Frigidaire FFRA2822U2 Installation Instructions

Frigidaire FFRA2822U2 Manual

Frigidaire FFRA2822U2 manual content summary:

  • Frigidaire FFRA2822U2 | Installation Instructions - Page 1
    Instructions For BY Platform (15,000-18,500 BTU) + BN Platform (22,000-28,500 BTU) Air Conditioner READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual will be installed. Be sure it will support the weight of the unit overan extended period
  • Frigidaire FFRA2822U2 | Installation Instructions - Page 2
    Care Guide for serial plate location.) Power cord is 48" long. Be sure you have an outlet near. All models have a 3-prong service plug to provide proper service and Accessory Kit includes Hardware bag(shipped inside window support brackets) Window support bracket (2) Foam gasket Window sash seal
  • Frigidaire FFRA2822U2 | Installation Instructions - Page 3
    Installation Instructions Window Mounting 1 Remove Air Conditioner from Cabinet NOTE: 5. Rotate Front Panel up until top tabs are free. Pull panel straight out. Depress latch on electronics plug (on some models) to disconnect. 6. Remove Front Panel from unit (see Fig. 4). FIG.3 FIG.4
  • Frigidaire FFRA2822U2 | Installation Instructions - Page 4
    Installation Instructions FIG.9 This side should face to indoor side "I" section Retainer holes in cabinet bottom given the sill width distance. Thread the bolts into the slots of the support brackets. Tighten lock washer nuts onto bolts. 4. Adjust height of sill angle bracket so that bracket
  • Frigidaire FFRA2822U2 | Installation Instructions - Page 5
    Installation Instructions 6 Extend Window Filler Panels and attach to top angle rail: shown (FIG.21). 3. If necessary, trim weather seals to needed length, peel off protective backing, and use to plug any gaps. See Fig. 19. A. 1/2" long hex head screw B. left-hand Window Filler Panel Top Leg C.
  • Frigidaire FFRA2822U2 | Installation Instructions - Page 6
    Installation Instructions 10 In order to minimize air leaks between the room air conditioner and the window opening, suitable weather stripping(trim the provided weather stripping into
  • Frigidaire FFRA2822U2 | Installation Instructions - Page 7
    Installation Instructions Thru-The-Wall Installation NOTE: Consult local building codes prior shims, and 10 wood screws (#10-1" long minimum). Select a wall surface that: 1. Does not support major structural loads such as the frame construction at ends of windows, and under truss-bearing points, etc
  • Frigidaire FFRA2822U2 | Installation Instructions - Page 8
    Installation Instructions 4. Build a wooden frame with the INSIDE dimensions of your about 1/8" - 1/4" 1" LONG WOOD SCREW Side Louvers Refer to Step 5 of Window Mounting for assembly of support brackets. Nail a wooden strip to the outside wall for the angle sill bracket to rest upon. See Fig.
  • Frigidaire FFRA2822U2 | Installation Instructions - Page 9
    Installation Instructions FIG.7 FIG.8 Support bracket Sill angle bracket Wooden strip 6. Install air sides of wood sleeve to the opening. NOTE: See Step 5, Item 4 of Window Mounting Instructions for bottom rail seal location. Masonry Construction 1. Cut or build a wall opening in the masonry
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Preliminary instructions:
READ BEFORE INSTALLING UNIT
1
1.
Check window opening size:
the mounting parts
furnished with this air conditioner are made to install in
a wooden sill double-hung window. The standard parts
are for window dimensions listed above. Open sash to
a minimum of 19-1/4"(489mm). (FIG.1)
NOTE: DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE.
Do the following before starting to install unit. See illustrations below.
Check dimensions of your unit to determine model type:
Unit Height:
Unit Width:
Min. Window Opening:
Min. Window Width:
Max. Window Width:
2.
Check condition of window:
all wood parts of window
must be in good shape and able to firmly hold the needed
screws. If not, make repairs before installing unit.
3.
Check your storm windows:
If your storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown (FIG.2), or by removing
storm window while room air conditioner is being installed.
BY Platform
17-25/32
"
23-5/8
"
19-1/4
"
29
"
41
"
15,000~18,500 BTU
BN Platform
18-5/8
"
26-17/32
"
19-1/4
"
30
"
41
"
22,000~28,500 BTU
sash
1/2" min
storm window frame or
other obstruction
FIG.1
19-1/4" min
inner sill
outer sill
Capacity:
FIG.2
sash
1/2" min
storm window frame or
other obstruction
19-1/4" min
board thickness as
required, along entire inner
window sill; fasten to inner
sill with two nails or screws.
1-1/2" min
inner sill
outer sill
66129926912
For BY Platform (15,000-18,500 BTU) + BN Platform (22,000-28,500 BTU) Air Conditioner
Pay attention to danger and safety notices.
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may
be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install
the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. To
prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit overan extended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.
If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing unit.
Carefully read the installation manual before beginning.
Follow each step as shown.
Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
INSTALLATION WARNINGS AND CAUTION
window sash seal
safety lock and
1/2
"
long hex
head screw
top angle
foam gasket
washer head
locking screw
frame
assembly
(left)
side retainer
bottom rail
seal to unit
frame
assembly
(right)
1/2
"
long
screws and
locknuts
locknut 3/4
"
long flat
head bolt
sill angle
bracket
window
support bracket
Installation Instructions