    All about the Installation of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. 2020323B2335 (June 2009) www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 2
    of the information required to guarantee your safety and the appropriate use of your air conditioner. Please read all of the instructions before using the air conditioner and keep this manual for future reference. We know you will enjoy your new air conditioner and thank you for choosing our product
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 3
    Contents 01. Welcome 01 02. Environmental advices 01 03. Contents 02 04. Safety precautions 03 05. Installation: 5.1 Choosing the installation site 04 5.2 Parts list 06 5.3 Indoor unit installation 08 5.4 Outdoor unit installation 12 5.5 Refrigerant piping connection 14 5.6 Electrical work
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 4
    power at the electrical box. 7. In the event of a malfunction (sparks, burning smell, etc.) immediately power off unit and call an authorized Frigidaire servicer. 8. Do not operate the air conditioner with wet hands. 9. Do not drink any water or condensation that is drained from the air conditioner
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 5
    installation site Installation Warnings 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. all safety notices. Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install the unit at one of these sites,
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 6
    unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. The site must be kept away from flammable gases. 4. The site must provide
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 7
    (half union) 8. A glass of water 9. Hexagonal wrench (4mm) 10. Gas-leak detector 11. Vacuum pump 12. Gauge manifold 13. Users manual 14. Thermometer 15. Multimeter 16. Pipe cutter 17. Measuring tape Accessories Number Name of Accessories Quantity 1 Indoor unit mounting plate 1 2 Clip anchor
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 8
    above 30cm above 16 above 2m 50cm above Space to the wall 15 Air outlet side 12 14 NOTE 13 All the pictures in this manual are for explanation purposes only. The actual shape of the indoor unit you purchased may be slight different on front panel and display window.The
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 9
    Indoor unit installation Wall mounting brackets and dimensions B B 4.21" 4.21" B Indoor unit outline 6" or more from the wall Refrigerant pipe hole (right) Ø 2.56" 6" or more from the ceiling Wall mounting bracket 3.39" A 3.39" ≤12000 Btu's (A:33.31" B:10.83") 6" or more from the wall
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 10
    on the bracket, as shown in figure 1.3. 2. In the case of tiled, concrete or similar walls, create 13/64" diameter holes. Place anchor supports for the appropriate assembly screws. 3. Install the wall mounting bracket to the wall with eight A type screws. 4. At all times securing to the wall
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 11
    Connective pipe and drainage installation Connective pipe 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. The pipe cover can be kept as it may be used when relocating the air conditioner to any other place. 2. For the rear-right-hand and rearleft-hand piping,
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 12
    3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side to side, up and down to check if it is hooked securely. Cushioning material Piping
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 13
    Outdoor unit installation 1. Install the outdoor part of the unit on a flat surface to avoid excess noise and vibration. A condenser pad is recommended. 2. Direct the air vent toward an area without obstacles. 3. Install the unit at the site where it is exposed to as little wind as possible,
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 14
    Condensate drainage of outdoor unit (cooling only excluded) The condensate and defrosting water produced during heating in the outdoor unit can be properly discharged by drainage pipe. Installation method: Insert the drain connection into one of the holes of the chassis and then connect drainage
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 15
    Refrigerant piping connection Unit comes with 25' tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 16
    4. Flaring work. Firmly hold copper pipe in a die in the dimension shown in the table below. OUTER DIAMETER (inch) 1/4 3/8 1/2 5/8 A (inch) Max. Min. 0.051 0.063 0.071 0.095 0.028 0.039 0.039 0.087 Connection Adjustment 1. Align the pipes to be connected. 2. Screw the flare nut with your
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 17
    about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved. 2. Power voltage should meet the requirements in table 2.1. 3. Over current protection and circuit disconnect should meet the requirements in table 2.1 and
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 18
    Connect the cable to the indoor unit 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible type cord. 3. Lift the indoor unit panel up, remove the
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 19
    Connect the cable to the outdoor unit 1. Remove the electrical control board cover from the outdoor unit by loosening the screw. 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. The connective
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 20
    the wiring as follows: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2. The screws which fasten the wiring in the casing of electrical fittings are liable
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 21
    and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage. 2. When relocating
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 22
    5. Pipe length and refrigerant amount for multi split type air conditioner. (see tabel 2.3) Table 2.3 Cooling capacity Connective pipe (BTU/h) length (Lx) Max connective pipe total length (H1) Max height difference (H2) Air purging Additional amount of refrigerant to be charged 26000 25'~
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 23
    When using the vacuum pump For method of using a manifold valve, refer to its operation manual. 1. Completely tighten the flare nuts at connection point A, B, C and D. Connect valve core removal tool to the charging port, then connect vacuum hose to valve core
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 24
    Electrical safety Perform the electric safety check after completing installation: 1. Insulated resistance: The insulated resistance must be more than 2M. 2. Grounding work: After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make
  • Frigidaire FFHP124CS1 | Installation Instructions - Page 25
    . 3. When the ambient temperature is too low(lower than 63 oF), the unit cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken. Manual operation is used only when the remote controller is disable or maintenance necessary. Auto/OFF
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

Refer to Page 2 for table of contents.
www.frigidaire.com
USA 1-866-942-1567
www.frigidaire.ca Canada 1-866-942-1567
2020323B2335 (June 2009)
All about the
Installation
of your
Split Type Room Air Conditioner