GE 600-1054-95R User Manual

GE 600-1054-95R - Simon XT Wireless Home Security System Manual

GE 600-1054-95R manual content summary:

  • GE 600-1054-95R | User Manual - Page 1
    600-1054-95R Simon XT User Manual g
  • GE 600-1054-95R | User Manual - Page 2
    coincidental. GE and the GE monogram are registered trademarks of General Electric Company. Simon and Simon XT are trademarks of GE Security. GE Security Inc., a Delaware corporation. b. "Software" mean the executable software or firmware programs and accompanying documentation installed on the GE
  • GE 600-1054-95R | User Manual - Page 3
    works or programs based on the Software. 5. Limited warranty. GE SECURITY warrants that GE SECURITY. To obtain a repair or replacement of nonconforming Software, contact GE SECURITY Customer Service by any third party. 7. General. Any materials provided to You by GE SECURITY shall not be exported or
  • GE 600-1054-95R | User Manual - Page 4
    iv Simon XT User Manual FCC compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
  • GE 600-1054-95R | User Manual - Page 5
    text display 7 Simon XT features 9 Things you can do 9 Home security 9 Exit/entry delay 11 Bypassing sensors 12 Alarms 13 Light control (optional 14 20 Alarm sirens and lamp modules 21 Panel indicator lights 22 Trouble beeps 23 Programming 25 System menu 26 Entering and exiting the
  • GE 600-1054-95R | User Manual - Page 6
    vi Simon XT User Manual Special chime 30 System tests 30 Revision 30 Contrast 30 System programming 31 Access codes 31 Security 32 Phone numbers 32 Timers 33 Siren options 33 Light control 35 Chapter 5. Testing 37 Testing sensors 38 Testing communication 39 System download 40 Appendix
  • GE 600-1054-95R | User Manual - Page 7
    GE Simon XT User Manual for model 600-1054-95R. This document includes an overview of the product and detailed instructions on how to operate the system. Read these instructions the Customer Support menu, Programming or coding sequences. Safety terms and symbols These terms may appear in this manual
  • GE 600-1054-95R | User Manual - Page 8
    viii Simon XT User Manual
  • GE 600-1054-95R | User Manual - Page 9
    Chapter 1 Introduction This chapter describes the Simon XT's features. In this chapter: Security system components 2 Communicating with your system 4
  • GE 600-1054-95R | User Manual - Page 10
    2 Simon XT User Manual Security system components The Simon XT uses wireless technology to warn your family about intrusion, carbon monoxide, and fire. It may also be used to control lights and appliances within your home. The system communicates with a central monitoring station and sends voice
  • GE 600-1054-95R | User Manual - Page 11
    in Table 1. Table 1. Simon XT system components Component Type Description Control panel Operates and programs your security system. It Modules Appliance a Can be programmed to turn appliances or fluorescent lights on and off. Lamp a Can be programmed to turn nonfluorescent lights on
  • GE 600-1054-95R | User Manual - Page 12
    Simon XT User Manual Communicating with your system Sending commands or instructing the panel. Depending on how your system is programmed, you may need to enter an access code touchpad. Keyfob Keyfobs are handy for simple arming, disarming and light control functions. They are portable and can be
  • GE 600-1054-95R | User Manual - Page 13
    panel This chapter provides instructions for operating your Simon XT Security System. In this chapter: Panel controls 6 Standard text display 7 LEDs 8 Simon XT features 9 Things you can do 9 Home security 9 Exit/entry delay 11 Bypassing sensors 12 Alarms 13 Light control (optional 14
  • GE 600-1054-95R | User Manual - Page 14
    interface for system operation and programming system functions. Table 3 on page 7 provides a description of the panel keys and display. Figure 2. Simon XT self-contained panel MOTIONS DOORS+WINDOWS DISARM STATUS Piezo siren LCD display Emergency Police Microphone Fire Lights on Scroll up Enter
  • GE 600-1054-95R | User Manual - Page 15
    Simon XT panel keys and features Control Description Piezo siren The piezo siren makes alarm beeps and status beeps. Fire and intrusion alarm beeps are always played at high volume, while the volume of status beeps (such as trouble disarmed been programmed. Numeric * Lights on. # Lights off.
