  • Haier AB212XCEAA | User Manual - Page 1
    CASSETTE TYPE AIR CONDITIONER Operation & Installation Manual AB212XCEAA No.0010577706 Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
  • Haier AB212XCEAA | User Manual - Page 2
    Contents Cautions 1-4 Introduction to Spare Parts 5 Maintenance 6-8 Trouble Shooting 9-10 When Trouble Happens 11 Customer Need-to-know 12 Installation Procedure 13-24 Failure Code 25
  • Haier AB212XCEAA | User Manual - Page 3
    and waste paper disposal services nearest to your house. conditioner in order to avoid the risk of child entrapment. Safety Instructions and Warnings Before starting the air conditioner, read the It must be noticed that air conditioner system contains refrigerants, which require specialized waste
  • Haier AB212XCEAA | User Manual - Page 4
    air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner is at least 2m. 9. The appliance is not intended for ase young children replaced by the manufacturer or its service agent or a similar qualified person. 3. If the
  • Haier AB212XCEAA | User Manual - Page 5
    conditioner is transferred to the new user, this manual should be as well transferred to the new user. WARNING! Don't blow the human body with the cooling air . Call the dealer to take measures to prevent the refrigerant from leaking. If conditioner is installed in a small room be sure to take
  • Haier AB212XCEAA | User Manual - Page 6
    with other heat-radiator the frequent replacement of room atmosphere should be required. Inefficient ventilation may cause suffocation. After a long time use of air-conditioner the base should be checked for any damages. If the damaged base is not repaired, the unit may fall down and cause accidents
  • Haier AB212XCEAA | User Manual - Page 7
    Introduction to Spare Parts Discharge unit (built in) In cooling operation, to discharge the water from inside the room. Outlet Air filter (located in the suction grill) Suction grill Drain Hose Swing fender (located in the outlet) Refrigerant pipe Cable line Earthing line 5
  • Haier AB212XCEAA | User Manual - Page 8
    1. Open inlet grill Press the elliptical "PUSH" knob, the inlet grill will automatically drop. (the inlet grill is catched with two pothooks) 5. Install air filter (1) Put filter into protruding parts at the top of the inlet grill. (2) Connect the two pothooks with inlet grill Press the elliptical
  • Haier AB212XCEAA | User Manual - Page 9
    When the filter too much dust To spray the special detergent for vent fan or utensils. 5. Install inlet grill see 3 6. Install air filter see "Clean air filter" 7. Close inlet grill see 1 [Clean outlet and shell] CAUTION! Don't use gasoline, benzene, dilutant, polishing powder, or liquid inseticide
  • Haier AB212XCEAA | User Manual - Page 10
    to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat. Pre-season Care See that there is no obstacles blocking
  • Haier AB212XCEAA | User Manual - Page 11
    conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction. Cracking sound is heard It smells. During operation, white fog comes out
  • Haier AB212XCEAA | User Manual - Page 12
    Trouble Shooting Air does not blow or the fan speed cannot be changed during drying. running for a while after unit automatically stops. Please check the following things about your air conditioner before making a service call. Is the power supply switch on ? **? Unit fails to start. Is city
  • Haier AB212XCEAA | User Manual - Page 13
    Trouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEAT mode) Any obstacle exists at the air is observed,stop the operation of the air conditioner and contact your sales dealer. 1)The
  • Haier AB212XCEAA | User Manual - Page 14
    air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual : after finishing installation,confirm no refrigerant leakage. 12
  • Haier AB212XCEAA | User Manual - Page 15
    -magnetic waves. (h) Places with acid, alkali vapuor. TV, radio, acoustic appliances etc are at least 1 m far away to the indoor unit, outdoor unit Operating noise] Chose the following locations: (a) Capable of supporting air-conditioner weight, don't increase operating noise and vibration. (b)
  • Haier AB212XCEAA | User Manual - Page 16
    done by experienced people as per eocal code, regulations and this Manual. Use exclusive wire for the unit. Incorrect installation or undersized electric . Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas when meet heat source as heater, oven, etc
  • Haier AB212XCEAA | User Manual - Page 17
    12. Scraper 13. Refrigerant oil 1. BEFORE INSTALLATION air flow. Water drainage is smpoth. Place strong enough to support unit weight. Place where inclination is not evident on ceiling. Enough space for mainenance. Indoor and outdoor unit piping length is within limit. (Refer to Installation Manual
  • Haier AB212XCEAA | User Manual - Page 18
    to paper pattern for dimension of ceiling hole. Connect all pipings (refrigerant, water drainage), wirings (inter unit cable) to indoor unit, before real estate dealer (3) Install a suspending bolt. (Use a M10 bolt) To support the unit weight, anchor bolt shall be used in the case of already exists
  • Haier AB212XCEAA | User Manual - Page 19
    horizontal compartor or PVC tube with water. (If unit is tilting against the direction of water drainage, problem may occur on floating switch, causing water leakage.) (5) Remove the washer mounlting 2 , and tighten the nut above. (6) Remove the paper pattern. Nut (Prepare in feild) In the case
  • Haier AB212XCEAA | User Manual - Page 20
    Manual of outdoor unit.) Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to Table 1. Apply refrigerant slope at least 1/100 to prevent air bag from happening. If downward slope can
  • Haier AB212XCEAA | User Manual - Page 21
    Installation Procedure (2) Check if water drainage is smooth after installation. Charge, through air outlet or inspecting hole, 1200ccd water to see water drainage. After wiring Check water drainage in cooling operation. When wiring is not complete Remove cover
  • Haier AB212XCEAA | User Manual - Page 22
    in appliance with Manual and guide them how to operate unit correctly. Before installation. read also the Installation Manual of indoor unit. With this ornament , 2 or 3 air Don' t bend carelessly the swing flap, or, problem may occur. (1) Remove air inlet grill from ornament panel * 1 Push in
  • Haier AB212XCEAA | User Manual - Page 23
    panel on indoor unit. For indoor unit installation, please refer to Installation Manual. (1) As shown in Fig . 7, match the position of swing flap unit Ceiling material Seal 5 _ 8mm If screws are not tighten tight, problems in Fig, 8 might occur. Tighten screws properly. Gas leakage. Gas leakage
  • Haier AB212XCEAA | User Manual - Page 24
    correctly arranged? Is unit safely grounded? Is wire size correct? Are there any obstacles on air inlet and outlet grill of indoor and outdoor unit? Is record made for piping length and refrigerant charging amount? Unproper installation may cause Unit might fall down, make vibration or noise. This
  • Haier AB212XCEAA | User Manual - Page 25
    service center or similar personnel to avoid risks. The power supply to the indoor unit shall be laid in complying with the operational instruction manual control wiring and refrigerant piping may be laid and fastened together. Before completion of vacuum pumping of the refrigerant pipe system, do
  • Haier AB212XCEAA | User Manual - Page 26
    Signal cable H05RN-F 3G (1.0~1.5)mm2 H05RN-F 2x(0.75~1.5)mm2 All the cables shall have got the European authentication certificate. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be
  • Haier AB212XCEAA | User Manual - Page 27
    Failure code The remote receiver can indicate the failure code For Failure For Failure description Reason remote code on central type, wired control, flash control failure times ler code 10 08 21 Drainage system failure Float switch broken down for more than 25m continuously 1 01 01
  • Haier AB212XCEAA | User Manual - Page 28
    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P.R.C Web Site: http://www.haier.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Please read this operation manual before using the air conditioner.
No.0010577706
Operation & Installation
Manual
CASSETTE
TYPE AIR
CONDITIONER
Please keep this manual carefully and safely.
AB212XCEAA