    (For 3 or 4 Wire, 60 Hz. Systems) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Clearances and Dimensions 1. Provide adequate clearances between the range and
  • Frigidaire FEF326AB | Installation Instructions - Page 2
    consumer. Important Note to the Consumer Keep these instructions with your owner's guide for future reference. • As when using any appliance generating heat, there are certain safety precautions you should follow. These are listed in the Use & Care Manual, read it carefully. • Be sure your range is
  • Frigidaire FEF326AB | Installation Instructions - Page 3
    to be replaced properly and could create a potential electrical hazard if wires become pinched. Connect only as instructed under "PERMANENT RANGE CORD KIT IS USED, THE INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED OR STRAIN RELIEF BRACKET IS DISCARDED. This appliance may be connected by means of a power
  • Frigidaire FEF326AB | Installation Instructions - Page 4
    of the appliance with the ground screw using the same hole in the frame where the ground screw was originally installed (See Fig. 12). 5. Make sure all screws are tightened securely and replace the rear access cover (See Fig. 9). or 4B. POWER CORD CONNECTIONS (3-Wire Connection Instructions . For
  • Frigidaire FEF326AB | Installation Instructions - Page 5
    Connections) Follow the manufacturer's installation instructions supplied with the strain relief and the ground wire lead (Green) to the frame of the appliance using the ground screw & plate as shown in Fig. Make sure all connections are tightened securely and replace the rear access cover (See Fig.
  • Frigidaire FEF326AB | Installation Instructions - Page 6
    30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS (For 3 or 4 Wire, 60 Hz. Systems) 6
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
(For 3 or 4 Wire, 60 Hz. Systems)
1
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
P/N
316259206 (1103) EN
Clearances and Dimensions
1.
Provide adequate clearances between the range and adjacent combustible surfaces.
2.
Location—Check location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3.
Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.
*30" MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE
BOTTOM OF AN UNPROTECTED
WOOD OR METAL CABINET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT
LESS THAN 1/4" FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
STAINLESS STEEL, 0.024" ALUMINUM OR 0.020" COPPER. 0" CLEARANCE IS THE MINIMUM FOR THE REAR OF THE
RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE, POTENTIAL
FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE
SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED,
THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5"
BEYOND THE BOTTOM OF THE CABINETS.
Español - Páginas 7-12
30-1/8"
Fig. 1
Fig. 2
Fig. 3
30"
48-1/2"
*
*Depth is 28-13/32"
with door handle