    JNM3151RF GE® 1.5 cu. ft. Over-the-Range Microwave Oven with Recirculating Venting Dimensions and Installation Information (in inches) Note: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above Spacemaker microwave oven. No additional wiring, venting or cabinet
  • GE JNM3151RFSS | Quick Specs - Page 2
    . 5 ft. 24 ft. Filter Kit JX81C- Recirculating Charcoal Filter Kit To be used when the Spacemaker microwave oven cannot be vented to the outside. For answers to your Monogram® or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. Listed
  • GE JNM3151RFSS | Quick Specs - Page 3
    JNM3151RF GE® 1.5 cu. ft. Over-the-Range Microwave Oven with manually for optimal results • Turntable on/off - Controls turntable operation • Two-speed, 300-CFM venting system - Removes smoke, steam and odors • Add 30 seconds - Add 30 seconds of microwave cooking time • Model JNM3151RFSS
  • 1
  • 2
  • 3

For answers to your Monogram
®
or GE
®
appliance
questions, visit our website at geappliances.com
or call GE Answer Center
®
service, 800.626.2000.
340167
Specification Revised 7/13
Listed by
Underwriters
Laboratories
JNM3151RF
GE
®
1.5 cu. ft. Over-the-Range Microwave Oven with Recirculating Venting
Note:
Requires 120V grounded outlet. Electrical receptacle
must be located in cabinet above Spacemaker microwave oven.
No additional wiring, venting or cabinet rebuilding necessary
in many cases. Complete detailed, easy-to-follow installation
instructions and convenient full-size templates are packed with
the Spacemaker microwave oven.
Important Information:
When installing the Spacemaker
microwave oven over a range, allow minimum of 2" from bottom
of Spacemaker microwave oven to top of range backguard to
allow for removal of light covers.
Ventilation Options:
The Spacemaker microwave ovens
are designed for adaptation to the following three types of
ventilation:
• Outside exhaust (vertical – as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless – see Filter Kit drawing)
Installation Information:
This information is not intended to
be used for installing unit described. Before installing, consult
installation instructions packed with product/kit for current
dimensional data.
Dimensions and Installation Information (in inches)
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" X 10" duct
16-3/8"
(rear)
105°
Door open
(without obstruction)
15-1/4"
24-1/2
16"
29-7/8"
Minimum distance from
door hinge side to
adjacent wall should
equal 1/2 inch.
13"
MAX.
12"
MIN.