of the Charge Base. The Ethernet connection is - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 15
only available on the base. Table 5 and Figure 3 show you these connections. Table 5. Charge Base Connections Item Description Ethernet Port DC Power Input USB Port Airborne Particle Counter Product Overview " 12V 1.2A ™ 1 2 3 gud006.eps Figure 3. Charge Base Connections 7 - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 16
985 Users Manual 2. In the Data Display Setup screen, enable the 0.3 μm channel and set Concentration mode to COUNTS. 3. In the Sample Setup screen: 1. Set the sample particle >0.3 μm in 5 minutes How to Purge the Product Sensor Particles must be purged (removed) from the Product sensor before use - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 17
The navigation menu lets you move through the five different sections of the Product software. To go to the Navigation menu, push . The live navigation icon in have submenus. See the "Sample Setup Submenus" section. Airborne Particle Counter Operation Icon Table 6. Main Menu Icons Menu Item - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 18
985 Users Manual To get in to the navigation menu and select a menu option: 1. Push . 2. Push fields, check boxes and drop down menus. An onscreen keyboard shows when a text field is necessary. Use the keyboard to record data in the field. Sample Screen Menu The sample screen is the default screen - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 19
To exit this menu, keep highlighted and push . The Product goes to the buffered data screen. Airborne Particle Counter Operation Setup Menus There are two setup menus: • Sample Setup • Communication Setup Use these menus and their submenus to configure the Product. Note In the setup menus there is - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 20
985 Users Manual Option Method Hold Delay Cycles Mode Table 7. Sample Options the Product samples refer to the recorded parameters. Manual: the Product samples once and stops. Beep: Uses Automatic mode settings but ignores count alarm settings. The Product beeps for each particle counted. 12 - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 21
about these submenus. Table 8. Sample Setup Submenus Icon Submenu Item Alarm Setup Data Display Setup Location Setup Airborne Particle Counter Operation Alarm Setup Submenu The Product Alarm can be set to trigger from different particle dimensions. To update or change a parameter: 1. From the - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 22
985 Users Manual The Data Display Setup screen includes check boxes, radio buttons and Sample Volume field, but less than the next largest particle size. Location Setup Submenu Sample location can be recorded for the samples. If the Product is used in multiple areas, it will make the samples clear - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 23
an IP address, Subnet, and Gateway manually. Airborne Particle Counter Operation General Setup Submenu Product hardware setup can is "123456". If password is changed and lost, contact Fluke Customer Service to reset it. See the "How to Contact Fluke" section. • Feedback Volume: Mute, Low, Medium, - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 24
985 Users Manual The submenu also shows dynamic data that you can see as a sample is taken: • Present Battery Voltage • Calibration: OFF or a voltage during a live sample • Laser Current: OFF or mA during a live sample • Motor Current • Pump Hours (cumulative) • Laser Hours (cumulative) • - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 25
Refer to the Help screen for more information about Graph Setup. Airborne Particle Counter Operation The right side of the trend graph is fixed at of samples displayed is 255. Use and to adjust the Y axis scale. Note If historical location data is selected for review at the Trend setup screen, - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 26
985 Users Manual Data Export The Product stores collected data in flash memory. "Product Connections" and "Charge Base Connections" sections. When you connect the USB cable, you will see . 2. Use Windows Explorer to go to the HPC USB Drive. 3. Windows Explorer will open and show you the Data.tsv file - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 27
Product IP address and subnet will need to be set manually. 1. The Charge Base must be used for Ethernet connectivity. Connect the Ethernet cable to the will see the Ethernet connection icon on the lower display ( ). Airborne Particle Counter Data Export 2. With a web browser, go to the internet - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 28
985 Users Manual Figure 5. Exported Data report.jpg 20 - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 29
. Do not put in sunlight. • Do not disassemble or crush battery cells and battery packs. Airborne Particle Counter Maintenance For safe operation and maintenance of the product: • Repair the Product before use if the battery leaks. • Connect the battery charger to the mains power outlet before the - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 30
985 Users Manual Specifications General Particle-Size Range 0.3, 0.5, 1.0, 2.0, 5.0, 10.0) µm Channels 6 Flow Rate 0.1 cfm (2.83 L/min) Light Source 775 nm to 795 nm, 90 mW class 3B laser Calibration PSL particles in air (NIST traceable) Counting Efficiency 50 % @ 0.3 µm; 100 % for particles - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 31
Airborne Particle Counter Specifications Weight 680.39 g (1.5 lb) Environmental IP Rating 40 Operating Humidity 95 % RH non-condensing Protection Class -Ion 7.4 V, 2600 mAh Charge time 3.5 hours Battery Duration 5 hours continuous sampling. 10 hours with typical use model. Agency Approvals 23 - Fluke 985 | Fluke 985 - Airborne Particle Counter - Manual - Page 32
985 Users Manual 24
March 2012
© 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
985
Airborne Particle Counter
Users Manual