Gigabyte GA-M61PME-S2P Manual - Page 68

Free Disks, Array Disks

Page 68 highlights

Step 5: Next, select the hard drives which you wish to be included in the disk array. The Free Disks block displays the information about the SATA hard drives that are available for use as RAID array drives. Press to move to the Free Disks block. Select the target hard drives using the up or down arrow key and use the right arrow key to add the hard drives to the Array Disks block (Figure 5). RAID Mode: Striping MediaShield Utility Nov 20 2006 - Define a New Array - Striping Block: Optimal Free Disks Port Disk Model Capacity Array Disks Port Disk Model 1.0 [] Add 1.1 ST3120026AS ST3120026AS Capacity 111.79GB 111.79GB [] Del [ESC] Quit [F6] Back [F7] Finish [TAB] Navigate [] Select [ENTER] Popup Figure 5 Step 6: After assigning the RAID drives, press . A message which says "Clear disk data?" appears (Figure 6). Press to confirm or press to cancel. (If the hard drives contain a previously created RAID array, you need to press to clear the data in the hard drives.) RAID Mode: Striping MediaShield Utility Nov 20 2006 - Define a New Array - Striping Block: Optimal Free Disks Port Disk Model Capacity Clear disk data?Array Disks Port Disk Model [Y] YCElSear d[Nisk] NdaO1ta.0?.M ST3120026AS [] Add 1.1.M ST3120026AS [Y] YES [N] NO [] Del Capacity 111.79GB 111.79GB [ESC] Quit [F6] Back [F7] Finish [TAB] Navigate [] Select [ENTER] Popup Figure 6 GA-M61PME-S2P Motherboard - 68 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

GA-M61PME-S2P Motherboard
- 68 -
Step 6:
After assigning the RAID drives, press <F7>. A message which says "Clear disk data?" appears
(Figure 6). Press <Y> to confirm or press <N> to cancel. (If the hard drives contain a previously created
RAID array, you need to press <Y> to clear the data in the hard drives.)
Figure 6
Figure 5
Step 5:
Next, select the hard drives which you wish to be included in the disk array. The
Free Disks
block
displays the information about the SATA hard drives that are available for use as RAID array drives.
Press <Tab> to move to the
Free Disks
block. Select the target hard drives using the up or down arrow
key and use the right arrow key to add the hard drives to the
Array Disks
block (Figure 5).
MediaShield Utility
Nov 20 2006
- Define a New Array -
RAID Mode:
Striping
Striping Block:
Optimal
[
] Add
[
] Del
[ESC] Quit
[F6] Back
[F7] Finish
[TAB] Navigate
[





] Select
[ENTER] Popup
1.0
ST3120026AS
111.79GB
1.1
ST3120026AS
111.79GB
Free Disks
Port
Disk
Model
Capacity
Array Disks
Port
Disk
Model
Capacity
RAID Mode:
Striping
Striping Block:
Optimal
[
] Del
[ESC] Quit
[F6] Back
[F7] Finish
[TAB] Navigate
[





] Select
[ENTER] Popup
ST3120026AS
111.79GB
ST3120026AS
111.79GB
MediaShield Utility
Nov 20 2006
- Define a New Array -
Model
Capacity
Free Disks
Port
Disk
Model
Clear disk data?
[Y] YES
[N] NO