Haier HB3600VD1M22 User Manual

Haier HB3600VD1M22 Manual

Haier HB3600VD1M22 manual content summary:

  • Haier HB3600VD1M22 | User Manual - Page 1
    Installation & Operation Manual Air Handler 13 SEER 2 3 4 5 Ton WARNING WHEN THIS APPLIANCE IS INSTALLED IN AN ENCLOSED AREA, & 90B UNIFORM MECHANICAL CODE READ THESE INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING TO INSTALL OR SERVICE THIS APPLIANCE. ONLY FACTORY AUTHORIZED KITS OR ACCESSORIES SHOULD
  • Haier HB3600VD1M22 | User Manual - Page 2
    Parts Source Installation Requirements Air Flow Orientation Horizontal Left-Hand Instructions Refrigerant Tubing Condensate Removal Electrical Connections Thermostat Wiring Orifice Change Circulating Air Uniform Mechanical Code Prior to shipment, this appliance was tested and inspected for damage at
  • Haier HB3600VD1M22 | User Manual - Page 3
    PHYSICAL DIMENSIONS of 2 Ton D 1" C [2.54 cm] PLASTIC BREAKER COVER B E 11" [29 cm] SUCTION LINE A 3.3" [8.3 cm] PRIMARY & SECONDARY CONDENSATE DRAINS- HORIZONTAL 3/4" NPT F K G 2" [5.1 cm] 1.1" [2.9 cm] LIQUID LINE 2" [5.1 cm] TYPICAL 2.4" [ 6 cm] 1.2" [3 cm] H INLET FRONT
  • Haier HB3600VD1M22 | User Manual - Page 4
    PHYSICAL DIMENSIONS of 3 Ton PLASTIC BREAKER COVER INLET BOTTOM SIDE VIEW ELECTRICAL POWER SUPPLY SUCTION LINE LIQUID LINE LOW VOLT SUPPLY ELECTRICAL POWER SUPPLY 4
  • Haier HB3600VD1M22 | User Manual - Page 5
    PHYSICAL DIMENSIONS of 4,5 Ton PLASTIC BREAKER COVER INLET BOTTOM SIDE VIEW ELECTRICAL POWER SUPPLY SUCTION LINE LIQUID LINE LOW VOLT SUPPLY ELECTRICAL POWER SUPPLY 5
  • Haier HB3600VD1M22 | User Manual - Page 6
    through local distributors.When ordering replacement parts, give the COMPLETE model and serial numbers shown on the rating plate. INSTALLATION REQUIREMENTS Before installing this appliance insure that it is properly sized and adequate power is available. This appliance can be installed in the
  • Haier HB3600VD1M22 | User Manual - Page 7
    applications, and install insulation kit on vertical ( donut shape ) drain pan. *Upflow Discharge *Air Handler is factory ready for Upflow & Horizontal Right Discharge Application for 3*4*5 as shown. *Air Handler is factory ready for Upflow & Horizontal Left Discharge Application for 2 as shown. 7
  • Haier HB3600VD1M22 | User Manual - Page 8
    -HAND INSTRUCTIONS Important: Read instructions below screws. Snap in the drain cover on the right lower service panel. 7) The Airhandler can now be placed in its the user. 9) WARNING: The "A" coil contains 150 p.s.i.g. of air pressure. Before setting up flowrator assembly for field brazing see page
  • Haier HB3600VD1M22 | User Manual - Page 9
    REFRIGERANT TUBING Refrigerant tubing should be installed as to avoid undue stress. They must be supported or routed to avoid terminate at the tubing entrance to the air handler. Do not reduce the recommended tubing size. CONDENSATE REMOVAL THIS APPLIANCE EMPLOYS A DRAW-THROUGH COIL, THEREFORE A
  • Haier HB3600VD1M22 | User Manual - Page 10
    must be placed over the wiring diagram on the air handler. All pertinent information, such as the rating plate, included in the 3/4 WARNING A MEANS OF STRAIN RELIEF MUST BE INSTALLED TO THIS APPLIANCE AT THE ELECTRICAL SERVICE ENTRANCE. When an optional electric heat kit is installed refer to the
  • Haier HB3600VD1M22 | User Manual - Page 11
    SWITCH MODE SWITCH Open for heating Close for cooling control the indoor unit & heat pump outdoor unit at the same time no air supply mode. If need select the air supply mode, switch can adopt multi-connect switch or select switch. The detailed infor see the following diagram TO INDOOR FAN RELAY
  • Haier HB3600VD1M22 | User Manual - Page 12
    different power switch show diagram 5. This mode is control the indoor unit & cooling only outdoor unit at the same time no air supply mode. If need select the air supply mode, switch can adopt multi-connect switch or select switch. The detailed infor see the following diagram 6. TO FAN RELAY
  • Haier HB3600VD1M22 | User Manual - Page 13
    : WARNING THIS COIL IS SHIPPED UNDER PRESSURE. FOLLOW THESE INSTRUCTIONS TO PREVENT INJURY: 1) Remove the 1/4 nut on the Manual "K". The use of flexible duct connectors is recommended to minimize the possibility of noise transmission. These connectors must conform to U.L. standards. Supply air
  • Haier HB3600VD1M22 | User Manual - Page 14
    1800 1745 1690 1635 1580 1525 1850 1795 1740 1685 1630 1575 The air delivery can be varied by changing the blower speeds. This can allow for place. 2) Start the unit in the heat mode. 3) Measure the return air temperature. 4) Measure the supply temperature. This measurement should be done in
  • Haier HB3600VD1M22 | User Manual - Page 15
    be present. Unit is protected from vehicular or other physical damage. Return air is not to be obtained from any areas where there may be objectionable MAINTENANCE WARNING DISCONNECT ALL POWER SUPPLIES BEFORE PERFORMING ANY SERVICE. The only item to be maintained on a regular basis by the
  • Haier HB3600VD1M22 | User Manual - Page 16
    H B 24 00 V D 1 M 20 Haier Nominal capacity in Electric Blower unit Electric heater (000 R 073 078 HC30D1VAR 078 HB3600VD1M22 HR30D1VAR 085 HB3600VD1V22 HC36D1VAR HR36D1VAR 091 085 H C 4 2 D 1 VA R 087 HB4800VD1M22 H R 4 2 D 1 VA R 097 HB4800VD1V22 H C 4 8 D 1 VA R H R 4 8
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

