    HWR10XC5,HWR12XC5 ESA3105,ESA3125 (ESA3105/ESA3125 Only) 0010551962
  • Haier HWR10XC5 | User Manual - Page 2
    English
  • Haier HWR10XC5 | User Manual - Page 3
    English
  • Haier HWR10XC5 | User Manual - Page 4
    English 1 1 2 4 4 5 5 6-7 8-12 8 8-12 13-18 14 14 15-18 19-20 20-21 22
  • Haier HWR10XC5 | User Manual - Page 5
    English Important: Test power plug before each use: 1. Press ìreset ìbutton. 2 . Press ìtest ìbutton, unit should trip. 3. Press ìresetî button again for use . Do not use if above test fail. In the event this device trips , the cause of the malfuncti be corrected before further use of the device .
  • Haier HWR10XC5 | User Manual - Page 6
    English
  • Haier HWR10XC5 | User Manual - Page 7
    English You can run the fan only on not so hot days. The fan can be set to run at 3 speeds (HIGH fan, MED fan, LOW fan)as desired by you. You have 3 levels of Fan Speed to set at your desired comfort level. HIGH, MED and LOW. 24
  • Haier HWR10XC5 | User Manual - Page 8
    English 12. Electrostatic Filter (not all models) The Fresh Air Vent allows the air conditioner to Being constructed of high efficiency purifying recirculate inside air, draw fresh air into the room substance, active carbon fabric, electrostatic fabric, and exhaust stale air to the outside .
  • Haier HWR10XC5 | User Manual - Page 9
    English Remote control and control panel operations
  • Haier HWR10XC5 | User Manual - Page 10
    English Having set the temperature you will set the function of the air conditioner. Every time you press the MODE button, it will change between FAN, COOL, ENERGY SAVER and DEHUM. (See Fig. # 3)
  • Haier HWR10XC5 | User Manual - Page 11
    English Once the function mode is decided you will have to set the fan speed.(See fig. #4 Every time you press the SPEED button, fan speed will change between LOW, HIGH,MED. 1) If you choose the COOL mode you can run the fan in one of the 3 speeds HIGH, MED, LOW. 2) For cool days you may want to run
  • Haier HWR10XC5 | User Manual - Page 12
    English
  • Haier HWR10XC5 | User Manual - Page 13
    CLOSE OPEN Airflow can be adjusted by changing the direction of the air conditioner's louvers. This can also increase the cooling efficiency of the air conditioner. Adjusting Horizontal Air Flow Adjusting Vertical Air Flow Direction Direction Adjusting the Horizontal vane up and down will
  • Haier HWR10XC5 | User Manual - Page 14
    English
  • Haier HWR10XC5 | User Manual - Page 15
    English Parts Parts Supplied Window seal gasket Curtain sash screws 31/32" Basepan angle Frame guide Drain tube Curtain attachment screws 13/32" ìCR2025ì battery Remote control Model: HWR10XC5, HWR12XC5, ESA3105, ESA3125 Leftand right side curtains Top rail
  • Haier HWR10XC5 | User Manual - Page 16
    English Installing Unit into A Window Window Opening Requirements The air conditioner is designed to fit into double or single hung sash type wi units comes with an installation kit that provides adjustable mounting louvers between the sides of the unit, and the window frame. The chart below
  • Haier HWR10XC5 | User Manual - Page 17
    3. Insert the Frame Guide into the bottom of support the weigehnttiroefwidth of sill. Fastenwood strip air conditioner. to sill with at leastthreecountersunk Measure width between window moldings to ensure Instant Mount will fit window mounting air conditioner. models are designed for windows
  • Haier HWR10XC5 | User Manual - Page 18
    eca h s t nih 5 lP as f o eb INSTALL OUTER CASE IN WINDOW Top rail About 5∞ Bottom rail ia a t r n u i c a t r hu tC o b a t rt oA f . ye am wa ar f dnapxE wodniw u hsas wodniw eht isae ip a ecna swercs llird raelc e: k E a Tm O N o T ,evird hguorht swercs 3 esU English
  • Haier HWR10XC5 | User Manual - Page 19
    front panel, and grille. (Don't forget to install the attachment screws before replacing grille) Caution: For security purpose, reinstall screws at cabinet's sides. Important: Because window sash helps keep unit in window, make certain window sash contacts outer case before reinstalling chassis.
  • Haier HWR10XC5 | User Manual - Page 20
    water. The water should be below 40oC(104oF). 5. Rinse off and gently shake off excess water from the filter. Let it d replacing it. DO NOT use your air conditioner without the air filter in place. To clean the front panels or the cabinet DO NOT use harsh chemicals, abrasives, ammonia, chlorine
  • Haier HWR10XC5 | User Manual - Page 21
    air conditioner, after the season, remove the unit from the window as per the installation guide. Repack the unit in its original box and store away. If your unit is installed in a wall or you do not intend t remove it from the window connections. TroubleShooting If air conditioner does not operate
  • Haier HWR10XC5 | User Manual - Page 22
    heat. Redirect the airflow Remove any obstacles. Al doors and windows need to be closed so cool air does not escape the room. Air filter may need cleaning. Unit BTU may be too low for the required cooling area. On extreme hot & humid days air conditioners may take a little longer to cool Vent may be