    Shown with optional AQL-CHEM Chemistry Kit Electronic Chlorine Generator Operation and Installation Manual AQR-PRO G LDLINE CON TROLS www.goldlinecontrols.com
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 2
    INSTRUCTIONS • READ AND FOLLOW ALL INSTRUCTIONS • Use Copper Conductors Only • Disconnect allAC power during installation. • A green colored terminal service panel with a continuous copper wire equivalent in size to the circuit NOTICE TO USERS: This control product is to be used only in accordance with
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 3
    Table of Contents OPERATION General 1 Water Chemistry 2 Controls 6 Information Menu 7 Settings Menu 9 Operation 11 Maintenance 12 INSTALLATION Mounting 13 Plumbing 14 Wiring 15 TROUBLESHOOTING Troubleshooting 18 WARRANTY Warranty 20
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 4
    pools up to 25,000 gallons (95,000 liters). Check local codes for other restrictions. The actual amount of chlorination required to properly sanitize a pool varies due to bather load, rainfall, temperature, and the pool's cleanliness. Aqua Rite Pro chlorine generators operating with software
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 5
    Professionals (APSP). The only special requirements for the Aqua Rite Pro are the salt level and stabilizer. It is important to maintain these Be sure to tell the pool store that you are using an Aqua Rite Pro chlorine generator. Saturation index The saturation index (Si) relates to the calcium and
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 6
    2700-3400 ppm (parts per million) with 3200 ppm being optimal. If the level is low, determine the number of gallons in the pool and add salt according to the chart on page 4. A low salt level will reduce the efficiency of the Aqua Rite Pro and result in low chlorine production. A high salt level can
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 7
    Current salt Gallons and (Liters) of Pool/Spa water level 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 32,000 34,000 36,000 38,000 40,000 ppm (30,000) (37,500) (45000) (52,500) (60,000) (67,500) (75,000) (82,500) (90,000) (97,500) (105,000)(112,500)(120,000
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 8
    (Liters) of Pool/Spa water Current Stabilizer Level (ppm) 8,000 (30000) 10,000 (37500) 12,000 (45000) 14,000 (52500) 16,000 (60000) 18,000 (67500) 20,000 (75000) 22,000 (82500) 24,000 (90000) 26,000 (97500) 28,000 30,000 32,000 34,000 36,000 38,000 40,000 (105000) (112500)(120000)(127500
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 9
    : When in STOP mode, the Aqua Rite Pro is prevented from energizing the electrolytic cell. In this position there is no chlorine generation. NOTE: To service any of the pool equipment or the Aqua Rite Pro, the power must be turned off at the circuit breaker. SUPER CHLORINATE: (if optional AQL-CHEM
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 10
    , the flow switch must be detecting flow, the chlorinator setting must be set greater than 0%, the water temperature at the cell must be between 50ºF and 140ºF, and the salt level must be within the operating range. If any of these conditions are not met, the chlorinator diagnostic display will tell
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 11
    you will need to inspect the Aqua Rite Pro chlorinator cell approximately every 3 months and clean the cell if necessary. The Aqua Rite Pro will automatically remind you and display "Inspect Cell, hold + to reset" as part of the rotating Information Menu. Clean the cell and then press the "+" button
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 12
    System Low Salt Function depends on displayed menu item Move to next Check System condition or previous/next menu item Refer to the Troubleshooting section for information about error conditions and possible causes. Settings Menu The Settings Menu is used to configure the Aqua Rite Pro and adjust
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 13
    . Slow response, increased need to calibrate, and inconsistent readings are indications that the probes need to be cleaned (see AQL-CHEM manual). Units Metric Toggle between Metric and English Move to previous/next menu item The Aqua Rite Pro can display temperature and units in Metric (ºC and
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 14
    , there are three factors that you can control which directly contribute to the amount of chlorine the Aqua Rite Pro will generate: 1. filter run time each day (hours) 2. the desired output % setting or ORP setting (when using AQL-CHEM) 3. the amount of salt in the pool The filter pump timer should
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 15
    to get "out of balance", the cell may require periodic cleaning. Servicing and Cleaning the Aqua Rite Pro Cell Turn off power to the Aqua Rite Pro before removing the electrolytic cell. Once removed, look inside the cell and inspect for scale formation (light colored crusty or flaky deposits) on
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 16
    performed in accordance with Local and NEC codes. 120/240 VAC POWER AQUA RITEpro FROM FROM POOL SPA TO TO SPA POOL Preparing Pool/Spa Water Refer to page 2 for recommended chemical levels. The pool's chemistry must be balanced BEFORE activating the Aqua Rite Pro. NOTE: If the pool does not
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 17
    to the AQL-CHEM manual for specific mounting instructions. Plumbing Ensure that the Aqua Rite Pro installation does not constitute a cross connection with the local potable water supply. Consult local plumbing codes. The Aqua Rite Pro is packaged with a flow switch and cell unions. The cell must be
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 18
    allow chlorination of both the pool and spa during spillover but preventing overchlorination when operating the spa only. Wiring Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and NEC electrical codes. To provide safe operation, the Aqua Rite Pro
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 19
    these connections. Flow Switch Connector Cell Connector Optional AQL-CHEM Chemistry Kit Plug the connector from the AQL-CHEM into the designated connector on the Aqua Rite Pro PCB as shown below. For detailed installation and operation information, refer to the AQL-CHEM instructions. Connector for
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 20
    RED 1 BLK 2 YEL 3 GRN 4 NOTE: Primary/Secondary jumper is located underneath small circuit board. green yellow bl ack red 4 GRN 3 YEL 2 BLK 1 RED Aqua Rite Optional pH Dispense Wiring Requires the use of a Goldline AQL-CHEM sensing device and an AQL-CHEM2, AQLCHEM2-240 or other pH dispensing
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 21
    + to reset" as part of the rotating Default Menu. Clean the cell (see instructions, page 12) and then press the "+" button during the "Inspect Cell" display to reset the timer. • Low Salt/Minerals or Very Low Salt/Minerals -- When the salt is too low the Aqua Rite Pro will generate less chlorine and
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 22
    Chlorinator Cell Sensor -- The cell sensor is either an open or short circuit. • Low Volts -- If the chlorinator cell voltage is too low. • No Cell Power -- If no chlorinator cell power is detected on the printed circuit board. • Check Flow Switch -- If the flow switch input is invalid. • Cell Power
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 23
    LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of
  • Hayward Aqua Rite | AQ-RT-PRO Oct 08 & later - Page 24
    ELECTROLYTIC CHLORINE GENERATOR BASIC POOL MAINTENANCE REQUIREMENTS TEST IDEAL RANGE ADJUSTMENT REQUIRED Free Chlorine pH Cell inspect & clean Refer to section in manual. Questions? Refer to www.goldlinecontrols.com for latest manual revisions, additional information and helpful service
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Electronic Chlorine Generator
www.goldlinecontrols.com
LD
C
G
LINE
ON TROLS
Shown with optional AQL-CHEM Chemistry Kit
Operation and Installation
Manual
AQR-PRO