- Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 1
092623 RevD AquaRite®900 series Electronic Chlorine Generator Owner's Manual Contents Operation 2 Installation 11 Troubleshooting 15 Warranty 18 AQR940 AQR925 Hayward Pool Products 620 Division Street, Elizabeth NJ 07207 Phone (908)-355-7995 www.hayward.com USE ONLY HAYWARD GENUINE - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 2
be followed, including the following: • READ AND FOLLOW ALL INSTRUCTIONS • Use Copper Conductors Only • Disconnect all AC power during terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 3
Operation The AquaRite® 900 series is an automatic chlorine generation system for pool or spa sanitation. The operation requires a low concentration of salt (sodium chloride) in the pool water. These levels are low enough that it normally will not be tasted. The AquaRite automatically sanitizes your - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 4
Water Chemistry The table below summarizes the levels that are recommended by The Association of Pool and Spa Professionals (APSP). The only special requirements for the AquaRite are the salt level and stabilizer. It is important to maintain these levels in order to prevent corrosion or scaling and - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 5
Salt Level Use the chart on page 5 to determine how much salt in pounds or (Kgs) need to be added to reach the recommended levels. Be aware that there may already be salt in your pool from prolonged use of chlorine. Test your pool, then add the correct amount. Use the equations below (measurements - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 6
5 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 7
6 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 8
.) is controlling the AquaRite--the main switch and "Desired Output %" adjustment are inactive. When flashing, the Pro Logic, Intellitouch or Eos is in SERVICE or TIME-OUT mode and the Main Switch and "Desired Output %" adjustment are active. NO FLOW When illuminated, the flow switch has detected no - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 9
To Set Turbo Cell Type Before operation, the AquaRite must be configured for the chlorinator cell that will be used. Your model AquaRite has been packaged with a corresponding Turbo cell. Refer to the following information and steps below to set the Turbo cell type. "t-3" = if using a T-CELL-3, GLX- - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 10
pool water temperatures drops below 50ºF. This is usually not a problem because bacteria and algae stop growing at this temperature. You can the pool automation display/keypad. Refer to the pool automation control instructions for more information. The AquaRite salt display and LED indicators operate - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 11
is necessary. If the "Inspect Cell" LED remains on after a thorough cleaning, the cell may be worn and require replacement. Servicing and Cleaning the AquaRite cell Turn off power to the AquaRite before removing the electrolytic cell. Once removed, look inside the cell and inspect for - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 12
water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of non-copper based algaecide to the pool, per manufacturer's instructions. This ensures a quick, troublefree transfer to the AquaRite system. Mounting the AquaRite Control The AquaRite is contained in a raintight enclosure that is - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 13
Plumbing Ensure that the AquaRite installation does not constitute a cross connection with the local potable water supply. Consult local plumbing codes. The AquaRite is packaged with a Turbo cell, flow switch and cell unions. Refer to page 2 for information about available AquaRite models. The - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 14
Wiring Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and NEC electrical codes. To provide safe operation, the AquaRite must be properly grounded and bonded. Input power for stand alone operation: Wire the AquaRite to the LOAD SIDE of the filter - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 15
to communicate to the AquaRite and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used. Refer to each manufacturer's instructions and the wiring diagrams below for proper wiring connection to the AquaRite. NOTE: There must be only 1 "primary" unit. All other AquaRite units - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 16
PCB. Troubleshooting Visit www.hayward.com for helpful information on operation, maintenance and troubleshooting your AquaRite for 30 seconds, the display will revert back to the standard salt display. Common Problems and Solutions 1. "Power" LED not on Check to make sure either 120VAC or - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 17
2. "Generating" LED flashing The temperature of the pool water is too high or low to operate. You can override this by switching the main switch to SUPER CHLORINATE. The AquaRite will run at maximum output for the remainder of the current pump cycle or 24 hours, whichever comes first. 3. "No - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 18
chlorine at a very high rate and deplete the residual free chlorine. Manually shock the pool if indicated in the directions on the algae treatment. Printed Circuit Board fault has been detected. Call for service. MONTHLY WEEKLY ELECTROLYTIC CHLORINE GENERATOR BASIC POOL MAINTENANCE REQUIREMENTS - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 19
Hayward authorized warranty service center. For more information on authorized service centers please contact the Hayward Technical Service Support Center (61 Whitecap in accordance with the recommendations in the owners manual(s). 5. Problems resulting from tampering, accident, abuse, negligence, - Hayward AQR940 | AquaRite-900-Series-Owners-Manual-092623RevD - Page 20
For further information or consumer technical support, visit our website at www.hayward.com Hayward is a registered trademark and AquaRite, Pro Logic and Aqua Logic are trademarks of Hayward Industries, Inc. © 2019
AquaRite 900 series
Electronic Chlorine Generator
®
AQR940
AQR925
Hayward Pool Products
620 Division Street, Elizabeth NJ 07207
Phone (908)-355-7995
www.hayward.com
092623 RevD
Owner’s Manual
Contents
Operation
..............................
2
Installation
.......................
11
Troubleshooting
..................
15
Warranty
..............................
18
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS