    to the user according to this manual. Necessary Tools for Installation 1.Driver detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and hole cover 5 Drain-elbow 1 6 1 Pipe supporting plate more than 10cm Arrangement of piping directions
  • Haier HSU-09RF03 | User Manual - Page 2
    unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind. If vibration may affect the house, fix the unit by attaching a vibration
  • Haier HSU-09RF03 | User Manual - Page 3
    Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Make
  • Haier HSU-09RF03 | User Manual - Page 4
    fixing with adhesive tape Lid for right piping Lid for under piping pipe Heat insulation material Lid for left piping Drain hose Piping Pipe supporting plate Indoor/outdoor electric cable Fix with adhesive tape Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by
  • Haier HSU-09RF03 | User Manual - Page 5
    operation can not be carried out and will cause defect. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F. 2. If the fuse on PC board is broken please change it
  • Haier HSU-09RF03 | User Manual - Page 6
    damage the threads and cause a leakage of gas. Spanner Torque wrench Pipe Diameter Fastening torque Liquid side 6.35mm(1/4") Gas side 9.52mm(3/8") Gas side 12.7mm(1/2") 18N.m 42N.m 55N.m Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. The standard pipe length
  • Haier HSU-09RF03 | User Manual - Page 7
    5.Purging Method:To use vacuum pump Liquid Side 6.35mm(1/4") Gas Side 9.52mm(3/8") 12.7mm(1/2") Detach the service port's cap of 3-way valve, the valve rod's cap for 2-way valve and 3-way's, connect the service port into the projection of charge hose (low) for gaugemanifold. Then connect the
  • Haier HSU-09RF03 | User Manual - Page 8
    heat insulation to it without fail. Check for Installation and Test Run Please kindly explain to our customers how to operate through the instruction manual. Check Items for Test Run Put check mark in boxes Gas leak from pipe connecting? Heat insulation of pipe connecting? Are the connecting
  • Haier HSU-09RF03 | User Manual - Page 9
    Park, No.1 Haier Road, Qingdao, P.R.China IT CONFORMITÀ ALLE DIRETTIVE EUROPEE PER I MODELLI: CE Tutti i prodotti sono conformi alle seguenti normative europee: - Direttiva 73/23/EEC Basso Voltaggio -
  • Haier HSU-09RF03 | User Manual - Page 10
    Industrial Park, No.1 Haier Road, Qingdao, P.R.China ES CONFORMIDAD EUROPEA DE LAS REGULACIONES PARA LOS MODELOS: CE Todos los productos están en conformidad con las siguientes Normativas Europeas: - Bajo
  • Haier HSU-09RF03 | User Manual - Page 11
    Industrial Park, No.1 Haier Road, Qingdao, P.R.China Contains fluorinated greenhouse gases covered by the Kyoto Protocol A R410A 1= 2 2= 1 kg B kg C 1+2= kg D FE IT INFORMAZIONI IMPORTANTI SUL REFRIGERANTE UTILIZZATO Questo prodotto
  • Haier HSU-09RF03 | User Manual - Page 12
    Park, No.1 Haier Road, Qingdao, P.R.China Contains fluorinated greenhouse gases covered by the Kyoto Protocol A R410A 1= 2 2= 1 kg B kg C 1+2= kg D FE ES INFORMACIÓN IMPORTANTE EN RELACIÓN AL REFRIGERANTE UTILIZADO
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

No.00105
1
Installation Manual of Room Air Conditioner
Drawing for the installation of indoor and outdoor units
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper
12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Explain sufficiently the operating means to the user
according to this manual.
Necessary Tools for Installation
The models adopt HFC free refrigerant R410A
A
B
C
D
E
F
G
Optional parts for piping
Mark
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
No.
Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain-elbow
1
1
2
3
4
5
6
2
1
4
1
1
Number
of
articles
Accessory parts
Pipe supporting plate
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
The marks from
to
in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
A
G
Attention must be paid to
the rising up of drain hose
more than 5cm
more than 10cm
more than 10cm
more than 10cm
more than 60cm
more than 15cm
more than 10cm
A
C
D
Screw
Plastic cap
4X25