  • GE 600-1054-95R | User Manual - Page 16
    8 Simon XT User Manual Arming level text could be one of the following: • Subdisarmed • Disarmed • Doors + Windows • Motions • Doors + Windows & Motions The phrase - No Delay is appended to the arming level when no entry delay is active. Here are the
  • GE 600-1054-95R | User Manual - Page 17
    and exit delays • Light control • Emergency • Bypassing sensors • Chime • Latchkey Things you can do The Simon XT features provide you with you can set from the control panel. Table 4. Simon XT arming levels Level Function 0 Subdisarm 1 Disarm 2 Arm door and window sensors-exterior 3 Arm
  • GE 600-1054-95R | User Manual - Page 18
    Simon XT User Manual Arming/disarming Arming a sensor makes it active and allows the panel to generate an alarm when a door or window is opened, or when an unauthorized person enters a specific area. Disarming , speaks Motions On, and the MOTIONS button lights. 3. The panel starts an exit delay and
  • GE 600-1054-95R | User Manual - Page 19
    Chapter 2 11 Using the control panel Exit/entry delay Your Simon XT provides a delay after entering or exiting your home entry delay is the amount of time the system gives you to disarm the system after entering the home. This is programmed by the installer. When you enter your home, you will hear
  • GE 600-1054-95R | User Manual - Page 20
    12 Simon XT User Manual No entry delay Use the No Delay feature when you are staying at home, for instance when you are asleep, or when you're away from home and will carry a wireless touchpad that will allow you to disarm the system before opening a protected door. Check with your installer to find
  • GE 600-1054-95R | User Manual - Page 21
    residence after arming the system or before disarming the system upon your return. There is a communicator delay (dialer delay) of 30 seconds programmed into this panel. The panel will delay . • Make a note of the display, system beeps, and indicator lights that indicate the current system status.
  • GE 600-1054-95R | User Manual - Page 22
    14 Simon XT User Manual Light control (optional) Simon XT lets you control lights and appliances using lamp, appliance, or universal modules. You can: • Turn lights with unit numbers 1 to 8 on or off manually or at a specific time. • Turn on lights when a sensor is tripped. You can program lockout
  • GE 600-1054-95R | User Manual - Page 23
    system. When this feature is active, a latchkey alarm is reported if the premises are not disarmed by the programmed latchkey time. For example, if you set the Latchkey time for 3:00 p.m. and the system is not disarmed by that time a message is sent to your remote phone. The latchkey feature can be
  • GE 600-1054-95R | User Manual - Page 24
    16 Simon XT User Manual Using an offsite phone If enabled by the installer, you can control your Simon XT panel remotely from an offsite phone. The panel answers a phone call according to the dialing method programmed by your installer. After a certain combination of rings and pauses, the panel
  • GE 600-1054-95R | User Manual - Page 25
    Chapter 2 17 Using the control panel Using touchpads Touchpads are used to control the security system from any location within or near your home. Note: Touchpads such as the remote handheld touchpad and the keyfob, are not verified for use by UL. Remote handheld touchpad Interfacing with the system
  • GE 600-1054-95R | User Manual - Page 26
    Simon XT User Manual Keyfob If your installer programmed the keyfob with no entry delay, and you armed the system with the keyfob, you must disarm Press to disarm your security system. Star Can be programmed to control a device connected to a universal module. Light Can be programmed to control
  • GE 600-1054-95R | User Manual - Page 27
    this chapter: Status beeps 20 Alarm sirens and lamp modules 21 Panel indicator lights 22 Trouble beeps 23 AC power failure 23 System battery failure 23 Restoration of power 23 Sensor failure 23 Sensor low battery 23 Fail-to-communicate 23 Sensor open 24 Sensor tampered 24 RF jam detected
  • GE 600-1054-95R | User Manual - Page 28
    Simon XT User Manual times when the exit delay expires. Doors + Windows and Motions Disarm Exit delay and Entry delay beeps sound four times every five expires. One beep. Chime Two beeps. Special chime Three beeps. Trouble beeps Six beeps every minute. Press STATUS to stop beeps for four
  • GE 600-1054-95R | User Manual - Page 29
