GE NX-591E-GSM Instruction Manual

GE NX-591E-GSM - Security NetworX Wireless Cellemetry Module Manual

GE NX-591E-GSM manual content summary:

  • GE NX-591E-GSM | Instruction Manual - Page 1
    NX-591E-GSM SMSXpress Module Installation Manual g
  • GE NX-591E-GSM | Instruction Manual - Page 2
    part or otherwise reproduced without prior written consent from GE Security except where specifically permitted under US and international copyright law. Document radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
  • GE NX-591E-GSM | Instruction Manual - Page 3
    overview 2 Website activation of new and replacement modules 2 Enrolling the module 3 Module address 3 Installation 4 Mounting 4 Wiring 5 Module LEDs 6 16 Programming worksheets 17 Specifications 24 Support 25 Contacting technical support 25 Online publication library 25 Index 27
  • GE NX-591E-GSM | Instruction Manual - Page 4
    iv NX-591E-GSM SMSXpress Module Installation Manual
  • GE NX-591E-GSM | Instruction Manual - Page 5
    is the GE NX-591E-GSM SMSXpress Module Installation Manual for model NX-591E-GSM. This document includes an overview of the product and detailed instructions explaining: • how to install; and • how to program the module. There is also information describing how to contact technical support if you
  • GE NX-591E-GSM | Instruction Manual - Page 6
    2 NX-591E-GSM SMSXpress Module Installation Manual Product overview The NX-591E-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks for event reporting. The module can be used for primary, backup, or additional
  • GE NX-591E-GSM | Instruction Manual - Page 7
    module (NX-591E-GSM). Enter the serial number of the module (located on the front of the unit). The serial number must contain 10 digits. Multiple modules can be added from this screen. Activate digital unit (direct swap). This will only activate a GSM module that is replacing an existing cellemetry
  • GE NX-591E-GSM | Instruction Manual - Page 8
    4 NX-591E-GSM SMSXpress Module Installation Manual Installation To install the module you will need to mount and wire the board. Mounting Inside the can, several two-holed insertion points have been constructed. This allows for either vertical or horizontal placement of the modules. The insertion
  • GE NX-591E-GSM | Instruction Manual - Page 9
    Length in feet 10 50 100 Wire gauge (connected to NX control panel or NX320E power supply) 20 18 16 Figure 3 shows the module wiring terminals and LEDs on the board Figure 3. Wiring terminals KP POS terminal of the panel. Refer to Specifications on page 24 for power consumption. Normally closed.
  • GE NX-591E-GSM | Instruction Manual - Page 10
    6 NX-591E-GSM SMSXpress Module Installation Manual Module LEDs The module has 14 green LEDs along the back of the board. These LEDs provide valuable information about the status of the module as described in Table 3. Table 3. Module LEDs LED DS1 DS3 DS4 DS5 DS6 XMIT POOR FAIR GOOD BEST SVC SVC2
  • GE NX-591E-GSM | Instruction Manual - Page 11
    Table 4 describes the dB signals for the LEDs. Table 4. LEDs and dB signals dB -114 -107 -106 -104 -103 -101 -100 -98 -97 -95 -94 -92 -91 -89 -88 -86 -85 -83 -82 -80 -79 -77 -76 -74 -73 Higher Poor Off Slow Fast On On On On On On On On On On Fair Off Off Off Off Slow
  • GE NX-591E-GSM | Instruction Manual - Page 12
    8 NX-591E-GSM SMSXpress Module Installation Manual Programming You can program the module using the LED keypad or the LCD keypad. To program the module using will illuminate waiting for a new programming location to be entered. To review the data, enter the location number and press #. The Armed LED
  • GE NX-591E-GSM | Instruction Manual - Page 13
    9 LCD keypad programming All steps required for programming are the same as those described for the LED keypad. The LCD keypad display will prompt you for the data required. While in programming mode, and not in a location, the number in parenthesis is the location you were previously changing. For
  • GE NX-591E-GSM | Instruction Manual - Page 14
    NX-591E-GSM SMSXpress Module Installation Manual Location 0, programming the mode This location has five numeric data segments. This location contains the system identification number (SID). Factory default is 0-0-0-0-0 for AutoSID. Note: If manually cellular service LEDs may not support the use of
  • GE NX-591E-GSM | Instruction Manual - Page 15
    Short circuit and ground fault Sensor lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for future use. Location 3, special events to report to central station Phone fault detected. This location has 8 segments. This location selects the partitions
  • GE NX-591E-GSM | Instruction Manual - Page 16
    12 NX-591E-GSM SMSXpress Module Installation Manual Location 4, events to report to e-mail Phone fault detected. This location has battery Expander trouble Failure to communicate Zone activity monitor Reserved for future use. Location 5, special events to report to e-mail Phone fault detected.
