Hayward AQR940 AquaRite-900-Quick-Reference-Guide-092624RevA

Hayward AQR940 Manual

Hayward AQR940 manual content summary:

  • 1
  • 2
  • 3
  • 4

Qu
i
c
k
Re
fe
re
n
ce
G
u
id
e
1. Water Temperature (
within cell
)
Cell size displayed, must match installed cell to ensure proper
operations (including salt calculation)
110 - 130VAC, 2A, 50/60Hz
220 - 250VAC, 1A, 50/60Hz
OR
Display Readings
Average Salt Level (
default
)
2. Cell Voltage (
22-32 VDC
)
3. Cell Amperage (
how well the cell IS or
IS NOT working
)
4. Desired Output % (
% of cell time ON
)
5. Instant Salt (
what system is calculating
for salt during chlorination cycle
)
6. Program Code (
AL 0-5 = product branding
)
7. Main Circuit Board Revision (
r 1.59
)
8. Cell Size (
t -15, t - 9, t - 5 or t - 3)
Cell Amperage (average)
If amperage = 0, the system may not be in a chlorination cycle
If amperage is low check salt level, inspect & clean cell
Pushing diagnostics button changes
from one reading to another
Pushing diagnostics button changes
from one reading to another
t-15 (TCELL940)
3.1 - 8.0 Amps
t-3
1.3 - 4.5 Amps
t-9 (TCELL925)
2.3 - 6.7 Amps
t-5
1.9 - 5.7 Amps
Change Units of Measure
Push Diagnostic button until water temperature
appears on display
If in US Standard: Salt = ppm & temp = Fahrenheit; if in Metric: Salt = g/l & temp = Celsius
While showing temperature, flip main
toggle switch from Auto, up to Super