INSTALLATION MANUAL ROOM AIR CONDITIONER WALL MOUNTED TYPE HSU-09HEK03/R2 HSU-12HEK03/R2 Read this manual before installation Explain sufficiently the operating means to the user according to this manual. NO.0010521664 - Haier HSU-09HEK103 | User Manual - Page 2
leakage detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and outdoor units more 1 Drain-elbow 8 Guardring 1 9 Cushion 4 10 1 Pipe supporting plate Arrangement of piping directions Rear left Left Rear right Right Below Optional - Haier HSU-09HEK103 | User Manual - Page 3
HSU-09HEK03/R2 HSU-12HEK03/R2 Fixing of outdoor unit Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter unit. Place, where cold air can be spread in a room 12 6.35mm(1/4") 9.52mm(3/8") 2 - Haier HSU-09HEK103 | User Manual - Page 4
Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Make - Haier HSU-09HEK103 | User Manual - Page 5
,QGRRUXQLW ,QVHUWWKHGUDLQKRVHLQWRWKHGHQWRIKHDWLQVXODWLRQPDWHULDOVRILQGRRUXQLW ,QVHUWWKHLQGRRURXWGRRUHOHFWULFFDEOHIURPEDFNVLGHRILQGRRUXQLWDQGSXOOLWRXWRQWKHIURQWVLGHWKHQ FRQQHFWWKHP &RDWWKHIODULQJVHDOIDFHZLWKUHIULJHUDQWRLODQGFRQQHFWSLSHV - Haier HSU-09HEK103 | User Manual - Page 6
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F 1(L) 2(N) 34 Indoor unit HSU-09HEK03/R2 HSU-12HEK03/R2 Outdoor unit connecting wiring: -mod 09-12: 3G1.0mm2 + 2G0.75mm2 Power cable: - - Haier HSU-09HEK103 | User Manual - Page 7
the threads and cause a leakage of gas. Spanner Torque wrench Pipe Diameter ( ) Fastening torque Liquid side 6.35mm(1/4") Gas side 9.52mm(3/8") Gas side 12.7mm(1/2") 18N.m 42N.m 50N.m Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. When connecting pipe exceeds - Haier HSU-09HEK103 | User Manual - Page 8
35mm(1/4") 2-way valve 3-way valve Open 90o Service port 90ofor 6 sec. Gas Side 9.52mm(3/8") 12.7mm(1/2") 3-way valve If it does not stop . 2-way valve 3-way valve Service port cap Valve rod cap Valve rod cap CAUTION: 1.If the refrigerant of the air conditioner leaks, it is necessary to - Haier HSU-09HEK103 | User Manual - Page 9