Haier HSU-09HEC03 User Manual

Haier HSU-09HEC03 Manual

Haier HSU-09HEC03 manual content summary:

  • Haier HSU-09HEC03 | User Manual - Page 1
    to the user according to this manual. Necessary Tools for Installation 1.Driver or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and cap 4 7 Cover 1 8 Cushion 4 9 Pipe supporting plate 1 Arrangement of piping directions Rear left Left
  • Haier HSU-09HEC03 | User Manual - Page 2
    12 HSU-09CA2 HSU-12LEA13-F HSU-12CA2 HSU-12HEA03 HSU-12CB2 HSU-05LEA03 HSU-12LEN03 HSU-07LEA03 HSU-09LEN03 HSU-09HEA03 HSU-09LEA13-H HSU-09LEA13-F HSU-09LEA03 HSU-09LEA13-W HSU-12LEA13-M HSU-12LEA03 HSU-09LEB13-H HSU-12LEA13-W HSU-10LEA03-T A=145mm HSU-10LED03-T HSU-09HEC03 HSU-09LEA03-N HSU
  • Haier HSU-09HEC03 | User Manual - Page 3
    replaced by the manufacturer or its service agent or a similar qualified 12 34 Indoor unit HSU-09LEA13-W HSU-09LEA13-F HSU-09CRA03-T HSU-09LEA03-N Outdoor unit HSU-05LEA03 HSU-09LEN03 HSU-07LEA03 HSU-09CA2 HSU-09LEA03 HSU-12LEA13-W 2X0.75mm Indoor unit { power plug HSU-24LA2 HSU-22LEA03 HSU
  • Haier HSU-09HEC03 | User Manual - Page 4
    not enter the pipe. 2.Attaching Drain-Elbow Pipe Diameter ( ) Fastening torque Liquid side 6.35mm(1/4") Liquid side 9.52mm(3/8") Gas side 9.52mm(3/8") Gas side 12.7mm(1/2") Gas side 15.88mm(5/8") 18N.m 40N.m 40N.m 50N.m 60N.m If the drain-elbow is used, please attach it as figure. (Note: Only
  • 1
  • 2
  • 3
  • 4

No.0010515
136
Installation Manual of Room Air Conditioner
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper
12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Explain sufficiently the operating means to the user
according to this manual.
A
B
C
D
E
F
G
Optional parts for piping
Mark
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
The marks from
to
in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
A
G
Attention must be paid to
the rising up of drain hose
more than 5cm
more than 10cm
more than 10cm
A
C
No.
Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Steel nail, cement
Screw
Plastic cap
Cover
Cushion
1
1
2
3
4
5
6
7
8
9
2
1
1
6
4
1
4
1
Number
of
articles
Accessory parts
4X50
4X25
Pipe supporting plate
more than 10cm
more than 60cm
more than 15cm
more than 10cm
D
E
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation