    CEILING/FLOOR MOUNTING AIR CONDITIONER Operation & Installation Manual AC142ACBEA AC182ACBEA AC242ACBEA AC28NACBEA AC36NACBEA AC42NACBEA AC52NACBEA * No. 0010572479 060113*****5* H Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely
  • Haier AC142ACBEA | User Manual - Page 2
    Contents Cautions 1-2 Safety Precautions 3 Features and Functions 4 Name of Parts 5 Cleaning and Care 6-7 Trouble Shooting 8-9 Operation Tips 10 Installation of Indoor Unit 11-24
  • Haier AC142ACBEA | User Manual - Page 3
    waste materials collecting centers and waste paper disposal services nearest to your house. Safety Instructions and Warnings Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly
  • Haier AC142ACBEA | User Manual - Page 4
    . Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the
  • Haier AC142ACBEA | User Manual - Page 5
    ,52, H07RN-F 5G 4.0mm2. DANGER! Do not attempt to install this air conditioner by yourself. This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the unit. Do not
  • Haier AC142ACBEA | User Manual - Page 6
    the set time is reached, the unit automatically turns off. HEAT & COOL TYPE When the SLEEP button is pressed during Heating mode, the air conditioner's thermostat setting gradually lowers during the period of operation; When the set time is reached, the unit automatically turns off. WIRELESS REMOTE
  • Haier AC142ACBEA | User Manual - Page 7
    4 Power Indicator Lamp 5 OPERATION Indicator Lamp 6 TIMER Indicator Lamp 7 Compressor Run Lamp 8 Intake Grill (Fig.3) 9 Air Filter 10 UP/DOWN Air Direction Flaps 11 RIGHT/LEFT Air Direction Louvers (behind UP/DOWN Air Direction Flaps) for series 36,42,52 for series 28 Note : For the wired control
  • Haier AC142ACBEA | User Manual - Page 8
    Cleaning and Care CAUTION! Before cleaning the air conditioner ,be sure to turn it off and disconnect the Power Supply Cord. Be sure the Intake Grill is installed securely. When removing and replacing the air filters, be sure not to touch the heat exchanger, as personal injury may result. 4. Re-
  • Haier AC142ACBEA | User Manual - Page 9
    air conditioner ,be sure to turn it off and disconnect the Power Supply Cord. Be sure the Intake Grill is installed securely. When removing and replacing the air to your own cleaning and care. For more information, consult authorized service personnel. When cleaning the unit's body, do not use water
  • Haier AC142ACBEA | User Manual - Page 10
    Trouble Shooting Followings are not problems Sound of water flowing is not a problem. During unit operation or at stop, a swishing or gurgling noise may be heard. This noise is generated by refrigerant not restart after stop. Won't start? No outlet air or fan speed can't be changed in dry mode.
  • Haier AC142ACBEA | User Manual - Page 11
    Trouble Shooting Before ask for services, please first check your unit against the following. Air conditioner won't air blows out (in heating mode) Is air conditioner in standby condition in heating mode? If your unit still can't work properly after above mentioned checks, or following problems
  • Haier AC142ACBEA | User Manual - Page 12
    appliance. Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated. Instructions the Cooling, (*) Heating, Dehumidifying, and aircirculation of rooms in
  • Haier AC142ACBEA | User Manual - Page 13
    appliances etc are at least 1 m far away to the indoor unit, outdoor unit, power supply wire, connecting wire, pipes, otherwise images may be disturbed or noises be created. As required, take measures against heavy snow. [Wiring] Air-conditioner (a) Capable of supporting air-conditioner weight, don
  • Haier AC142ACBEA | User Manual - Page 14
    it. After installation, explain correct operation to the customer, according to the operating manual. Let the customer keep this installation manual because it will be used when the room air conditioner is serviced or moved. 1. SELECTING THE MOUNTING POSITION WARNING Install at a place that can
  • Haier AC142ACBEA | User Manual - Page 15
