    374 FC/375 FC/376 FC Clamp Meter PN 4705494 September 2015 © 2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 2
    any other warranty on Fluke's behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO
  • Fluke IB376K | Product Manual - Page 3
    Table of Contents Title Page Introduction ...1 Contact Fluke ...2 Safety Information ...3 Replacement Part List 9 The Product ...10 Specifications ...22 i MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 4
    2500 A ac. The Flexible Current Probe provides increased display flexibility and allows measurements of awkward sized conductors and improved wire access. The illustrations in this manual show the 376 FC. 1 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 5
    Product or the equipment under test. Symbols used on the Product and in this manual are explained in Table 1. XWWarning To prevent possible electrical shock, fire, or personal injury: • Carefully read all instructions. • Read all safety information before you use the Product. • Use the Product only
  • Fluke IB376K | Product Manual - Page 6
    374 FC/375 FC/376 FC Users Manual • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory. • Comply with local and national safety
  • Fluke IB376K | Product Manual - Page 7
    Clamp Safety Meters Information • Connect the common test lead before the live test lead and remove the live test lead before the common test lead. • Remove all probes, test leads, and accessories before the battery door is opened. • Keep fingers behind the finger guards on the probes. • Hold the
  • Fluke IB376K | Product Manual - Page 8
    374 FC/375 FC/376 FC Users Manual For safe operation and maintenance of the Product: • Repair the Product before use if the battery leaks. • Have an approved technician repair the Product. WCaution
  • Fluke IB376K | Product Manual - Page 9
    . HAZARDOUS VOLTAGE. Risk of electric shock. W WARNING. RISK OF DANGER.   Battery. Low battery when shown on display. Certified by TÜV SÜD Product Service. Do not apply to or remove from - HAZARDOUS LIVE conductors. Do not apply around or remove from uninsulated hazardous live conductors
  • Fluke IB376K | Product Manual - Page 10
    374 FC/375 FC/376 FC Users Manual Symbol Meanin Table 1. Symbols (Cont.) g Symbol Meaning  Measurement Category III is applicable to test and measuring circuits connected to the distribution part of the building's
  • Fluke IB376K | Product Manual - Page 11
    Clamp Meters Replacement Part List Replacement Part List Table 2 lists the available replacement parts. Table 2. Replacement Parts Item Qty. Fluke Part or Model Number Battery, AA 1.5 V Battery Door Assembly Test lead set Flexible current probe i2500-10 Flexible current probe i2500-18 Magnet
  • Fluke IB376K | Product Manual - Page 12
    374 FC/375 FC/376 FC Users Manual The Product Clamp Meter 10 fig01.eps MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 13
    Clamp Auto Power Off 20 ON Backlight Meters The Product ON fig02_3.eps 11 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 14
    374 FC/375 FC/376 FC Users Manual Display Hold 12 MIN MAX AVG = 1x = 2x = 3x 2 sec = Exit fig04_5.eps MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 15
    Clamp LOG (375 FC and 376 FC) 2 sec = LOG Meters The Product Clear Memory (375 FC and 376 FC) + ON + x1 x2 5 sec fig_16.eps 13 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 16
    374 FC/375 FC/376 FC Users Manual Flexible Current Probe 1 2 0.5 A 14 3 fig06.eps MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 17
    Clamp Jaw 0.5 A Meters The Product Hz (375 FC & 376 FC) > 5 A > 20 A 1 2 fig07.eps 15 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 18
    374 FC/375 FC/376 FC Users Manual 3 1 2 0.5 A 16 Fig08.eps MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 19
    Clamp Meters The Product mV dc (375 FC & 376 FC) fig09_10.eps 17 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 20
    374 FC/375 FC/376 FC Users Manual e 18 ON
  • Fluke IB376K | Product Manual - Page 21
    Clamp Meters The Product On Off 3 100 ms 1 4 2 fig13_14.eps 19 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 22
    374 FC/375 FC/376 FC Users Manual 3 1 2 20 fig11_12.eps MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 23
    Clamp Fluke ConnectTM Bluetooth® Connection to FC Tools 1 Fluke Connect TM 2 Connect 3 4 CAPTURE SAVE 5 6 Meters The Product FC Module SAVE flukeconnect.eps 21 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 24
    374 FC/375 FC/376 FC Users Manual Specifications Maximum voltage between any Terminal and Earth Ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating Temperature 10 °C to +50 °C Storage Temperature 40 °C to +
  • Fluke IB376K | Product Manual - Page 25
    Clamp Meters Specifications Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000V / CAT IV 600V IEC 61010-2-033: CAT III 1000V / CAT IV 600V Intrusion Protection (IP) Rating IEC 60529: IP30 Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE Wireless Radio Frequency
  • Fluke IB376K | Product Manual - Page 26
    374 FC/375 FC/376 FC Users Manual Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C AC Current via Jaw Range 374 FC and 375 FC 600.0 A 376
  • Fluke IB376K | Product Manual - Page 27
    Clamp AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤999.9 A) 1 A (≤2500 A) Accuracy 3 % ±5 digits (5 to 500 Hz) Crest Factor (50 Hz/60 Hz 3.0 @ 1100 A 2.5 @ 1400 A 1.42 @ 2500 A Add 2 % for C.F. >2 Meters Specifications 25 MyFlukeStore Shop for Fluke products online at
  • Fluke IB376K | Product Manual - Page 28
    374 FC/375 FC/376 FC Users Manual Position Sensitivity A B C Figure 1. Position Sensitivity ghn12.eps 26 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke IB376K | Product Manual - Page 29
    Clamp Meters Specifications Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 % Measurement uncertainty assumes centralized primary conductor at
  • Fluke IB376K | Product Manual - Page 30
    374 FC/375 FC/376 FC Users Manual AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1.5 % ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±5 digits mV dc (
  • Fluke IB376K | Product Manual - Page 31
    Clamp Frequency via Jaw Range 375 FC and 376 FC 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A Frequency via Flexible Current Probe Range 375 FC and 376 FC 5.0 Hz to 500.0 Hz Resolution 0.1 Hz
  • Fluke IB376K | Product Manual - Page 32
    374 FC/375 FC/376 FC Users Manual Resistance Range 374 FC 6000 Ω 375 FC and 376 FC 60 kΩ Resolution 374 FC 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 375 FC and 376 FC 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ)
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

PN 4705494
September 2015
© 2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
374 FC/375 FC/376 FC
Clamp Meter
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com