    INSTALLATION MANUAL ROOM AIR CONDITIONER WALL MOUNTED TYPE HSM 09HEK03/R2(DB) HSM 12HEK03/R2(DB) HUM 09HA03/R2(DB) HUM 12HA03/R2(DB) Read this manual before installation Explain sufficiently the operating means to the user according to this manual. NO.001051
  • Haier HSM12HEK03 | User Manual - Page 2
    Gas leakage detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and outdoor units Accessory 4 7 Drain-elbow 1 8 Cover 1 9 Cushion 4 10 1 Pipe supporting plate 11 Connecting cable 1 Optional parts for piping Mark A Parts name Non-
  • Haier HSM12HEK03 | User Manual - Page 3
    the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind piping can be connected with the outdoor unit. Place, where cold air can be spread in a room entirely. Place, nearby a power For 12 6.35mm(1/4") 9.52mm(3/8") 2
  • Haier HSM12HEK03 | User Manual - Page 4
    Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Make
  • Haier HSM12HEK03 | User Manual - Page 5
    Indoor unit 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover
  • Haier HSM12HEK03 | User Manual - Page 6
    operation can not be carried out and will cause defect. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 2. If the fuse on PC board is broken please
  • Haier HSM12HEK03 | User Manual - Page 7
    Outdoor unit 1.Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical
  • Haier HSM12HEK03 | User Manual - Page 8
    (9K) or 10m(12K). The height difference between any two indoor or outdoor units can not be more than 5m. Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according to the following list. Brand new outdoor unit is charged 50g more refrigerant
  • Haier HSM12HEK03 | User Manual - Page 9
    exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a Gas side Pipe diameter( 6.35mm(1/4") 9.52mm(3/8") 12.7mm(1/2") ) Size A(mm) 0.8~1.5 1.0~1.8 1.2~2.0 our customers how to operate through the instruction manual. Check Items for Test Run Put check
  • Haier HSM12HEK03 | User Manual - Page 10
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

INSTALLATION MANUAL
ROOM AIR CONDITIONER
WALL MOUNTED TYPE
NO.001051
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual.
HS
M
12HEK
03/R2(DB)
HS
M
0
9HEK
03/R2(DB)
H
UM
12HA
03/R2(DB)
H
UM
0
9HA
03/R2(DB)