    Installation of Indoor Unit STANDARD PARTS The following installation parts are furnished. Use them as required. ACCESSORIES No. Accessory parts Qty. Remarks 1 Remote controller 1 2 Battery 2 3 Wire clamp Heat 4 insulation sheathing 5 Screw 6 Screw cap Remote 7 controller
  • Haier AC142ACBEA | User Manual - Page 16
    .7 mm 15.88 mm AC242ACBEA AC28NACBEA AC36NACBEA AC42NACBEA AC52NACBEA 9.52 mm 9.52 mm 15.88 mm 19.05mm Maximum length 30 m 30 m 30 m Maximum height (between indoor and outdoor) 20 m 20 m 20 m 50 m 30 m INSTALLATION PROCEDURE Install the room air conditioner as follows: PREPARING INDOOR UNIT
  • Haier AC142ACBEA | User Manual - Page 17
    Installation of Indoor Unit (Fig. 4) (Fig. 5) Wall 10cm 6mm When installing set to wall, install the accessory wall bracket at the position shown in Fig.5,and mount the set to it. Indoor unit outdoor unit 99cm 50cm 24.5cm Wall bracket A 40 B 40 65.5cm 53cm 4.5cm 6.5cm 720mm 147mm 326mm
  • Haier AC142ACBEA | User Manual - Page 18
    720mm 147mm 326mm 247mm 53 85 Installation of Indoor Unit B. UNDER CEILING TYPE Using the installation template, drill holes for piping and anchor bolts(for holes).(Fig.10) (Fig. 10) 900mm A 40 B 40 200mm Installation template Drilling position for anchor bolt Ceilling Wall Drilling
  • Haier AC142ACBEA | User Manual - Page 19
    Installation of Indoor Unit 3. INSTALLING BRACKETS Install the brackets with nuts, washers and spring washers.(Fig. 14) (Fig. 14) Bracket (Left) Bracket (Right) Spring washer Special nut Bracket 4. INSTALLING INDOOR UNIT Reset the hex bolts as shown in Fig.15. (Fig. 15) Indoor unit 68 16 21
  • Haier AC142ACBEA | User Manual - Page 20
    Installation of Indoor Unit (Fig. 17) Remove the hole cover. Arrange the drain hose lower than this portion Drain hose OK NO When drain hose is arranged backward. Secure the drain hose with the VT wire. (Fig. 18) (Fig. 18) Piping hole VT wire hole Drain hose For series 28,36,42,52 VT
  • Haier AC142ACBEA | User Manual - Page 21
    . (Fig. 19) A. Solid wire B. Strand wire Loop Round terminal Strip 25mm Strip 10mm Insulation Screw with special washer Round terminal Terminal Wire board Wire Screw with special washer Round terminal HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD CLAMP After passing the
  • Haier AC142ACBEA | User Manual - Page 22
    Installation of Indoor Unit ELECTRICAL REQUIREMENT Electric wire size and fuse capacity: Table 5 Series Connection cord (mm2) MAX MIN Fuse capacity(A) 14,18 3.5 3.5 2.5 2.5 20 30 24,28 36,42,52 3.5 3.5 2.5 2.0 30 30 ELECTRICAL WIRING CAUTION (1) Match the terminal block numbers
  • Haier AC142ACBEA | User Manual - Page 23
    Installation of Indoor Unit (Fig. 22) Electric component box CAUTION Do not remove the screws. If the screws are removed, the electric component box will fall. Remove the four tapping screws. (2) Pull out the electric component box. (Fig. 23) Electric component box (3) Remove the electric
  • Haier AC142ACBEA | User Manual - Page 24
    AC28NACBEA, AC36NACBEA, AC42NACBEA, AC52NACBEA Note: The meaning of marks "BL" or "B", "BR" or "W" on the terminal block are equal. 060206**** ELECTRICAL WIRING WARNING (1) Always use a special branch circuit and install a special receptacle to supply power to the room air conditioner. (2) Use
  • Haier AC142ACBEA | User Manual - Page 25
    capacity must be the sum of the room air conditioner current and the current of other electrical appliances. When the current contracted capacity is insufficient, change the contracted capacity. (2) When the voltage is low and the air conditioner is difficult to start, contact the power company
  • Haier AC142ACBEA | User Manual - Page 26
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Operation & Installation
Manual
No. 0010572479
H
AC142ACBEA
AC182ACBEA
AC242ACBEA
AC28NACBEA
AC36NACBEA
AC42NACBEA
AC52NACBEA
&EXPOSED CEILING/FLOOR MOUNTING
AIR CONDITIONER
CONVERTIBLE CEILING/FLOOR MOUNTING
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
*
060113
*****5*