Haier AB182ACERA User Manual

Haier AB182ACERA Manual

Haier AB182ACERA manual content summary:

  • Haier AB182ACERA | User Manual - Page 1
    CASSETTE TYPE AIR CONDITIONER DC INVERTER Operation & Installation Manual AB092ACERA AB142ACERA AB182ACERA Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely. * No.0010576955 A
  • Haier AB182ACERA | User Manual - Page 2
    Contents Cautions 1-2 Main Points of Operation 3-4 Name of Each Part 5 Safety Cautions 6-7 Maintenance 8-9 When Trouble Happens 10 Customer Need-to-know 11 Installation Tools 12 Installation Procedures 13-20 Trouble Shooting 21-23 Installation Procedures,Check and Test Run 24
  • Haier AB182ACERA | User Manual - Page 3
    waste materials collecting centers and waste paper disposal services nearest to your house. Safety Instructions and Warnings Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly
  • Haier AB182ACERA | User Manual - Page 4
    of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with indoor unit installation height is at least 2.5m. 8. The appliance must be installation that the plug should be easily accessible after
  • Haier AB182ACERA | User Manual - Page 5
    interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a faraway place. 3
  • Haier AB182ACERA | User Manual - Page 6
    Failure Compensation(to be applied for a necessary situation): After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again. Setting Method: When the remote controller is
  • Haier AB182ACERA | User Manual - Page 7
    of Each Part Indoor unit Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller) Operating Control Panel Air Inlet Grille Air Filter (Inside of the Inlet Grille) outdoor unit Air inlet Connecting piping and electrical wiring Air outlet Drain hose 5
  • Haier AB182ACERA | User Manual - Page 8
    damages or endanger the userípersonal safety. INSTRUCTION: This information can ensure the correct time when needed. If the air conditoner is transferred to the new user, this manual should be as well transferred even in case of refrigerant leakage When air conditioner is removed and reinstalled
  • Haier AB182ACERA | User Manual - Page 9
    ,which may cause incomplete combustion No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident. Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt. Not permitted when running
  • Haier AB182ACERA | User Manual - Page 10
    filter with water or vacuum cleaner. Use the detergent or neutral soapy water if the air filter is too dirty. Then rinse the air filter with water,and reinstall after drying. Caution: Do not clean the air filter with hot water over 40 C, otherwise may damage the filter. Sweep the filter carefully
  • Haier AB182ACERA | User Manual - Page 11
    to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat. Pre-season Care See that there is no obstacle blocking
  • Haier AB182ACERA | User Manual - Page 12
    Trouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEAT mode) Any obstacle exists at the air is observed,stop the operation of the air conditioner and contact your sales dealer. The fuse
  • Haier AB182ACERA | User Manual - Page 13
    air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual finishing installation, please confirm no refrigerant leakage. 11
  • Haier AB182ACERA | User Manual - Page 14
    7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 11. Band tape 12. Scraper 13. Refrigerant oil The following parts mentioned in this manual are the installation accessories we prepared. Symbol Parts Name A Adhesive tape B Pipe clamp C Connecting hose D Drainage
  • Haier AB182ACERA | User Manual - Page 15
    Unit Selection of installation place Place strong enough to support unit weight, and will not cause vibration and noise affected by rain or direct sunlight and sea breeze. Place with enough space for smooth air flow. The unit cannot be installed on an unspecified metal frame (e.g. theft guard net).
  • Haier AB182ACERA | User Manual - Page 16
    pipe can be arranged well. (3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked. (4) ) concentrates and retains. (6) Place strong enough to support the unit weight. (7) No expensive articles such as panel (2) Prepare all piping (refrigerant,water drainage )and wires (
  • Haier AB182ACERA | User Manual - Page 17
    Installation Procedures (3) Install a suspending bolt To support the unit weight ,anchor bolt should be against the direction of water drainage,problem may occur on floating water leakage.) Nut (Prepare in feild) In the case of ceiling already exists Washer (Prepared in feild) (1)Install unit
  • Haier AB182ACERA | User Manual - Page 18
    than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm ) Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming. If downward slope of drainpipe cannot be made,lifting pipe shall be installed. Keep a distance of 1-1.5m between suspending bolts
  • Haier AB182ACERA | User Manual - Page 19
    Installation Procedures 6. Installation of Ornament Panel Install ornament panel on indoor unit (1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the
  • Haier AB182ACERA | User Manual - Page 20
    . Both gas pipe and liquid pipe shall be heat insulation. No leakage in the flare. Spanner Spanner Joint Nut (3) Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare. The bending radius shall be as large as possible. Align the pipe center when fastening, and
  • Haier AB182ACERA | User Manual - Page 21
    . CAUTION: If the refrigerant of the air conditioner leaks, it is necessary to make all the refrigerant out, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate. 2-way valve 3-way valve 7 Valve rod cap 7 Valve rod cap 7 Service port cap 19
  • Haier AB182ACERA | User Manual - Page 22
    N 1 23 Outdoor unit terminal block Power supply:1PH,220-230V~,50Hz 2.Installation of drain elbow Installation of drain elbow.(Only for heat pump type air conditioner, no drain elbow for single cooling type).If use drain elbow,please install as shown in the figure. Do not use drain elbow in cold
  • Haier AB182ACERA | User Manual - Page 23
    conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction. Cracking sound is heard It smells. During operation, white fog comes out
  • Haier AB182ACERA | User Manual - Page 24
    Trouble Shooting Air does not blow or the fan speed cannot be changed during drying. running for a while after unit automatically stops. Please check the following things about your air conditioner before making a service call. Is the power supply switch on ? Unit fails to start. Is city supply
  • Haier AB182ACERA | User Manual - Page 25
    Trouble Shooting 23 For remote Failure description type, flash times Reason Remarks 1 Indoor ambient temp. sensor failure Sensor broken down or short circuit for more than
  • Haier AB182ACERA | User Manual - Page 26
    Procedures,Check and Test Run Other Instructions 1.Configuration of power supply Air conditioner must use special power supply system outward Installation check and test run Require customers to use air conditioner according to the operation manual. The items checked during test run,please mark in
  • Haier AB182ACERA | User Manual - Page 27
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

No.0010576955 A
CASSETTE TYPE AIR CONDITIONER
DC INVERTER
Operation & Installation
Manual
AB092ACERA
AB142ACERA
AB182ACERA
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
*