  • GE NX-591E-GSM | Instruction Manual - Page 17
    Tampers Short circuit and ground fault Sensor lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for future use. Location 7, special events to report to pager Phone fault detected. This location has 8 segments. This location selects the partitions to
  • GE NX-591E-GSM | Instruction Manual - Page 18
    14 NX-591E-GSM SMSXpress Module Installation Manual Location 8, events to report to central station Phone line is good. This location battery Expander trouble Failure to communicate Zone activity monitor Reserved for future use. Location 9, special events to report to central station Phone line
  • GE NX-591E-GSM | Instruction Manual - Page 19
    15 Location 10, events to report to e-mail Phone line is good. This location has 16 segments. Note: lost Sensor low battery Expander trouble Failure to communicate Zone activity monitor Reserved for future use. Location 11, special events to report to e-mail Phone line is good. This location
  • GE NX-591E-GSM | Instruction Manual - Page 20
    16 NX-591E-GSM SMSXpress Module Installation Manual Location 12, events to report to pager Phone line is good. This location has 16 low battery Expander trouble Failure to communicate Zone activity monitor Reserved for future use. Location 13, special events to report to pager Phone line is good
  • GE NX-591E-GSM | Instruction Manual - Page 21
    ) Off 3 = System preference (off = no preference) Off 4 = B side preference (off = A side) Off 5 = Disable alternate MIN Off 6 = Disable cellular service LEDs Off 7 = Enable tamper switch Off 8 = Disable SIA DCS area modifier Off 2, Host 1 = Host acknowledgement for central station
  • GE NX-591E-GSM | Instruction Manual - Page 22
    18 NX-591E-GSM SMSXpress Module Installation Manual Location 2, Reporting events to central station (Phone line fault detected) Table 20. Location 2 worksheet Partition Segment 1 2 3 4 5 6 7 8 Description 1 Alarms 2 Open/close 3 Bypass 4 Zone trouble 5 Power trouble (AC fail or low
  • GE NX-591E-GSM | Instruction Manual - Page 23
    circuit and ground fault 11 Sensor lost 12 Sensor low battery 13 Expander trouble 14 Fail to communicate 15 Zone activity monitor 16 Reserved for future use. Location 5, Reporting special events to e-mail (Phone line fault detected) Table 23. Location 5 worksheet Partition Segment
  • GE NX-591E-GSM | Instruction Manual - Page 24
    20 NX-591E-GSM SMSXpress Module Installation Manual Location 6, Reporting events to pager (Phone line fault detected) Table 24. Location 6 worksheet Partition Segment 1 2 3 4 5 6 7 8 Description 1 Alarms 2 Open/close 3 Bypass 4 Zone trouble 5 Power trouble (AC fail or low battery) 6
  • GE NX-591E-GSM | Instruction Manual - Page 25
    circuit and ground fault 11 Sensor lost 12 Sensor low battery 13 Expander trouble 14 Fail to communicate 15 Zone activity monitor 16 Reserved for future use. Location 9, Reporting special events to central station (Phone line is good) Table 27. Location 9 worksheet Partition Segment
  • GE NX-591E-GSM | Instruction Manual - Page 26
    22 NX-591E-GSM SMSXpress Module Installation Manual Location 10, Reporting events to e-mail (Phone line is good) Table 28. Location 10 worksheet Partition Segment 1 2 3 4 5 6 7 8 Description 1 Alarms 2 Open/close 3 Bypass 4 Zone trouble 5 Power trouble (AC fail or low battery) 6
  • GE NX-591E-GSM | Instruction Manual - Page 27
    10 Short circuit and ground fault 11 Sensor lost 12 Sensor low battery 13 Expander trouble 14 Fail to communicate 15 Zone activity monitor 16 Reserved for future use. Location 13, Reporting special events to pager (Phone line is good) Table 31. Location 13 worksheet Partition Segment
  • GE NX-591E-GSM | Instruction Manual - Page 28
    24 NX-591E-GSM SMSXpress Module Installation Manual Specifications Operating power Power consumption 12 VDC supplied from NX control panel or NX-320E power supply Standby with service LEDs disabled 70 mA max. Standby with service LEDs enabled 90 mA max. Transmission burst (
  • GE NX-591E-GSM | Instruction Manual - Page 29
    Table 32. Sales and support contact information Sales Technical support Phone: Toll-free: 888.GESECURity (888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada). Outside the toll-free area: 503.885.5700. E-mail [email protected] [email protected] Fax 888
  • GE NX-591E-GSM | Instruction Manual - Page 30
    26 NX-591E-GSM SMSXpress Module Installation Manual
  • GE NX-591E-GSM | Instruction Manual - Page 31
    exit mode 8 F factory default 8 I installation 4 L LED ...5, 6 location programming 8 M module address 3 mounting 4 P preface ...1 product overview publication library 25 S safety terms and symbols 1 T technical support 25 troubleshooting 25 W web activation 2 wire gauge 5 wiring ...5
  • GE NX-591E-GSM | Instruction Manual - Page 32
    28 NX-591E-GSM SMSXpress Module Installation Manual
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

g
NX-591E-GSM SMSXpress Module
Installation Manual