    the premises, each indicating a different type of alarm. Sirens are programmed by the installer to time out and stop sounding after a specified system. Table 8. Alarm Siren and X10 Light Information Function Fire Intrusion Emergency X10 lights a Steady Flashing Steady X10 siren a Steady
  • GE 600-1054-95R | User Manual - Page 30
    22 Simon XT User Manual Panel indicator lights Use Table 9 to understand the panel indicator lights. Table 9. Panel indicator lights Button DOORS+WINDOWS MOTIONS DISARM STATUS Enter Chime - Solid bell When button light is on Doors + Windows armed Motions armed System disarmed System trouble,
  • GE 600-1054-95R | User Manual - Page 31
    to call your security system dealer if the problem continues. Sensor low battery. This condition occurs if a system sensor has a low battery. The sensor may still be communicating with the panel. Trouble beeps will start and the STATUS button will light. Press the STATUS button and the display will
  • GE 600-1054-95R | User Manual - Page 32
    24 Simon XT User Manual Sensor open. This condition occurs manually. To clear system status, press the STATUS button, read and/or listen to the status messages, then press DISARM. If the trouble condition was a low system battery, perform a sensor test. The STATUS light should turn off if all trouble
  • GE 600-1054-95R | User Manual - Page 33
    describes how to program your system. It will guide you through programming instructions for system features. System menu 26 Entering and exiting the system menu 26 Code options 26 Menu navigation 27 Top-level menus 28 Set clock 28 Light schedules 29 Sensor lights 29 Chime 29 Special
  • GE 600-1054-95R | User Manual - Page 34
    26 Simon XT User Manual System menu Your Simon XT self-contained security system security system allows you to program certain user options user codes. These codes can be used for panel operations such as disarming, but not programming. These codes can be any 3, 4, 5, or 6-digit code, depending
  • GE 600-1054-95R | User Manual - Page 35
    the Enter key to save the change. Table 11. Simon XT menu structure Set clock (page 28) Light schedules (page 29) Sensor lights (page 29) Chime (page 29) Special chime (page 30) System tests (page 30) Sensor test Communication test System download System programming (page 31) Access codes (page 31
  • GE 600-1054-95R | User Manual - Page 36
    28 Simon XT User Manual Top-level menus This section explains the top-level menus, with the exception of system programming, which makes up the bulk of the menus and can be found in its own section, System programming on page 31. Set clock If the panel loses both AC and battery power, then upon
  • GE 600-1054-95R | User Manual - Page 37
    Chapter 4 29 Programming Light schedules Simon XT will automatically turn certain lights on or off according to light schedules you can define in menu item System programming / Light control / Light schedules. See Light control (optional) on page 14. To enable or disable scheduled lights: 1. Scroll
  • GE 600-1054-95R | User Manual - Page 38
    30 Simon XT User Manual Special chime To enable or disable the Special chime feature: 1. Scroll up/down until the display shows Chime. 2. Press Enter. The current setting will flash. 3.
  • GE 600-1054-95R | User Manual - Page 39
    level, the following items are accessible: • Access codes • Security • Phone #s • Timers • Siren options • Light control • System tests The sections below describe the options that you can program in the System programming menu. Access codes There are three types of access codes: master, user, and
  • GE 600-1054-95R | User Manual - Page 40
    Simon XT User Manual 5. Enter a new code (use correct length), then press Enter. 6. Press Status repeatedly to exit. Initially, all user codes are blank. A user code can be deleted by pressing Disarm system remotely. To program the Download enable option: 1. Enter the System programming menu. 2.
  • GE 600-1054-95R | User Manual - Page 41
    be deleted by pressing the DISARM button while changing a digit. part of the time now flashes. 7. Program the minute value by scrolling or entering a numerical value, then press Enter. 8. If you are using 12-hour clock format, the a or p (AM/PM) part beeps (such as trouble or chime beeps, entry
  • GE 600-1054-95R | User Manual - Page 42
    34 Simon XT User Manual 3. Scroll up/down to Piezo beeps, then press Enter. 4. The . This option determines whether or not the panel sounds alarm beeps. To program Panel piezo alarm, do the following: 1. Enter the System programming menu. 2. Scroll up/down to Siren options, then press Enter. 3.
