    trouble-shooting to the user according to the operation manual. In addition, this installation instruction and operation manuals do such prevention. Leakage of refrigerant exceeding thickness limit can easily structures (e.g. burglarproof net) Installation support of insufficient strength can cause
  • Haier AC162FEBHA | User Manual - Page 3
    fire hazard. Water drainage pipe should be installed according to instructions to ensure smooth discharge of water. In addition, heat air of high humidity. 2.Insulation of metal parts of building and air conditioner should be carried on in compliance with technical standards of electrical appliances
  • Haier AC162FEBHA | User Manual - Page 4
    and take right-side intake barrier down. (AC182,242, 282FEAHA,AC182,242,282FEBHA. Installation of Air Conditioner Installation in under ceiling 1. Installation of suspending bolts Installation of supporting frame for AC092,122,142,162FEAHA, AC092,122,142,162FEBHAtype should be internally suspended
  • Haier AC162FEBHA | User Manual - Page 5
    Machine Bolt sleeve M10 flat washer with double nuts 40mm Supporting fram Hexagon bolt Machine 40mm Supporting frame Space length between suspending bolt and ceiling should be less than 40 mm. (ceiling) (ceiling) of supporting frame (wall) The air conditioner cannot be adjusted horizontally
  • Haier AC162FEBHA | User Manual - Page 6
    ,AC092,122,142,162FEBHA) (1) Fix four rubber footings, 4X16 screw snail, 12 washer on the bottom of the machine (only for floor type). (2) As shown in the wall according right to method prescribed. down (3) Install supporting frame as shown in the diagram below. left drain hose Right Drain
  • Haier AC162FEBHA | User Manual - Page 7
    for air conditioner AC092,122,142,162FEAHA AC092,122,142,162FEBHA AC182,242,282FEAHA AC182,242,282FEBHA Specification of distribution tube Gas side Fluid side Note: Data inside parentheses is wall thickness of copper tube with unit of mm. Air tightness test Evacuation Addition of refrigerant
  • Haier AC162FEBHA | User Manual - Page 8
    tube should be done respectively in fluid and gas side. During refrigeration, temperatures in fluid and gas sides are low. To prevent moisture pipe is less than 20m. If distribution tube is long, a supporting frame should be set to prevent undulation. Aggregative distribution tube is constructed as
  • Haier AC162FEBHA | User Manual - Page 9
    wires. Systems of refrigerant distribution tube and power AC 220230V, 50Hz Manual switch 15A Fuse 15A Power damaged,it must be replaced by the manufacturer or its service agent or a similar qualified person. The wiring method reached. The breaker of the air cinditioner should be all pole switch
  • Haier AC162FEBHA | User Manual - Page 10
    -230V~,50Hz centralized control signal wire earth (centralized controller) Wiring layout of centralized controller should be done according to installaiton manual of centralized controller Operation control Solution of group control One set of remote controller can control a group of 16 indoor
  • Haier AC162FEBHA | User Manual - Page 11
    tube of refrigerant, wires in air conditioner room and drainage pipe after finishing these engineering. 2.Fix them on the wall with supporting frame after wrapping Donít handle horizontal swing leaves manually to prevent defect ouccring. Refer to ìoperation manualî to know how to operate.
  • Haier AC162FEBHA | User Manual - Page 12
    air conditioner run reluctantly but stop after a short while. 3.To protect compressor during start of the machine, switch its power on at time 12 hours in priority to operation. 4.Refer to ìoperation manual of outdoor. It is not a defect if trouble-shooting code ì95î is displayed on remote controller