13 SEER
2
3
4
5 Ton
Installation & Operation Manual
Air Handler
G
WARNING
WHEN THIS APPLIANCE IS INSTALLED IN AN ENCLOSED AREA, SUCH AS
A GARAGE OR UTILITY ROOM, WITH ANY CARBON MONOXIDE PRODUCING
DEVICES (i.e. AUTOMOBILE, SPACE HEATER, WATER HEATER,ETC.) INSURE
THAT THE ENCLOSED AREA IS PROPERLY VENTILATED.
WARNING
CARBON MONOXIDE (REFERED TO AS CO) CAN CAUSE PERSONAL INJURY
OR DEATH
WARNING
FAILURE TO FOLLOW THESE INSTRUCTIONS, LOCAL CODES OR NATIONAL
CODES MAY CAUSE FIRE, EXPLOSION, ELECTRICAL SHOCK, PERSONAL
INJURY OR PROPERTY DAMAGE.
FOLLOW ALL LOCAL CODES. IN THE ABSENCE OF LOCAL CODES REFER TO :
NATIONAL ELECTRICAL CODE NFPA 70
NFPA 90A & 90B
UNIFORM MECHANICAL CODE
READ THESE INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING TO INSTALL
OR SERVICE THIS APPLIANCE.
ONLY FACTORY AUTHORIZED KITS OR ACCESSORIES SHOULD BE USED WHEN
INSTALLING OR MODIFYING THIS APPLIANCE, UNLESS OTHERWISE NOTED IN
THESE INSTRUCTIONS.
SOME LOCALITIES MAY REQUIRE THE INSTALLER/SERVICER TO BE LICENSED.
IF IN DOUBT CONTACT YOUR LOCAL AUTHORITIES.
These instructions should be retained and kept adjacent to the unit for future reference.
MODEL #
HB
M20
HB
MODEL #
HB
V20
HB
INSTALLATION DATE
The information contained in this booklet is subject to change without notice.
No.
0010572323
M22
V22