  • GE 600-1054-95R | User Manual - Page 43
    . Light control You can control certain lights by using X10 lamp, appliance, light schedule (as defined by the unit number), then press Enter. 5. The current option value now flashes. 6. Enter the desired start time by entering the hours, minutes, and AM/PM (press Enter after programming each part
  • GE 600-1054-95R | User Manual - Page 44
    36 Simon XT User Manual Light schedules. In this menu, a light schedule can be programmed for each unit number (1 to 8). To program Light schedules, do the following: 1. Enter the System programming menu. 2. Scroll up/down to Light control, then press Enter. 3. Scroll up/down to Light schedules,
  • GE 600-1054-95R | User Manual - Page 45
    Chapter 5 Testing This chapter provides a set of tests to ensure proper operation of your Simon XT self-contained security system. We recommended you test your system weekly. Testing sensors 38 Testing communication 39 System download 40
  • GE 600-1054-95R | User Manual - Page 46
    38 Simon XT User Manual Testing sensors You can test sensors one at a time to Press STATUS once to exit the system test. If a sensor test fails, call your security dealer. Table 12. How to trip devices for sensor test Device To trip device Door/window sensor Open the secured door or window
  • GE 600-1054-95R | User Manual - Page 47
    the proper telephone connection. Note: The system must be in disarm mode. To perform a communication test: 1. Scroll to you do not have a voice report destination programmed, you won't be able to perform the unsuccessful, the STATUS button will light and within ten minutes the panel will
  • GE 600-1054-95R | User Manual - Page 48
    40 Simon XT User Manual System download You can initiate a download call to program your system with the settings specified by your installer. To initiate a download, do the following: your dealer. 9. Press STATUS twice to exit. Note: Use this feature only when instructed by your installer or dealer.
  • GE 600-1054-95R | User Manual - Page 49
    system limitations 42 Emergency planning 42 Smoke and heat detector locations 43 Your floorplan 44 Sensor and module locations 44 Access codes 46 Delays 46 Simon XT system quick reference 47
  • GE 600-1054-95R | User Manual - Page 50
    Simon XT User Manual Alarm system limitations Not even the most advanced alarm system can guarantee protection against burglary, fire, or environmental problems , or disconnecting all or part of the system. • electrical circuits, or other hazardous conditions. • If telephone lines are out of service
  • GE 600-1054-95R | User Manual - Page 51
    and reduce the chance of false alarms: • Before mounting alarms, program (learn) them into memory and do a sensor test from the any walls or partitions. • Locate wall mounted alarms so the top of the alarm is 4 to 12 in. (10 to 31 cm) below the ceiling. • In rooms with sloped, peaked, or gabled
  • GE 600-1054-95R | User Manual - Page 52
    44 Simon XT User Manual Your floorplan Use the following guidelines when drawing your floorplan: • Show all locations Sensor number Sensor name Example Front door 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Sensor type Door/window sensor Location Front door
  • GE 600-1054-95R | User Manual - Page 53
    45 Table 13. Sensor locations (continued) Sensor number Sensor name 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Table 14. X10 module locations Unit # Location 1 2 3 4 5 6 7 8 Sensor type Location Unit # 9 10 11 12 13 14 15 16 Location
  • GE 600-1054-95R | User Manual - Page 54
    46 Simon XT User Manual Access codes Table 15. Access codes Code description Master code User code 1 User code 2 User code 3 User code 4 User code 5 User code 6 User code 7 User code 8 Duress code Delays Table 16. Delays Delay Exit delay Entry delay Code Time
  • GE 600-1054-95R | User Manual - Page 55
    47 Table 17. Simon XT system quick reference a Control panel Level 0: Subdisarm Enter the master code while the the system system is disarmed. Remote touchpad Keyfob Telephone 1 Level 1: Disarm DISARM, . 1 the system Disarm Level 2: Arm doors DOORS+WINDOWS,(if
  • GE 600-1054-95R | User Manual - Page 56
    48 Simon XT User Manual
  • GE 600-1054-95R | User Manual - Page 57
    alarms 13 alarm sirens 21 alarms ...13 appliance module 2, 3 arm doors and windows 10 keyfob 2, 3, 18 B battery failure 23 bypass ...12 C carbon monoxide sensor 3 11 F fail-to-communicate 23 features ...9 fire button 7 firmware revision 30 panel controls 6 panel indicator lights
  • GE 600-1054-95R | User Manual - Page 58
    50 Simon XT User Manual programming 25 Q quick exit 12 quick reference chart 47 R remote handheld touchpad 17 restoration of power 23 revision 30 RF jam detected 24 S safety terms and symbols vii security menu 32 sensor failure 23 sensor lights 29 sensor locations 44 sensor low battery
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

g
Simon XT
User Manual
600-1054-95R