Frigidaire AEQ6700FS Data Sheet

Frigidaire AEQ6700FS - 27" Electric Dryer Manual

Frigidaire AEQ6700FS manual content summary:

  • Frigidaire AEQ6700FS | Data Sheet - Page 1
    the cycle selector knob 2 turns counterclockwise. The error code will appear in the digit display. Troubleshoot problem by using chart below. To move on to on electric models and 120V on gas models, replace electronic control. If meter reads zero, remove power from dryer. Disconnect wire going to
  • Frigidaire AEQ6700FS | Data Sheet - Page 2
    ; heat source is on. Drying LED is lit. Control thermistor reading is displayed. 7-11 turns: All LED's will flash To EXIT test mode, press and hold the Select and Cancel buttons simultaneously for 6 seconds or disconnect power from dryer. Dryer will be reset for regular operation. 134682200 0512
  • Frigidaire AEQ6700FS | Data Sheet - Page 3
    en court-circuit E25 Le circuit de la commande NTC est ouvert E4A Défectuosité de temps d'arrêt du programme E5B Défectuosité de séchage comme l'absence de chaleur, un évent obstrué, une pale de soufflerie brisée ou relâchée, la sécheuse installée dans une armoire avec une porte pleine
  • Frigidaire AEQ6700FS | Data Sheet - Page 4
    NOTA : Durant le fonctionnement normal, les codes suivants peuvent s'afficher à l'écran: "ad" - la sécheuse est en cycle de séchage automatique. "dn" - le cycle est effectué en séchage automatique. "PF" - une panne d'alimentation à la carte est survenue. "Err" - une erreur a été détectée. "LOC" - le
  • Frigidaire AEQ6700FS | Data Sheet - Page 5
    y Cancelar durante 6 segundos. Código de Error E10 E11 E12 E24 E25 E4A E5B E68 E8C EAF Etiqueta Descripción Solución del calentador) en el control electrónico. Si el medidor dice 240V en los modelos eléctricos y 120V en los modelos a gas, cambie el control electrónico. Si el medidor dice
  • Frigidaire AEQ6700FS | Data Sheet - Page 6
    tico. "dn" - el ciclo está en secado automático. "PF" - se ha producido una falla eléctrica en el tablero. "Err" - se ha detectado un error. "LOC" - el cierre de control está activado. "PAU" - el ciclo se ha interrumpido. SECUENCIA DE PRUEBA DE FUNCIÓN 1. Presione y mantenga presionado los botones
  • Frigidaire AEQ6700FS | Data Sheet - Page 7
  • Frigidaire AEQ6700FS | Data Sheet - Page 8
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

134682200 0512
Dryer Tech Data Sheet
This information is intended for Qualified Technicians Only.
CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING
Please Return This Sheet to its Envelope in the Product for Future Reference
READING ERROR CODES
1. Press and hold the
Select
and
Cancel
buttons simultaneously for 6 seconds to reset control. The buzzer will sound 1 time
and “
rES
” will be shown briefly in the display.
2. Immediately after, rotate cycle selector knob 2 turns counter-clockwise to the third position from the top, and then
press and hold the
Select
and
Cancel
buttons simultaneously for 6 seconds. The control will enter Field Test Mode, the
buzzer will sound 3 times, and the digital display will alternate between “
Fld
” and the firmware revision number (ex. “
r03
”).
3. Rotate the cycle selector knob 2 turns counterclockwise. The error code will appear in the digit display.
Troubleshoot problem by using chart below.
To move on to the next code, press the
Options
button.
To clear code, press the
Select
button. Code will be cleared when mode is exited.
To exit this mode, simultaneously press and hold the
Select
and
Cancel
buttons for 6 seconds.
Error Code
Label
Description
Solution
E10
General EEPROM
Fault
Problem with communication
between EEPROM and the
microprocessor.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
E11
Checksum Error
Problem with communications or
memory did not check, one has
become corrupted.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
E12
Non fatal R/W
error
Problem reading or writing to the
memory or input/output.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
E24
Control NTC Short
Circuit
Control thermistor or its wiring is
shorted.
Remove wires from control thermistor. Measure resistance of thermistor. If
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±
10%), check wiring between thermistor and electronic control. If good,
replace electronic control.
E25
Control NTC Open
Circuit
Control thermistor or its wiring is
open.
Remove wires from control thermistor. Measure resistance of thermistor. If
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±
10%), check wiring between thermistor and electronic control. If good,
replace electronic control.
E4A
Program Timeout
Fault
The drying time has exceeded
program time for that cycle.
Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes.
Position cycle selector to NORMAL, temperature selector to HIGH HEAT
and touch START. Check for anything that would extend dry times such as:
no heat, restricted vent, blower fan blade broken or loose, dryer installed in
closet with solid door, or bad connection in moisture sensor bar circuit or
dirty bars. If dryer operates normally but code returns, replace electronic
control.
E5B
Heater Fault (no
heating)
Temperature reading of control
thermistor has not changed in a
certain amount of time.
Position cycle selector to NORMAL, temperature selector to HIGH HEAT
and touch START. Measure voltage across terminals on relay RL2 (heater
relay) on electronic control. If meter reads 240V on electric models and
120V on gas models, replace electronic control. If meter reads zero, remove
power from dryer. Disconnect wire going to NO terminal on the relay RL2.
Reconnect power and measure voltage drop between terminal COM on
relay RL2 and neutral. If meter reads zero, wire between incoming line and
relay RL2 is open. If meter reads 120V, check the rest of the heater circuit.
E68
Key (button) Struck
Fault
One of the keys (buttons) is stuck
closed (active).
Enter function test mode and perform key (button) test to determine which
button is at fault. Carefully free the and perform the test again. If button is
free but the key struck code still exists, replace electronic control.
E8C
Too many trips in a
period of time.
The safety (high limit) thermostat
has tripped too many times within
a certain period of program time.
Check for blocked lint filter, blocked exhaust, air leaks around air duct,
broken blower fan blades, worn or loose drum seals, dryer installed in closet
with solid doors or door seal not correctly seated.
EAF
Watch Dog Reset
Microcontroller has been reset by
internal Watchdog timer.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
NOTE:
During normal operation, the display may show:
ad
” - dryer is in an auto dry cycle.
dn
” - cycle is done in auto dry.
PF
” - a power failure to the board has occurred.
Err
” - an error has been detected.
LOC
” - control lock is activated.
PAU
” - cycle has been interrupted.