Haier AB182ACAEA User Manual

Haier AB182ACAEA Manual

Haier AB182ACAEA manual content summary:

  • Haier AB182ACAEA | User Manual - Page 1
    CASSETTE TYPE AIR CONDITIONER Operation & Installation Manual AB182ACAEA AB282ACAEA AB42NACAEA No.0010575661 Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
  • Haier AB182ACAEA | User Manual - Page 2
    Contents Cautions 1-5 Introduction to Spare Parts 6 Maintenance 7-12 Trouble Shooting 13-14 When Trouble Happens 15-16 Customer Need-to-know 17 Installation Procedure 18-28
  • Haier AB182ACAEA | User Manual - Page 3
    and waste paper disposal services nearest to your house. conditioner in order to avoid the risk of child entrapment. Safety Instructions and Warnings Before starting the air conditioner, read the It must be noticed that air conditioner system contains refrigerants, which require specialized waste
  • Haier AB182ACAEA | User Manual - Page 4
    the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes supply cord is damaged, it must be replaced by the manufacturer or its service agentor a similar qualified person. 3. If the fuse on PC board is broken please
  • Haier AB182ACAEA | User Manual - Page 5
    conditioner is transferred to the new user, this manual should be as well transferred to the new user. WARNING! Don't blow the human body with the cooling air . Call the dealer to take measures to prevent the refrigerant from leaking. If conditioner is installed in a small room be sure to take
  • Haier AB182ACAEA | User Manual - Page 6
    with other heat-radiator the frequent replacement of room atmosphere should be required. Inefficient ventilation may cause suffocation. After a long time use of air-conditioner the base should be checked for any damages. If the damaged base is not repaired, the unit may fall down and cause accidents
  • Haier AB182ACAEA | User Manual - Page 7
    -magnetic waves. (h) Places with acid, alkali vapuor. TV, radio, acoustic appliances etc are at least 1 m far away to the indoor unit, outdoor unit Operating noise] Chose the following locations: (a) Capable of supporting air-conditioner weight, don't increase operating noise and vibration. (b)
  • Haier AB182ACAEA | User Manual - Page 8
    cooling operation, to discharge the water from inside the room. Outlet Air filter (located in the suction grill) Suction grill AB42NACAEA Discharge unit room. Outlet Air filter (located in the suction grill) Suction grill 6 Drain Hose Swing fender (located in the outlet) Refrigerant pipe Cable
  • Haier AB182ACAEA | User Manual - Page 9
    blots are opened for inlet grille easily up and down as well cheaning the air filter.After open it,lower the inlet grille using remote controller, the maximum 1 rotated clamps 90 degree as shown in the figure, hold the air filter and nearly in the horizontal direction slightly pull it out. Fixing
  • Haier AB182ACAEA | User Manual - Page 10
    1. Open inlet grill Press the elliptical "PUSH" knob, the inlet grill will automatically drop. (the inlet grill is catched with two pothooks) 5. Install air filter (1) Put filter into protruding parts at the top of the inlet grill. (2) Connect the two pothooks with inlet grill Press the elliptical
  • Haier AB182ACAEA | User Manual - Page 11
    When the filter too much dust To spray the special detergent for vent fan or utensils. 5. Install inlet grill see 3 6. Install air filter see "Clean air filter" 7. Close inlet grill see 1 [Clean outlet and shell] CAUTION! Don't use gasoline, benzene, dilutant, polishing powder, or liquid inseticide
  • Haier AB182ACAEA | User Manual - Page 12
    AB42NACAEA Clean the air filter Instructions : When not for cleaning, do not dismantle the air filter, otherwise it may cause trouble. When the air conditioner is used in a dusty environment, the air filter should be cleaned more often (generally once every two weeks). Open 1. Open air inlet grille
  • Haier AB182ACAEA | User Manual - Page 13
    or deformation. Open Use soft brush, water and neutral detergent to clean, then throw the water off. Instruction [ When there is too much dust ] Use ventilation fan or directly spray the detergent special for kitchen ware on the air inlet grille, 10 minutes later use water to clean. 5. Install
  • Haier AB182ACAEA | User Manual - Page 14
    to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat. Pre-season Care See that there is no obstacles blocking
  • Haier AB182ACAEA | User Manual - Page 15
    conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction. Cracking sound is heard It smells. During operation, white fog comes out
  • Haier AB182ACAEA | User Manual - Page 16
    Trouble Shooting Air does not blow or the fan speed cannot be changed during drying. running for a while after unit automatically stops. Please check the following things about your air conditioner before making a service call. Is the power supply switch on ? Unit fails to start. Is city supply
  • Haier AB182ACAEA | User Manual - Page 17
    Trouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEAT mode) Any obstacle exists at the air is observed,stop the operation of the air conditioner and contact your sales dealer. 1)The
  • Haier AB182ACAEA | User Manual - Page 18
    When Trouble Happens Failure description Room temp. sensor abnormal Indoor coil temp. sensor abnormal Over-current malfunction Drainage system malfunction Flash times of indoor receiver board Power
  • Haier AB182ACAEA | User Manual - Page 19
    air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual : after finishing installation,confirm no refrigerant leakage. 17
  • Haier AB182ACAEA | User Manual - Page 20
    Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 11. Band tape 12. Scraper 13. Refrigerant oil Standard accessories The following parts mentioned in this manual are the installation accessories we prepared. Symbol Parts Name A Adhesive tape B Pipe clamp C Connecting hose
  • Haier AB182ACAEA | User Manual - Page 21
    done by experienced people as per eocal code, regulations and this Manual. Use exclusive wire for the unit. Incorrect installation or undersized electric . Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas when meet heat source as heater, oven, etc
  • Haier AB182ACAEA | User Manual - Page 22
    be ensured. No block to air flow. Water drainage is smpoth. Place strong enough to support unit weight. Place where inclination is not evident on ceiling. Enough space for mainenance. Indoor and outdoor unit piping length is within limit. (Refer to Installation Manual for outdoor unit.) Indoor and
  • Haier AB182ACAEA | User Manual - Page 23
    to paper pattern for dimension of ceiling hole. Connect all pipings (refrigerant, water drainage), wirings (inter unit cable) to indoor unit, before real estate dealer (3) Install a suspending bolt. (Use a M10 bolt) To support the unit weight, anchor bolt shall be used in the case of already exists
  • Haier AB182ACAEA | User Manual - Page 24
    horizontal compartor or PVC tube with water. (If unit is tilting against the direction of water drainage, problem may occur on floating switch, causing water leakage.) (5) Remove the washer mounlting 2 , and tighten the nut above. (6) Remove the paper pattern. Nut (Prepare in feild) In the case
  • Haier AB182ACAEA | User Manual - Page 25
    Manual of outdoor unit.) Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to Table 1. Apply refrigerant slope at least 1/100 to prevent air bag from happening. If downward slope can
  • Haier AB182ACAEA | User Manual - Page 26
    Installation Procedure For: AB182ACAEA Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the ornament panel. Fasten the screws to make the height
  • Haier AB182ACAEA | User Manual - Page 27
    100mm Watering can of plastic pipe should be about 100 mm long Charge water from inspecting hole Charge water from air outlet Cover of controll box For :AB282ACAEA Y/G INDOOR UNIT 1 2 3 TERMINIAL BLOCK W B R Y/G L N 1 2 3 Y/G W B Y/G Y/G W B R Y/G POWER SUPPLY: 1PH, 220-230V~, 50Hz For
  • Haier AB182ACAEA | User Manual - Page 28
    in appliance with Manual and guide them how to operate unit correctly. Before installation. read also the Installation Manual of indoor unit. With this ornament , 2 or 3 air Don' t bend carelessly the swing flap, or, problem may occur. (1) Remove air inlet grill from ornament panel * 1 Push in
  • Haier AB182ACAEA | User Manual - Page 29
    panel on indoor unit. For indoor unit installation, please refer to Installation Manual. (1) As shown in Fig . 7, match the position of swing flap unit Ceiling material Seal 5 _ 8mm If screws are not tighten tight, problems in Fig, 8 might occur. Tighten screws properly. Gas leakage. Gas leakage
  • Haier AB182ACAEA | User Manual - Page 30
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Please read this operation manual before using the air conditioner.
No.0010575661
Operation & Installation
Manual
AB182ACAEA
AB282ACAEA
AB42NACAEA
CASSETTE
TYPE AIR
CONDITIONER
Please keep this manual carefully and safely.