Haier 3HUM20H03 User Manual

Haier 3HUM20H03 Manual

Haier 3HUM20H03 manual content summary:

  • Haier 3HUM20H03 | User Manual - Page 1
    FLOOR UNIT ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner. No.0010509578
  • Haier 3HUM20H03 | User Manual - Page 2
    and address of the waste materials collecting centers and waste paper disposal services nearest to your house. Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes
  • Haier 3HUM20H03 | User Manual - Page 3
    air conditioner.In no case should children be allowed to sit on the outdoor unit. Specifications The refrigerating it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the that they do not play with the appliance. 9. A breaker should be incorporated into
  • Haier 3HUM20H03 | User Manual - Page 4
    of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire
  • Haier 3HUM20H03 | User Manual - Page 5
    yourself. PROHIBITION PROHIBITION CAUTION Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with food, art work, precise equipment, when gas appliance is running at the wet hand. breeding, or cultivation. same time. PROHIBITION Do not
  • Haier 3HUM20H03 | User Manual - Page 6
    Parts and Functions Indoor unit 1.OUTLET 2.CONTROL PANEL 3.INLET 4.FILTER (inside) 5.OUTLET Outdoor unit OUTLET INLET CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE 5
  • Haier 3HUM20H03 | User Manual - Page 7
    remote controller is not available. Air outlet selection Indoor temperature sensor Senses the air temperature around the unit. Air flow selection Make air flow selection according to what suits you. When setting the air flow selection switch to Air conditioner automatically decides the appropriate
  • Haier 3HUM20H03 | User Manual - Page 8
    Used to select AUTO, COOL, DRY, FAN and HEAT operation. 5. ON/OFF Used for unit start and stop. 6. SWING Used to adjust the up/down air flow direction. 7. TEMP. Used to select your desired temperature. 8. TIMER ON display 9. SLEEP display 10. FAN SPEED display Remote controller: LOW MED HI AUTO
  • Haier 3HUM20H03 | User Manual - Page 9
    Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: 1. Press CLOCK button,"AM" or "PM" flashes. 2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is
  • Haier 3HUM20H03 | User Manual - Page 10
    button. For each press, fan speed changes as follows: Remote controller: LOW MED HI AUTO Air conditioner is running under displayed wind speed When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 5.Unit stop Press ON/OFF button, the
  • Haier 3HUM20H03 | User Manual - Page 11
    button. For each press, fan speed changes as follows: Remote controller: LOW MED HI AUTO Air conditioner is running under displayed wind speed When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 5.Unit stop Press ON/OFF button, the
  • Haier 3HUM20H03 | User Manual - Page 12
    press, fan speed changes as follows: Remote controller: LOW MED HI AUTO COOL operation starts when room temp.is higher than temp.setting. Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes lower than temp.setting+2oC,unit will run intermittently at
  • Haier 3HUM20H03 | User Manual - Page 13
    Operation FAN Operation Remote controller 1. Unit start Press ON/OFF on the indoor unit, or press ON/OFFon the remote controller, unit starts. Previous operation status appears on LCD display (no timer and sleep). 2.Select operation mode Press MODE button. For each press, operation mode changes as
  • Haier 3HUM20H03 | User Manual - Page 14
    speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED HI AUTO Air conditioner is running under displayed wind speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set
  • Haier 3HUM20H03 | User Manual - Page 15
    . CAUTION Do not try to adjust the flap by hand. When adjusting by hand, the mechanism may not operate properly or condensation may drip from air outlets ATTENTION When adjusting the flap by hand, turn off the unit, and use the remote controller to restart the unit. Adjusting the louver Hold
  • Haier 3HUM20H03 | User Manual - Page 16
    button to adjust the detail sleep time. 6. If the sleep time in cooling, dehumidifying and heating run is less than 8 hours SLEEP operation starts SLEEP operation stops Approx. 2 hrs Within the set sleep time, the conditioner will run as per the procedure described in 1 and 2. It will be
  • Haier 3HUM20H03 | User Manual - Page 17
    Operation Timer On/Off Operation Remote controller Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode. Operation mode will be displayed on LCD 2. Timer mode selection Press TMIER button to change TIMER mode. Every time' the button pressed,
  • Haier 3HUM20H03 | User Manual - Page 18
    Operation TIMER On-Off Operation Remote Controller Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is
  • Haier 3HUM20H03 | User Manual - Page 19
    Operation POWER/SOFT Operation POWER Operation When you need rapid heating or cooling, you can use this funciton. Selecting of POWER operation Press POWER/SOFT button. Every time the button is pressed,display changes as follows: BLANK POWER SOFT Stop the display at In POWER operation status:
  • Haier 3HUM20H03 | User Manual - Page 20
    for more than 5 seconds. After you hear the "BI" sound twice, release your finger from the switch, the test operation starts and the air conditioner starts with the air flow speed setting "Hi". ON/OFF TEST SWITCH Unit stop(to cancel test operation) Push the test run switch or operate with remote
  • Haier 3HUM20H03 | User Manual - Page 21
    computer management or remote monitoring of the conditioner. Please refer to the manual of the " Conditioner remote control detector" for the details failure happens during unit operation in power failure resume mode,if the air conditioner is not desired for use in a long period, please shut off
  • Haier 3HUM20H03 | User Manual - Page 22
    of the unit Turn off the power switch Do not touch with wet hand Do not clean with hot water or solvent Take off the air inlet grill First switch off the power supply, take off the screw cap, loosen the screw with cross screwdriver. Clean the filter Use water or
  • Haier 3HUM20H03 | User Manual - Page 23
    the units well. Maintenance before beginning of application season Check there are no obstacles in the air inlet and outlet to avoid impairing of working efficiency. Please do attach the air filter to ensure the electrostatic filters not soiled. Otherwise,dirt will come into and damage the unit
  • Haier 3HUM20H03 | User Manual - Page 24
    Trouble shooting Before asking for service, check the following first. Phenomenon The system air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Please read this operation manual before using the air conditioner.
No.0010509578
FLOOR UNIT ROOM AIR CONDITIONER
OPERATION MANUAL