GE DCVH680GJMS Installation Instructions

GE DCVH680GJMS - 7.0 cu.ft. Gas Dryer Manual

GE DCVH680GJMS manual content summary:

  • GE DCVH680GJMS | Installation Instructions - Page 1
    semirigid or foil-type) duct is installed, it must be UL-listed and installed in accordance with the instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual. Flexible ducting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct
  • GE DCVH680GJMS | Installation Instructions - Page 2
    personal injury. Always use new flexible connectors when installing gas appliances. REMOVING LINT FROM WALL EXHAUST OPENING • Remove and discard with natural gas. Using conversion kit WE25X0217, your local service organization can convert this dryer for use with propane (LP) gas. ALL CONVERSIONS
  • GE DCVH680GJMS | Installation Instructions - Page 3
    Installation Instructions on the original installation and are not to be reused for another appliance or at another location. Keep flare end of adaptor free of grease FOR GAS LEAKS. APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET. Tighten the flexible gas line using two adjustable wrenches
  • GE DCVH680GJMS | Installation Instructions - Page 4
    Installation Instructions 5 ELECTRICAL CONNECTION INFORMATION WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, AND PERSONAL INJURY: • DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE. Dryer must be electrically grounded in accordance with local codes and ordinances, or in
  • GE DCVH680GJMS | Installation Instructions - Page 5
    flexible metal (semi-rigid or foil-type) duct to connect the dryer to the home exhaust duct. It must be installed in accordance with the instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual. • Do not terminate exhaust in a chimney, a wall, a ceiling, gas vent, crawl
  • GE DCVH680GJMS | Installation Instructions - Page 6
    Instructions, Exhausting CONNECTING THE DRYER fuel-burning appliance shall be installed in the same closet with the dryer. NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER, MINIMUM CLEARANCE HOME CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-80 or, when such standard is not
  • GE DCVH680GJMS | Installation Instructions - Page 7
    Installation Instructions 12 DRYER EXHAUST TO LEFT OR BOTTOM OF CABINET WARNING - not to pull or damage the electrical wires inside the dryer when inserting the duct. DUCT TAPE BEND TAB UP 45° Through the rear opening, locate the tab in the middle of the appliance base. Lift the tab to about
  • GE DCVH680GJMS | Installation Instructions - Page 8
    duct. • Apply duct tape on the joint between the dryer internal duct and elbow, as shown on page 7. 13 REVERSING THE DOOR SWING IMPORTANT NOTES • Read the instructions all the way through before starting. • Handle parts carefully to avoid scratching paint. • Set screws down by their related
  • GE DCVH680GJMS | Installation Instructions - Page 9
    Instructions BEFORE YOU START 1. Unplug the dryer from its electrical outlet. 4. Lay the door down on a soft protected flat surface so that the inner part starting from the bottom to the top. Make sure the door is supported while removing the screws. Remove the four screws. 2 #8 Machine Screws
  • GE DCVH680GJMS | Installation Instructions - Page 10
    Installation Instructions REMOVE HINGE IMPORTANT: Note the location of the hinge (left or right) before removing. 8. With the door frame part of the door laid down on a protected soft surface, remove the hinge cover by removing the 2 tapping screws (#8) that fasten it to the frame. The
  • GE DCVH680GJMS | Installation Instructions - Page 11
    Installation Instructions REINSTALL NUTS AND HINGE COVER 14. Place the door on its edge. Assemble the 2 machine screws (#8), washers, and nuts , there will be a mismatch between the outer door and the inner door. Make sure that the handle part of the outer door is opposite the hinge as shown. 11
  • GE DCVH680GJMS | Installation Instructions - Page 12
    on the opposite side. 14 SERVICING WARNING - LABEL ALL WIRES PRIOR TO DISCONNECTING WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER SERVICING/INSTALLATION. For replacement parts and other information, refer to Owner's Manual for servicing phone numbers. 12
  • GE DCVH680GJMS | Installation Instructions - Page 13
    ROUGH-IN DIMENSIONS 27" 27" 31 1/8" 1 5/8" 41 1/2" 4 1/2" 30 5/8" 11 3/4" 53 5/8" 40 1/4" 39 1/8" 17" 13 3/8" 11 3/4" 13
  • GE DCVH680GJMS | Installation Instructions - Page 14
    NOTES
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

Step 1
Verify Your Gas Installation (see section 2).
Step 2
Prepare the Area and Exhaust for Installation of New
Dryer (see section 1).
Step 3
Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications. (see section 6).
Step 4
Remove the Foam Shipping Pads (see section 1).
Step 5
Move the Dryer to the Desired Location.
Step 6
Level Your Dryer (see section 8).
Step 7
Connect the Gas Supply (see section 3) and check for
leaks (see section 4).
Step 8
Connect the External Exhaust (see section 7).
Step 9
Connect the Power Supply (see section 5).
Step 10
Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11
Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
If you have any questions, call 1-800-GECARES (US) or 1-800-561-3344 (Canada)
or
Visit our Web site at:
www.GEAppliances.com (US)
Installation
Instructions
Gas Dryer
10
PEDESTALS FOR DRYERS
(comes with individual installation instructions)
3 models available:
500A436P010
Pub# 31-16229
In the state of Massachusetts, installation must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified or licensed by the state.
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT-
Save these
instructions for local inspector’s use.
IMPORTANT-
Observe
all governing codes and ordinances.
Note to Installer
- Be sure to leave these
instructions with the customer.
Note to Customer
- Keep these
instructions with your Use and Care Book
for future reference.
Before the old dryer is removed from
service or discarded, remove the dryer door.
Service information and the wiring diagram
are located in the control console.
D
o not allow children on or in the appliance.
Close supervision of children is necessary
when the appliance is used near children.
Install the dryer where the temperature is
above 50°F for satisfactory operation of
the dryer control system.
Inspect the dryer exhaust outlet and
straighten the outlet walls if they are bent.
MATERIALS YOU WILL NEED
LEVEL
8" PIPE WRENCH
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
10" ADJUSTABLE WRENCHES
(x2)
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
(x2)
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
To reduce the risk of severe injury or death, follow all installation instructions.
Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance with local codes. In
the absence of local codes, installation must comply with National Fuel Gas Code,
ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
This dryer must be exhausted to the outdoors.
This act requires the governor of California to publish a list of substances known to the state to
cause cancer, birth defects or other reproductive harm and requires businesses to warn
customers of potential exposure to such substances. Gas appliances can cause minor
exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and
soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly
adjusted dryers will minimize incomplete combustion. Exposure to these substances can be
minimized further by properly venting the dryer to the outdoors.
California Safe Drinking Water and Toxic Enforcement Act
Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.
Do not install or store this appliance in any location where it could be exposed to water and or
weather.
Save these instructions. (Installers: Be sure to leave these instructions with the customer).
DO NOT install a clothes dryer with flexible plastic ducting materials.
If flexible metal (semi-
rigid or foil-type) duct is installed, it must be UL-listed and installed in accordance with the
instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual.
Flexible
ducting materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct dryer airflow and increase the risk of fire.
- RISK OF FIRE
WARNING
SBSD227F, SBSD137H
SBSD107H