Frigidaire FAS226R2A Installation Instructions

Frigidaire FAS226R2A - Heavy Duty Room 22,000 BTU Air Conditioner FAS226 Manual

Frigidaire FAS226R2A manual content summary:

  • Frigidaire FAS226R2A | Installation Instructions - Page 1
    Opening: 19" 18 1/2" Min. Window Width: 31" Max. Window Width: 43" 26 1/2" 40 1/2" 1. Check window opening size - the mounting parts furnished with this air conditioner are made to install in a wooden sill double-hung window.The standard parts are for window dimensions listed above.Open sash
  • Frigidaire FAS226R2A | Installation Instructions - Page 2
    . (See Owner's Guide for serial plate location.)Power cord is 48"long. Be sure you have an outlet near. All models have a 3-prong service plug to provide proper service and safe positive grouding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match
  • Frigidaire FAS226R2A | Installation Instructions - Page 3
    the side of the cabinet (see Figures 7-8). Do both sides. FIG. 7 PLASTIC FRAME WINDOW FILLER PANEL 9. Your unit may come with internal packaging.THIS PACKAGING MUST BE REMOVED PRIOR TO INSTALLING THE AIR CONDITIONER BACK INTO THE CABINET. (See FIG. 5).. Internal Packaging FIG. 5 FIG. 8 3 SIDE
  • Frigidaire FAS226R2A | Installation Instructions - Page 4
    tighten. Allow leg to slide freely. Screws will be tightened after Section 6. 4 Place Cabinet in Window 1. Open window and mark center of window stool. 5 Install Support Bracket 1. Hold each support bracket flush against outside of sill, and tight to bottom of cabinet as shown below. Mark
  • Frigidaire FAS226R2A | Installation Instructions - Page 5
    Filler Panels 1. Carefully raise window to expose filler panel locking screws. Loosen screws so filler panels slide easily. LOCKING SCREWS 8 Install Chassis into Cabinet and Install Front to Unit 1. Lift air conditioner and carefully slide into cabinet leaving 6" protruding. 2. DO not push
  • Frigidaire FAS226R2A | Installation Instructions - Page 6
    Location This air conditioner has a slide-out chassis, so that it can be installed through an outside wall as specified below: Heavy Duty (FAS) Median (FAM) Max wall thickness 12" 10" IMPORTANT: SIde louvers must never be blocked. NOTE: All parts needed for Thru-The-Wall Installation are
  • Frigidaire FAS226R2A | Installation Instructions - Page 7
    OVER BOTTOM OF FRAME OVER 81/2" 3 Prepare and Install Cabinet Refer to Step 4 of Window Mounting for assembly of support brackets.A wooden strip nailed to the outside wall should be used in conjunction with sill support angle brackets. 1. Slide chassis from cabinet. Refer back to Step 1 of
  • Frigidaire FAS226R2A | Installation Instructions - Page 8
    Window Mounting Instructions for bottom rail seal location. Masonry Construction 1. Cut or build a wall opening in the masonry wall similar to the frame construction(refer to Step 2 of Thru-the-Wall Installation for a wall . 3. Install a linted to support masonry wall above cabinet. Existing holes in
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Installation Instructions
For Heavy Duty (FAS Models) and
Median (FAM Models) Air Conditioners
Please read ALL instructions before installing.Two people are
recommended to install this product.If a new electrical outlet
is required,have the outlet installed by a qualified electrician
before installing unit. See#5 in Preliminary Instructions
following.
Preliminary instructions
Do the following before starting to install unit.See illustrations
below.
with this air conditioner are made to install in a wooden
Check dimensions of your unit to determine model type:
1
.
Check window opening size
-
the mounting parts furnished
sill double-hung window.The standard parts are for
window dimensions listed above.Open sash to a minimum
of 19"(483mm). (FIG. 1)
2
.
Check condition of window -
all wood parts of window
must be in good shape and able to firmly hold the needed
screws.If not, make repairs before installing unit.
3
.
Check your storm windows -
if your storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG.2, or by removing
storm window while room air conditioner is being installed.
(continued)
Unit Height:
Unit Width:
Min. Window Opening:
Min. Window Width:
Max. Window Width:
Heavy duty (FAS)
Median (FAM)
18.5/8"
17.5/8"
26
1
/
2
"
23
1
/
2
"
18
1
/
2
"
26
1
/
2
"
40
1
/
2
"
19"
31"
43"
FIG. 1
FIG. 2
SASH
19" MIN
1/2" MIN
STORM WINDOW FRAME OR
OTHER OBSTRUCTION
SASH
1/2" MIN
19" MIN
STORM WINDOW FRAME OR
OTHER OBSTRUCTION
1 1/2" MIN
BOARD THICKNESS AS
REQUIRED, ALONG
ENTIRE STOOL, FASTEN
WITH TWO NAILS OR
SCREWS.
1
SEAL-BOTTOM RAIL TO UNIT
SIDE RETAINER
FRAME
ASSEMBLY
(LEFT)
WASHER HEAD
LOCKING SCREW
FOAM GASKET
TOP ANGLE
FRAME
ASSEMBLY
(LEFT)
SAFETY LOCK AND
3/4" LONG HEX HEAD
SCREW
1/2" LONG
SCREWS AND
LOCKNUTS
LOCKNUT
3/4" LONG
FLAT HEAD
BOLT
WINDOW SUPPORT
BRACKET
WINDOW SASH SEAL
SILLANGLE
BRACKET
P/N
66121625