    to 3°F (-18° to -16°C) Refrigerator Temperature Low Side Pressure (cut-in) Low Side Pressure (cut-out) High Side Pressure (last liner. SERVICE DATA SHEET ICE & WATER - AUTOMATIC Refer to Service Manual for additional home" position. Hold bail arm up. Pass if alarm sounds when tray returns to "home
  • Frigidaire FPSC2277RF | Wiring Diagram - Page 2
    PIN CONNECTION TO ICEMAKER ELECTROMECHANICS LS1 9 PIN LOW SIDE EVAPORATOR COMPARTMENT MC1 12 PIN CONNECTION J8 BOARD - MOUNTED AMBIENT THERMISTOR YEL/PNK YEL/PNK 12 8 J5 +5V DC RH1 LH1 DOOR BACK VIEW MC1 WATER VALVES IM1 IM2 FRONT INSIDE VIEW LS1 FZ1 FZ LED IM1 1 5 9 9 51 4 8 12 12 8
  • 1
  • 2

SERVICE DATA SHEET
A02058901
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE - R134a
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch
to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive
heat will distort the plastic liner.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT
0°F FREEZER & 37°
F
FRESH FOOD
(2500 ++ ISO)
Type A with Run / Start Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Variable Speed
Standard
Variable Speed
Standard
Operating Time
74 to 84%
32 to 40%
100%
55 to 65%
Freezer Temperature
-2° to 2°F
(-19° to -17°C)
0° to 4°F
(-18° to -16°C)
-1° to 3°F
(-18° to -16°C)
-1° to 3°F
(-18° to -16°C)
Refrigerator Temperature
34° to 39°F
(1° to 4°C)
34° to 39°F
(1° to 4°C)
34° to 39°F
(1° to 4°C)
34° to 39°F
(1° to 4°C)
Low Side Pressure (cut-in)
5 to 12 psig
(43 to 83 kPa)
5 to 12 psig
(43 to 83 kPa)
N/A
5 to 12 psig
(43 to 83 kPa)
Low Side Pressure (cut-out)
-2 to 2 psig
(-14 to 14 kPa)
-2 to 2 psig
(-14 to 14 kPa)
-2 to 2 psig
(-14 to 14 kPa)
-2 to 2 psig
(-14 to 14 kPa)
High Side Pressure
(last 1/3 cycle)
90 to 105 psig
(621 to 724 kPa)
90 to 115 psig
(621 to 793 kPa)
120 to 135 psig
(827 to 931 kPa)
130 to 155 psig
(896 to 1069 kPa)
Wattage (last 1/3 cycle)
50 to 60
90 to 130
60 to 70
100 to 140
Amps (running)
0.5 to 0.9
0.7 to 1.1
0.6 to 1.0
0.8 to 1.2
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size:
26’ SD, 22’ CD
Thermal Cutout
Heater
Defrost
Thermis-
tor
Termina-
tion
Cut-in
Cut-out
Watts
Ohms
Cut-out
110°F (43.3°C)
135°F (57.2°C)
500
26.5
39°F
(4°C)
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW
Opposite Shaft
0.03 Running
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not
attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
SYSTEM DIAGNOSTIC MODE
Activate:
Press
FZ+
and
FZ-
for up to 10 sec. simultaneously.
Press FF+ to advance through tests.
Deactivate:
Press FF+ for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display on the inside of the door for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
Passing result
--
First Screen
--
Blank on both UI displays, no lights illuminated, no shadowing.
--
Second Screen
--
All LED lights on both UI displays illuminated.
--
Third Screen
--
Blank on both UI displays, no lights illuminated, no shadowing.
28
Dispenser Paddle
Press disp. paddle
“on” is displayed on the inside of door UI when depressed; “Water” is
illuminated on Front UI; “off” when released.
34*
Ambient
Thermistor @UI
Activates automatically
UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem
-
perature measured with gauge at UI location. “OP” if open; “SH” if short.
“Cubes” is illuminated on Front UI.
46
Humidity Sensor
Activates automatically
“OP” if open, “SH” if short.
Displays %RH.
“Crushed” is illuminated on Front UI.
36
Ice Chute Door
Depress ice chute door
or press Power On-Off
“OP” on UI when manually opened; “CL” when closed. Or, using “Power
On-Off”, motor will drive door open “OP” or closed “CL”.
47
Dispenser
Pocket Heater
Press Power On-Off
Heater on when “on”, off when “off”.
66
Dispenser Light
Press Power On-Off
Dispenser light on when “on”, off when “off”.
5-
Firmware Front UI
Press Power On-Off
Displays digit sequence; record.
6-
Factory Firmware
Front UI
Press Power On-Off
Displays digit sequence; record.
1*
Standard Compressor
and Condenser Fan
Press Power On-Off
Compressor and Condenser Fan running when “on”, stopped when “off”.
2
Freezer Defrost
Heater
Press Power On-Off
Freezer defrost heater on when “on”; off when “off”.
