Hayward Aqua Rite AQR

Hayward Aqua Rite Manual

Hayward Aqua Rite manual content summary:

  • Hayward Aqua Rite | AQR - Page 1
    Electronic Chlorine Generator Operation and Installation Manual AQR G LDLINE CON TROLS www.goldlinecontrols.com
  • Hayward Aqua Rite | AQR - Page 2
    • READ AND FOLLOW ALL INSTRUCTIONS • Use Copper Conductors Only • Disconnect all AC power during electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying . • NOTICE TO USERS: This control product is to be used only in accordance with the directions
  • Hayward Aqua Rite | AQR - Page 3
    Table of Contents OPERATION General 1 Water Chemistry 2 Controls 6 Maintenance 8 INSTALLATION Mounting 10 Plumbing 11 Wiring 12 TROUBLESHOOTING Troubleshooting 14 WARRANTY Warranty 16 Aqua Rite® is a registered trademark of Goldline Controls
  • Hayward Aqua Rite | AQR - Page 4
    95,000 liters). Check local codes for other restrictions. The actual amount of chlorination required to properly sanitize a pool varies due to bather load, rainfall, temperature, and the pool's cleanliness. NOTE: Goldline does not recommend using the Aqua Rite to generate bromine. Aqua Rite chlorine
  • Hayward Aqua Rite | AQR - Page 5
    Spa Professionals (APSP). The only special requirements for the Aqua Rite are the salt level and stabilizer. It is important to maintain these . Be sure to tell the pool store that you are using an Aqua Rite chlorine generator. Saturation index The saturation index (Si) relates to the calcium and
  • Hayward Aqua Rite | AQR - Page 6
    -3400 ppm (parts per million) with 3200 ppm being optimal. If the level is low, determine the number of gallons in the pool and add salt according to the chart on page 4. A low salt level will reduce the efficiency of the Aqua Rite® and result in low chlorine production. A high salt level can cause
  • Hayward Aqua Rite | AQR - Page 7
    Current salt Gallons and (Liters) of Pool/Spa water level 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 32,000 34,000 36,000 38,000 40,000 ppm (30,000) (37,500) (45000) (52,500) (60,000) (67,500) (75,000) (82,500) (90,000) (97,500) (105,000)(112,500)(120,000
  • Hayward Aqua Rite | AQR - Page 8
    (Liters) of Pool/Spa water Current Stabilizer Level (ppm) 8,000 (30000) 10,000 12,000 (37500) (45000) 14,000 (52500) 16,000 (60000) 18,000 (67500) 20,000 (75000) 22,000 (82500) 24,000 (90000) 26,000 (97500) 28,000 30,000 32,000 34,000 36,000 38,000 40,000 (105000) (112500)(120000)(127500
  • Hayward Aqua Rite | AQR - Page 9
    Eos is in SERVICE or TIME-OUT mode and the Main Switch and "Desired Output %" adjustment are active. NO FLOW When illuminated, the flow switch has detected no water flowing and the Aqua Rite has stopped generating chlorine. A flashing LED indicates a 15-60 second time delay period. CHECK SALT When
  • Hayward Aqua Rite | AQR - Page 10
    the desired cell type is displayed. 4. Push the Diagnostic button to exit. Desired Output %" adjustment knob The "Desired Output %" adjustment knob is located in the lower center of the Aqua Rite control panel. This setting is used to control the amount of chlorine the Aqua Rite generates. Raise
  • Hayward Aqua Rite | AQR - Page 11
    control instructions for more information. The Aqua Rite salt display and LED indicators operate as normal, but the main switch and "Desired Output %" dial are disabled. Maintaining the Aqua Rite System To maintain maximum performance, it is recommended that you open and visually inspect the cell
  • Hayward Aqua Rite | AQR - Page 12
    " LED remains on after a thorough cleaning, the cell may be worn and require replacement. Servicing and Cleaning the Aqua Rite cell Turn off power to the Aqua Rite before removing the electrolytic cell. Once removed, look inside the cell and inspect for scale formation (light colored crusty or flaky
  • Hayward Aqua Rite | AQR - Page 13
    in accordance with Local and NEC codes. 120/240 VAC POWER G LDLINE CONTROLS INC. FROM FROM POOL SPA TO TO SPA POOL Preparing Pool/Spa Water Refer to page 1 for recommended chemical levels. The pool's chemistry must be balanced BEFORE activating the Aqua Rite®. NOTE: If the pool does not
  • Hayward Aqua Rite | AQR - Page 14
    the local potable water supply. Consult local plumbing codes. The Aqua Rite is packaged with a flow switch and cell unions. The cell must be purchased separately. Refer to page 1 for information about available chlorinator cells. The flow switch and cell should be plumbed in the return line to the
  • Hayward Aqua Rite | AQR - Page 15
    must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and NEC electrical codes. To provide safe operation, the Aqua Rite® must be properly grounded and bonded. Input Power For stand alone operation: Wire the Aqua Rite to the LOAD SIDE of the filter pump timer
  • Hayward Aqua Rite | AQR - Page 16
    power for use with Goldline, Pentair and Polaris controls Wire the Aqua Rite® DIRECTLY to 120/240VAC power (not through timer or relay). GOLDLINE, PENTAIR or POLARIS AQUA RITE (240 VAC) AQUA RITE (120 VAC) SUBPANEL GND GND NEUTRAL GROUND PCB BONDING LOOP PCB BONDING LOOP Optional Goldline
  • Hayward Aqua Rite | AQR - Page 17
    on PCB Eos Troubleshooting Visit www.goldlinecontrols.com for helpful information on operation, maintenance and troubleshooting your Aqua Rite® Electronic Chlorine Generator. Diagnostic Displays Sequential pushes of the small "diagnostic" button next to the LCD display will cause the Aqua Rite to
  • Hayward Aqua Rite | AQR - Page 18
    (below 2400 ppm, Check Salt LED on). - Salt level too high (High Salt LED on). - Very warm pools increase chlorine demand--increase Output %, or filter run time. - Cold water (below 50ºF) causes Aqua Rite to stop generating (Generating LED flash- ing). - Excessive scaling on cell. - High level
  • Hayward Aqua Rite | AQR - Page 19
    LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of
  • Hayward Aqua Rite | AQR - Page 20
    ELECTROLYTIC CHLORINE GENERATOR BASIC POOL MAINTENANCE REQUIREMENTS TEST IDEAL RANGE ADJUSTMENT REQUIRED Free Chlorine pH Cell inspect & clean Refer to section in manual. Questions? Refer to www.goldlinecontrols.com for latest manual revisions, additional information and helpful service
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

www.goldlinecontrols.com
LD
C
G
LINE
ON TROLS
Electronic Chlorine Generator
Operation and Installation
Manual
AQR