    of light covers. Ventilation Options: The Spacemaker microwave ovens are designed for adaptation to the following three types of ventilation: • Outside exhaust (vertical - as shown) • Outside exhaust (horizontal) • Recirculating (non-vented ductless - see Filter Kit drawing) Installation Information
  • GE JVM1540SPSS | Quick Specs - Page 2
    . 24 ft. For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Filter KitsJX81J- Recirculating Charcoal Filter Kit To be used when the Spacemaker microwave oven cannot be vented to the outside. Listed by
  • GE JVM1540SPSS | Quick Specs - Page 3
    JVM1540SPSS - Stainless Steel convenience cooking Popcorn Beverage Potato Reheat Time Cook Defrost Auto/Time Reminder Timer on/off Express Cook 123 456 789 Start Pause Clear Off Delay Start 0 Power Level D Add 30 Sec. Clock AM/PM S S Turn Surface Vent Table Light Fan JVM1540SMSS
  • 1
  • 2
  • 3

For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
340144
Specification Created 4/09
Listed by
Underwriters
Laboratories
JVM1540SPSS
GE Spacemaker
®
1.5 Cu. Ft. Capacity Over-the-Range Microwave
Note:
Requires 120V grounded outlet. Electrical receptacle
must be located in cabinet above Spacemaker microwave oven.
No additional wiring, venting or cabinet rebuilding necessary
in many cases. Complete detailed, easy-to-follow installation
instructions and convenient full-size templates are packed with
the Spacemaker microwave oven.
Important Information:
When installing the Spacemaker
microwave oven over a range, allow minimum of 2" from bottom
of Spacemaker microwave oven to top of range backguard to
allow for removal of light covers.
Ventilation Options:
The Spacemaker microwave ovens
are designed for adaptation to the following three types of
ventilation:
• Outside exhaust (vertical – as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless – see Filter Kit drawing)
Installation Information:
This information is not intended to
be used for installing unit described. Before installing, consult
installation instructions packed with product/kit for current
dimensional data.
Dimensions and Installation Information (in inches)
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" X 10" duct
16-7/16
(rear)
105
°
Door open
15-1/4
24-1/2
16-1/2
29-7/8
Minimum distance from
door hinge side to adjacent
wall should equal 1/2-inch.
(without
obstruction)
13"
MAX.
12"
MIN.