Hayward E-Command 4 Model: ALL MODELS Installation - Page 25
Valve3 Function, Valve3 Interlock, Valve3 Freeze Protection
View all Hayward E-Command 4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Valve3 Config. + to view/change Push to access Valve3 options Move to previous/next configuration menu Valve3 Function Solar Rotates between Timeclock (default), Solar, In-floor Cleaner, Filter, Lights, Aux1 and Aux2 Move to next menu item for all functions except solar and super chlorinate Valve3 Interlock Toggle between Enabled and Disabled (default) Valve3 Interlock Disabled Move to next menu item for all functions except super chlorinate Valve3 Freeze Toggle between Enabled and Disabled (default) Valve3 Freeze Disabled Move to previous/next configuration menu only if filter pump is set to variable and relay type is set to standard Valve3 Pump Spd Settings Menu Select between Settings Menu (default) and the desired pump speed Move to previous/next configuration menu Valve3 Function Timeclock (default) - the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see Operations Manual). Solar - the valve operates when the filter pump is running and solar heat is available and the water is less than the desired temperature setting. Solar heating must be enabled in the "Solar Config. menu for proper operation to occur. In-Floor Cleaner - the valve switches the water returning to the pool between the in-floor cleaner and the normal return jets which facilitate efficient surface skimming. The valve will operate the in-floor cleaner for the first half of each clock hour and then switch to the jets/ skimming for the last half of the hour. Valve3=Filter - the valve operates whenever the Filter relay is on. Valve3=Lights - the valve operates whenever the Lights relay is on. Valve3=Aux1 - the valve operates whenever the Aux1 relay is on. Valve3=Aux2 - the valve operates whenever the Aux2 relay is on. Valve3 Interlock If "Enabled", this feature will override the function (timeclock or in-floor cleaner) selected above and turn the valve off when: the filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime and get water flowing), or for the first 3 minutes after solar turns on (allows air in the solar panels to be purged). Interlock is not available for solar or super chlorinate. Valve3 Freeze Protection This function protects the pool and plumbed equipment against freeze damage. If Freeze Protection is enabled and the AIR temperature falls sensor falls below the selected freeze temperature threshold, the ECOMMAND 4 will turn on the valve to allow circulation of the water. IMPORTANT: this only enables operation of the valve3 output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. 22