IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
should not attempt to make repairs
due to the possibility of electrical
shock. Disconnect power cord
before servicing.
SERVICE DATA SHEET
AUTOMATIC DEFROST
SINGLE DOOR
REFRIGERATOR
INSTALLATION
This product is designed for “free standing installation only” and three inches of
clearance must be provided on all sides of the refrigerator for air circulation.
The refrigerator should be positioned on a solid floor, and the front of the cabinet
should be raised just enough to provide easy door closure when open about half
way.
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
TEMPERATURE CONTROL
38.5°F cut in, 32.0°F cut out @ number 1 setting.
DEFROST CONTROL
An automatic 30 minute defrosting period is initiated after every 12 hours of compres-
sor running time. During the defrosting period, a thermostat will switch the defrost
heater off after the frost on the evaporator has melted. The defrost thermostat closes at
10°F and opens at 50°F.
FREEZE CONTROL
When the external temperature falls below 35° ± 3°F a 40 watt auxiliary heater and
the evaporator fan will turn on. Both will run until either:
A)
The interior cabinet reaches the temperature selected by the
temperature control, causing the auxiliary heater to turn off and
the compressor and fan to run.
B)
The external temperature reaches 45° ± 5°F and the fan and auxiliary
heater turns off.
PD636
IMPORTANT
If any green grounding
wires are removed dur-
ing
servicing,
they
must be returned to
their original position
and properly secured.
ELECTRICAL CIRCUIT
Power
Wh
Cold
Control
Blk
Yel
Interior
Light
Door
Switch
Blk
Red
Yel
Blu
Defrost
Thermostat
Wh
Auxiliary
Heater
Brn
Defrost
Heater
See Diagram
Defrost
Timer
On/Off
Thermostat
Yel
Compressor
Or
Ambient
Thermostat
Pur
Fan Relay
Pur
Evaporator
Fan
EC82
Drier
Condenser
Outlet
Charge Tube
Heat Exchanger
Charge
Tube
Discharge
SP24
SYSTEM SCHEMATIC
WIRING DIAGRAM
216946200
C09