Frigidaire FAX052P7A Installation Instructions

Frigidaire FAX052P7A - Window Unit Air Conditioner Last One Left Manual

Frigidaire FAX052P7A manual content summary:

  • Frigidaire FAX052P7A | Installation Instructions - Page 1
    Installation Instructions READ BEFORE INSTALLING UNIT OPP5K Window Mounting Your air conditioner is designed to install in standard double hung windows rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors
  • Frigidaire FAX052P7A | Installation Instructions - Page 2
    the other side. NOTE: If storm window blocks AC, see FIG. 14. 2 Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (FIG. 6 & FIG. 6A). Carefully close the window behind the top rail of the
  • Frigidaire FAX052P7A | Installation Instructions - Page 3
    (13 mm) locking screws through frame holes into window sash (FIG. 10/11). FIG. 10 FIG. 11 If AC is Blocked by Storm Window Add wood as shown in FIG. 14, or remove storm window before air conditioner is installed. FIG. 14 SASH STORM WINDOW FRAME OR OTHER OBSTRUCTION 1 1/2" MIN (38 mm) BOARD
  • 1
  • 2
  • 3

1
Installation Instructions
READ BEFORE INSTALLING UNIT
Your air conditioner is designed to install in standard
double hung windows with opening widths of 2
3
to 36
inches (
584
mm to 914 mm) (FIG. 1)
Lower sash must open sufficiently to allow a clear vertical
opening of 14-1/2 inches (368 mm).
Side louvers and the
rear of the AC must have clear air space to allow
enough airflow through the condenser, for heat removal.
The rear of the unit must be outdoors, not inside a
building or garage.
TOOLS NEEDED:
Phillips Screw Driver
Drill (If pilot holes are needed)
Qty.
3/4"screws
7
lock frame
2
sash lock
1
Mounting Hardware
When handling unit, be careful to avoid cuts
from sharp metal edges and aluminum fins on
front and rear coils.
NOTE:
SAVE CARTON and these INSTALLATION
INSTRUCTIONS for future reference. The carton is the
best way to store unit during winter, or when not in use.
Some assembly is required. Please read these instructions
carefully.
TOOL NEEDED:
Phillips Screwdriver
A.
Remove the air
conditioner from the
carton and place on a
flat surface.
B.
Remove top rail from
the bottom of the
packaging material as
shown in Fig. A
C.
Align the hole in the
top rail with those in
the top of the unit as
shown in Fig. B
D.
Secure the top rail to
the unit with the 3/8"
Screws as shown in
Fig. C
Top Rail Hardware
Qty.
3/8” Screw
4
Top Rail
1
CAUTION
NOTE: FOR SAFETY REASONS, ALL
FOUR (4) SCREWS
MUST BE SECURELY
FASTENED.
Before installing unit, the top rail must be
assembled on the unit.
Fig. B
Fig. C
OPP5K Window Mounting
Fig. A
Packaging
Top Rail
P/N
6612
9901121
Fig.
1