  • Haier AU48NAIEAA | User Manual - Page 1
    INSTRUCTIONS AU182AEEAA CONTENTS Name of Parts 1 Safety Cautions 2-3 Installation Procedure---------4-13 AU242AGEAA AU282AGEAA AU28NAGEAA AU36NAHEAA AU362AHEAA AU48NAIEAA AU60NAIEAA No.0010577959 B Before using the air conditioner,please read this manual carefully. Please keep this manual
  • Haier AU48NAIEAA | User Manual - Page 2
    of Parts AU182AEEAA Air inlet AU242AGEAA AU282AGEAA AU28NAGEAA Air inlet Air outlet Compressor (Inside of unit) AU36NAHEAA AU362AHEAA Air outlet Compressor (Inside of unit) Air inlet Air outlet Compressor (Inside of unit) Air inlet Air outlet Compressor (Inside of unit) AU48NAIEAA AU60NAIEAA 1
  • Haier AU48NAIEAA | User Manual - Page 3
    INSTRUCTIONS: These information can ensure the correct operation of the machine. Be sure to conform with the following important Safety Cautions. The Safety Cautions should be at hand so that they can be checked at any time when needed. If the conditioner is transferred to the new user, this manual
  • Haier AU48NAIEAA | User Manual - Page 4
    may cause water leak, electrical shock and fire hazard. Don't operate the air-conditioner with damp hands. Otherwise will be shocked. Call the dealer to take measures to prevent the refrigerant from leaking. If conditioner is installed in a small room be sure to take every measure in order
  • Haier AU48NAIEAA | User Manual - Page 5
    the unit. Mount guide-louvers to place where short-circuit is a possibility. When installing several units, secure sufficient suction space to avoid short circuiting. (1) Open space requirement around the unit Air inlet L3 L2 500 Air (Servicing inlet space) Air outlet L1 Note : (1). Fix
  • Haier AU48NAIEAA | User Manual - Page 6
    To fix by bolts AU36NAHEAA AU362AHEAA (a) Concrete foundation Anchor bolt Unit Concrete foundation To fix by bolts AU48NAIEAA AU60NAIEAA (a) Concrete foundation Concrete foundation Anchor bolt (b) Foundation anchor Unit Concrete foundation Anchor bolt (b) Foundation anchor Unit Anchor bolt
  • Haier AU48NAIEAA | User Manual - Page 7
    640 25 680 Installation Procedure (2) Installation sketch of outdoor unit AU182AEEAA 780 Power Wiring Terminal Power Wiring Distribution Hole AU242AGEAA AU282AGEAA AU28NAGEAA 810 Power Wiring Terminal Power Wiring Distribution Hole Installation of outdoor unit 500 580 270 315 288
  • Haier AU48NAIEAA | User Manual - Page 8
    1250 25 380 340 4. Refrigerant piping (1) Outline piping AU182AEEAA Flare connection Indoor unit Gas pipe 3-way stop valve Liquid pipe Flare connection Outdoor unit 2-way stop valve AU242AGEAA AU282AGEAA AU28NAGEAA AU36NAHEAA AU362AHEAA AU48NAIEAA AU60NAIEAA Flare connection Gas pipe 3-way
  • Haier AU48NAIEAA | User Manual - Page 9
    vertical height difference. Model AU182AEEAA AU242AGEAA AU282AGEAA AU28NAGEAA AU36NAHEAA AU362AHEAA AU48NAIEAA AU60NAIEAA One way piping length area for gas leakage. (4) Piping connection Connecting method (indoor unit) Apply refrigerant oil at half union as large and flare nut. To bend a pipe
  • Haier AU48NAIEAA | User Manual - Page 10
    discharging method After finishing connection of refrigerant pipe, it shall perform air tightness test. The air tightness test adopts nitrogen tank to give pressure according to the pipe connection mode as the following figure shown. The gas and liquid valve are
  • Haier AU48NAIEAA | User Manual - Page 11
    the vacuum pump of (lower than -755mmHg)high vacuum degree and large air discharging (over 40l/min). The vacuumizing time depends on the length of AU362AHEAA, AU48NAIEAA, AU60NAIEAA, M=65 Only in COOLING operation can charge the additional refrigerant. When charging, the refrigerant shall be charged
  • Haier AU48NAIEAA | User Manual - Page 12
    wiring standard. The breaker of the air conditioner should be all-pole switch; and replaced by the manufacturer or its service agent or a similar qualified person. drop.) Item Model Circuit breaker Power AU28NAGEAA AU36NAHEAA 3 30 AU48NAIEAA AU60NAIEAA 3 30 26 4.0 40 instruction manual. 11
  • Haier AU48NAIEAA | User Manual - Page 13
    , AU362AHEAA To Indoor Unit Y/G L N 12 3 POWER SUPPLY: 1PH, 220-230V~, 50Hz OUTDOOR UNIT TERMINAL BLOCK FIG.2 For: AU28NAGEAA, AU36NAHEAA, AU48NAIEAA, AU60NAIEAA To Indoor Unit R S TN 1 2 3 Y/G OUTDOOR UNIT TERMINAL BLOCK POWER SUPPLY: 380-400V, 3N~, 50Hz FIG.3 WARNING DO NOT CONNECT THE
  • Haier AU48NAIEAA | User Manual - Page 14
    service valve for gas pipe. Discharge pressure at check joint on the compressor discharge pipe. Temperature difference between return air and supply air further information ). Model Zmax value AU60NAIEAA
  • Haier AU48NAIEAA | User Manual - Page 15
    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P.R.China Web Site: http://www.haier.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

ROOM AIR CONDITIONER
OUTDOOR UNIT
Before using the air conditioner,please read this manual carefully.
Please keep this manual properly for future use.
CONTENTS
Name of Parts----------------------1
Safety Cautions------------------2-3
Installation Procedure---------4-13
INSTALLATION INSTRUCTIONS
No.0010577959
B
AU242AGEAA
AU282AGEAA
AU28NAGEAA
AU48NAIEAA
AU60NAIEAA
AU36NAHEAA
AU362AHEAA
AU182AEEAA