3*
FF Light
(Incandescent Models)
Press Power On-Off
FF lights on when “on”; off when “off”
8
Water Valve
(Dispenser)
Press Power On-Off
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”.
9*
FZ Light
(Incandescent Models)
Press Power On-Off
FZ lights on when “on”, off when “off”.
10
Auger Motor
Press Power On-Off
FZ door must be closed.
Motor running when “on”; motor stopped when “off”.
11
Cube/Crush
Solenoid
Press Power On-Off
Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”.
12*
VCC Condenser Fan
Press Power On-Off
Fan running when “on”; stopped when “off”.
38*
VCC Compressor
Press Power On-Off
Compressor running when “on”; stopped when “off”.
13*
FF Light (LED Models)
Press Power On-Off
FF lights on when “on”; off when “off”.
15
Evaporator Fan
Press Power On-Off
Stopped when “off”. Listen for speed change from “LO” to “HI”.
20*
FZ Light (LED Models)
Press Power On-Off
FZ lights on when “on”, off when “off”.
22
Damper
Press Power On-Off
With inspection mirror, observe damper open when “OP”; closed when “CL”.
67
Fill Tube Heater
Press Power On-Off
Heater on when “on”, off when “off”.
23
FF Door
Open/close FF door
“CL” on UI when door closed; “OP” when open.
24
FZ Door
Open/close FZ door
“CL” on UI when door closed; “OP” when open.
29
FF Thermistor
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at FF thermistor location.
“OP-” if open; “SH-” if short.
30
FZ Thermistor
Activates automatically
UI shows temperature sensed by FZ thermistor; pass if within 10°F of
temperature measured with gauge at FZ thermistor location.
“OP” if open; “SH” if short.
33
Ambient Thermistor
@ Main Board
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/-10°F
of temperature measured with gauge at main board location.
“OP” if open; “SH” if short.
39
Evaporator
Thermistor
Activates automatically
UI shows temperature sensed by evaporator thermistor; pass if within 10°F
of temperature measured with gauge at evaporator thermistor location.
“OP” if open; “SH” if short.
0-
Firmware Parameters
Press Power On-Off
Displays digit sequence; record.
2-
Main Board Firmware
Press Power On-Off
Displays digit sequence; record.
4-
UI Firmware
Press Power On-Off
Displays digit sequence; record.
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
Replace Inverter Board
Check at Inverter Board on
Compressor
(BLK and RED wires)
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
Check at Main Control Board
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
no
Check at the connector from the power cord
harness into the inverter board, located in
the machine
compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
Check voltage supply.
Check and repair power
cord harness wiring and
connections.
no
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
yes
Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
shown.
Is resistance across all winding
pairs equal?
Replace Compressor and
Inverter Board.
no
Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
yes
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
no
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Replace Main Control Board.
no
yes
yes
yes
ERROR CODES
SPECIAL MODES
Display
Interpretation
Mode
Display
Activate/Deactivate
(press for up to 10 sec. simultaneously)
FZ
FF
FZ
FF
--
OP
Open FF Thermistor
Manual Defrost
d
F
FF+ and FF- / same to deactivate
OP
--
Open FZ Thermistor
Display / Showroom
77
77
FZ+ and FF- / Power-on-Reset (POR)
--
SH
Shorted FF Thermistor
Sabbath
Sb
Sb
FZ- and FF+ / same to deactivate
SH
--
Shorted FZ Thermistor
System Diagnostic
No FF or FZ display,
all UI LEDs on.
FZ+ and FZ- / FF+ to deactivate
SY
CF
UI to Main Control
Board communication
failure; on start up
IM Diagnostic
Numerical display of
first test
FZ+ and FF+ together to activate /
FF+ to deactivate
SY
CE
UI to Main Control
Board communication
error; after a period
in operation
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
SY
EF
Evaporator Fan Failure
ICE MAKER DIAGNOSTIC MODE
Activate:
Press FZ+ and FF+ temperature pads for up to 10 sec. simultaneously.
Press FF+ or - to move forward or backward through tests.
Deactivate:
Press FF+ for up to 10 sec. IM Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
NOTE: Silence alarm.
Test
To activate test
Passing Result
52C
Ice Maker Thermistor
Activates
automatically
FZ display shows temperature sensed by Ice Maker Thermistor.
“OP” if open; “SH” if short
55C
Water Valve
Press Power
On-Off
Remove ice tray to collect water into a measuring container to measure water
fill. If collecting water into ice tray, first perform test 63C to empty ice tray.
57C*
Evaporator Fan (FFIM)
(BM only)
Press Power
On-Off
“On” on FZ display when fan activated, “OFF” when deactivated.
58C
Ice Level Sensor
Activates
automatically
Remove ice bucket.
Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position.
Hold bail arm up. Pass if alarm sounds when tray returns to “home” position.
This test runs continuously until another test is selected.
63C
Twist Tray
Press Power
On-Off
Remove ice bucket.
FZ display shows “1” and “GOOD”.
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.